===================== Product Identification =====================
MSDS NAME:METAL MOVER
NIIN:00N067043
MSDS Number: CBFHC
=== Responsible Party ===
Company:MISTIC METAL MOVER INC
Address:RR#2
City:PRINCETON
State:IL
ZIP:61356
Country:US
Info Phone Num:815-875-1097
Emergency Phone Num:815-875-1097
CAGE:OO209
=== Contractor Identification ===
Company:MISTIC METAL MOVER INC
Box:UNKNOW
CAGE:MXSTC
Company:MISTIC METAL MOVER INC.
Address:1160 N 6TH ST
Box:City:PRINCETON
State:IL
ZIP:61356
Country:US
Phone:815-875-1097
CAGE:OO209
============= Composition/Information on Ingredients =============
Name:ETHANE, 1,1,1-TRICHLORO-; (111 TRICHLOROETHANE) (SARA 313)
(CERCLA)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: >75%
OSHA PEL:350 PPM
ACGIH TLV:350 PPM/450STEL;9495
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATERIALS HAVE PRODUCED
SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LABORATORY
ANIMALS AND COULD HAVE A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS
(EG, EPINEPHRINE) MAY BE CONTRA-INDI CATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO
CHLOROCARBONS . (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:ACUTE:SKIN:MOD IRRIT, DEFAT, DERM.
EYES:IRRIT, REDNESS, TEARING, BLURRED VISION. BRTHG, IN EXCESSIVE
FORM, VAPS CAN CAUSE DIZZ, WEAK, FATIGUE, NAUS, HDCH. INGEST:CAN
CAUSE NAUS & VOMIT. CHRON IC:OVEREXP OF THIS MATL HAS BEEN
SUGGESTED AS CAUSE OF CARDIAC ABNORMALITY, LIVER ABNORMALITY,
KIDNEY DMG. (SUPDAT)
Medical Cond Aggravated by Exposure:NONE KNOWN IF PROPER CONTROL
MEASURES ARE USED.
======================= First Aid Measures =======================
Eyes: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. SKIN: REMOVE CLOTHING UNTIL DRY, WASH WITH MILD SOAP AND
WATER. INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING IS
DIFFICULT. GET MEDICAL ATTENTION. DO NOT GIVE STIMULANTS.
INGESTION: DO NOT INDUCE VOMITTING. CALL A PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Lower Limits:7.5%
Upper Limits:15%
Extinguishing Media:WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROT EQUIPMENT . WATER MAY BE USED TO KEEP FIRE-EXPOSED
CONTAINERS COOL UNTIL FIRE IS OUT. (SUPDAT)
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE . PRODUCT DOES NOT PRESENT ANY FIRE HAZ,
HOWEVER, WHEN CONCENTRATED VAPORS ARE EXPOSED (SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL SPILL: USE ABSORBANT MATERIAL AND
TRANSFER TO OUTDOORS OR HOOD. LARGE SPILL: WEAR PROTECTIVE
EQUIPMENT ONLY, STOP SPILL, PUMP LIQUID TO SALVAGE IF POSSIBLE. USE
ABSORBANT MATERIAL AND SHOVEL INT O A CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:EMPTY CONTAINERS MAY BE HAZARDOUS AND
ALL PRECAUTIONS PREVIOUSLY INDICATED SHOULD BE OBSERVED.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES/HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE FORMATION OF HCL &/OR PHOSGENE . OVEREXP IN ANY
FORM MAY BE H EALTH HAZARD, IN ALL CASES GET MED ATTN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:A NIOSH/MSHA APPROVED AIR RESPIRATOR IF NORMAL
CONDITIONS EXCEED TLV (350 PPM).
Ventilation:LOCAL EXHAUST: USE SUFFICIENT TO KEEP EXPOSURE BELOW TLV.
MECHANICAL (GENERAL): SEE LOCAL.
Protective Gloves:POLYVINYL, ALCOHOL, POLYETHENE.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . NONE REQUIRED DURING NORMAL USE.
Work Hygienic Practices:USE W/ADEQUATE VENT. AVOID PROLONGED BREATHING
OF VAPORS, PROLONGED & REPEATED CONTACT W/SKIN, DO NOT TAKE
INTERNALLY.
Supplemental Safety and Health
FIRE FIGHT PROC: PRODUCT WILL NOT SUSTAIN COMBUSTION. EXPLO HAZ: TO
OPEN FLAMES, ELECTRIC ARCS, IRRITATING AND TOXIC GASES (HCL) MAY BE
FORMED. EFTS OF OVEREXP: SIGNS AND SYMPTOMS OF EXPOSURE: NONE KN
OWN IF PROPER CONTROL MEASURES ARE USED.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>161F,>72C
Vapor Pres:100 @ 68F
Vapor Density:4.5
Spec Gravity:1.324 (H*2O =)
Evaporation Rate & Reference:2.60 (BUTYL ACETATE = 1)
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR LIQUID, AROMATIC ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
WATER, ALUMINUM, MAGNESIUM, POLYCARBONATE, PLASTICS, POLYSTYRENE WILL
DISSOLVE.
Stability Condition to Avoid:WELDING ARCS, OPEN FLAMES, OR OTHER HIGH
TEMPERATURE SOURCES.
Hazardous Decomposition Products:HYDROGEN CHLORIDE (HCL) AND SMALL
AMOUNTS OF PHOSGENE AND CHLORINE.
==================== Disposal Considerations ====================
Waste Disposal Methods:SALL VOLUME: ALLOW TO EVAPORATE. LARGE VOLUME:
RECYCLE, RECLAIM WHERE FEASIBLE. INCINERATE WITH OFF GAS SCRUBBER.
ABSORBED MATERIAL MAY BE DEPOSITED IN ACCORDANCE TO LOCAL, STATE, &
FEDERAL LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|