Search   
MSDS  
:
 ALKALINE BATTERIES-ULTRA-LOW MERCURY
CAS  
:
 1313-13-9
7440-66-6
7440-44-0
7439-97-6
NAME  
:
 manganese dioxide
zinc
potassium hydroxide
carbon
mercury ,0.025%
=====================  Product Identification  =====================

MSDS NAME:ALKALINE BATTERIES-ULTRA-LOW MERCURY
NIIN:00N091599
Status Code:A
MSDS Number: CJMZG
=== Responsible Party ===
Company:B & P CONSORT INC
Address:14839 N W GOLD FINCH LN
Box:4851
City:BREMERTON
State:WA
ZIP:98312
Country:US
Info Phone Num:360-710-6811
Emergency Phone Num:608-275-4856
Preparer's Name:MARSHEL BEASON JR
CAGE:1E2N7
=== Contractor Identification ===
Company:B & P CONSORT INC
Address:14839 N W GOLD FINCH LN
Box:4851
City:BREMERTON
State:WA
ZIP:98312
Country:US
Phone:360-710-6811
CAGE:1E2N7

=============  Composition/Information on Ingredients  =============

Name:MANGANESE DIOXIDE
CAS:1313-13-9
RTECS #:OP0350000
Minumum % Wt:32.
Maxumum % Wt:38.
OSHA PEL:C5 MG/M3
ACGIH TLV:5 MG/M3

Name:ZINC
CAS:7440-66-6
RTECS #:ZG8600000
Minumum % Wt:11.
Maxumum % Wt:16.
ACGIH TLV:124.0 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:POTASSIUM HYDROXIDE
Minumum % Wt:5.
Maxumum % Wt:9.
ACGIH TLV:2.0 MG/M3

Name:CARBON
CAS:7440-44-0
RTECS #:FF5250000
Minumum % Wt:3.
Maxumum % Wt:5.
ACGIH TLV:3.0 MG/M3

Name:MERCURY ,0.025%
CAS:7439-97-6
RTECS #:OV4550000
< Wt:.02
OSHA PEL:see Table Z-2
ACGIH TLV:0.025 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:NONE, UNLESS BATTERY RUPTURES (SEE
    FIRST AID PROCEDURES). THRESHOLD LIMIT VALUE (TLV) AND SOUCRE: N/A.
    CHRONIC:  NOTE:  MERCURY APPEARS ON THE NAVY LIST OF OCCUPATIONAL
    CHEMICAL REPRODUCTIVE HAZARDS.   SEEK CONSULTATION FROM APPROPRIATE
    HEALTH PROFESSIONALS CONCERNING LATEST HAZARD LIST INFO AND SAFE
    HANDLING AND EXPOSURE INFORMATION .
Effects of Overexposure:SEE HEALTH HAZARDS.

=======================  First Aid Measures  =======================

First Aid:SKIN AND EYES: IN THE EVENT THAT BATTERY RUPTURES, FLUSH WITH
    COPIOUS QUANTITIES OF WATER FOR AT LEAST 15 MINUTES. GET IMMEDIATE
    MEDICAL ATTENTION FOR EYES. WASH SKIN WITH SOAP AND WATER.	INHAL: 
    REM OVE TO FRESH AIR.  SUPPORT BREATHING (GIVE O*2/ARTF RESP) . 
    INGEST:  CALL MD IMMED .

=====================  Fire Fighting Measures  =====================

Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:IN BULK STORAGE AREAS , USE FOAM OR DRY POWDER.
    WATER MAY CAUSE ELECTRICAL SHORTS.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT  TO AVOID INHALATION OF HAZARDOUS DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:LIKE ANY SEALED CONTAINER, BATTERY CELLS
    MAY RUPTURE WHEN EXPOSED TO EXCESSIVE HEAT; THIS COULD RESULT IN
    THE RELEASE OF CORROSIVE MATERIALS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:IN THE EVENT OF BATTERY RUPTURE, COLLECT ALL
    RELEASED MATERIAL IN PLASTIC BAG FOR WASTE DISPOSAL. REPORTING
    PROCEDURE: REPORT ALL SPILLS IN ACCORDANCE WITH STATE AND LOCAL
    REGULATIONS. INDIVIDUAL CELL S DO NOT CONTAIN REPORTABLE QUANTITIES
    OF ANY SUBSTANCE ON SARA OR CERCLA LISTS. EXEMPT UNLESS OVER 4,000
    POUNDS OF BATTERIES ARE KNOWN TO HAVE BEEN SOMEHOW OPENED TO
    ENVIRONMENT.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A DRY PLACE. STORING
    UNPACKAGED CELLS TOGETHER SO CONTACTS CAN TOUCH COULD RESULT IN
    CELL SHORTING AND HEAT BUILD-UP. DO NOT RECHARGE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:AS IN ANY FIRE SITUATION, USE NIOSH APPROVED
    SELF-CONTAINED BREATHING APPARATUS (SCBA).
Ventilation:LOCAL EXHAUST, MECHANICAL (GENERAL), SPECIAL, OTHER: NOT
    APPLICABLE.
Protective Gloves:NOT APPLICABLE. IMPERVIOUS GLOVES .
Eye Protection:NOT APPLICABLE. ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT APPLICABLE. ANSI APPROVED EMERGENCY
    EYEWASH AND DELUGE SHOWER .
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:@ 760 MG HG (C): NA
Vapor Pres:MG HG AT 25C: NA
Vapor Density:NA (AIR=1)
pH:NA
Evaporation Rate & Reference:NA (BUTYL ACETATE =1)
Solubility in Water:NA (% BY WEIGHT)
Appearance and Odor:NOT APPLICABLE.
Percent Volatiles by Volume:NA

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID ELECTRICAL SHORTING.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:OXIDES OR FUMES OF MANGANESE, ZINC,
    POTASSIUM, AND MERCURY.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WHEN SHREDDED PER TOXICITY CHARACTERISTIC
    LEACHATE PROCEDURE PARAMETERS AND TESTED PER SW646, 3RD EDITION,
    "TEST METHODS FOR EVALUATING SOLID WASTE" INDEPENDENT CERTIFIED
    LABORATORY ANALYSES HAVE INDI CATED THESE RAYOVAC BATTERY TYPES TO
    HAVE NO HAZARDOUS WASTE CHARACTERISTICS (PER 40 CFR, PART 261.2 4).

===================  MSDS Transport Information  ===================

Transport Information:DO NOT PACK, STORE, OR SHIP USED BATTERIES IN
    METAL OR TIGHTLY SEALED CONTAINERS. THE SLOW EVOLUTION OF HYDROGEN
    GAS FROM USED BATTERIES MAY PRODUCE CONTAINER OVER-PRESSURE OR
    EXPLOSIVE CONDITIONS.

=====================  Regulatory Information  =====================

SARA Title III Information:NOTIFICATION IS NOT REQUIRED BECAUSE THESE
    PRODUCTS ARE ARTICLE(S) THAT DO NOT RELEASE A COVERED TOXIC
    CHEMICAL UNDER THE NORMAL CONDITIONS OF PROCESSING OR USE.
Federal Regulatory Information:WE WOULD LIKE TO INFORM MFR'S CUSTOMERS
    THAT THESE BATTERIES ARE EXEMPT ARTICLES AND ARE NOT SUBJECT TO THE
    29CFR 1910.1000 OSHA REQUIREMENT, AND THE MSDS ARE SUPPLIED AS A
    SERVICE TO YOU.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
ROYCO 49B 64742-57-0
68953-58-2
1317-33-5
7632-00-0
25619-56-1
ROCHEZ SOLAR ROCK WATER TREATMENT CRYSTALS
ALUMINA OXIDES FOR CHROMATOGRAPHY, ALKALINE 1344-28-1
1313-59-3
60676-86-0
1309-37-1
7732-18-5
BATTERY ELECTRIC STORAGE 7439-92-1
BATTERY ELECTRIC STORAGE 7439-92-1
PLSB7-2X, PLASMA STANDARD 1,000 PPM OF (SUPDAT) 87-69-4
1332-81-6
7732-18-5
AQDEX WB URE GL BLK 595B-17038, 9009W103 872-50-4
84-74-2
PLSB7-2T,PLASMA STANDARD 1,000 PPM OF (SUPDAT) 87-69-4
LC-01, OPTICAL LEN CLEANER TYPE 1 68412-54-4
7732-18-5
64-17-5
DMF 68-12-2
TOLUENE 108-88-3
IN 15PA INDIUM IN-111 OXYQUINOLINE 7440-74-6
ATROPINE SULFATE INJECTION USP 55-48-1
ATA 101AL CONVENTIONAL POWDER ATOMIZED ALUMINUM POWDER 7429-90-5
8023370 4166 BLACK/WHITE 8001-78-3
2530-83-8
85-42-7
71-36-3
126-73-8
78-40-0
S1575 CALIBRATION SOLUTION PH 6.8 CODE 943-792 26172-55-4
2682-20-4
H2002E HURN-SAFE ELECTRONICS CLEANER 111-76-2
S1565 CALIBRATION SOLUTION PH 7.4 CODE 943-791 26172-55-4
2682-20-4
77288 V-700 68909-79-5
SUPER SUPREME TRAFFIC PAINT RED, STRD2R 67-64-1
111-76-2
106-97-8
108-65-6
74-98-6
108-88-3
64742-89-8
1330-20-7
75-28-5
100-41-4
7727-43-7
12656-85-8
SUPER SUPREME TRAFFIC BLACK PAINT, STBK2R 67-64-1
111-76-2
106-97-8
1333-86-4
75-28-5
8032-32-4
74-98-6
108-88-3
64742-89-8
1330-20-7
100-41-4
11831301, 2.0 POUR ( COMPONENT A) 101-68-8
9016-87-9
CIRCUITWORKS CONDUCTIVE PEN, CW2200MTP 7440-22-4
108-65-6
112-07-2
123-86-4
PLSB7-2T PLASMA STANDARD 1,000 PPM OF (SUPDAT) 87-69-4
1332-81-6
7732-18-5
ENPLATE CU-406B 7732-18-5
1310-73-2
151-50-8
MICROPOLISH II 0.05 MICRON, 40-6325-008/016/080 1344-28-1
B75HW1008. BUILDERS FINEST INTERIOR LATEX FLAT (SUP DAT) 107-21-1
14464-46-1
12001-26-2
471-34-1
13463-67-7
CLAY DRAIN PIPE 513-77-9
14808-60-7
11831301, 2.0 POUR (COMPONENT B) 85-68-7
REPRO 10 B SIDE 101-68-8
MASTER DISC CEMENT 7732-18-5
7664-41-7
9003-31-0
PRO LINE SUPREME INTERIOR LATEX FLAT, 70-1000 BRIGHT WHITE 107-21-1
14808-60-7
14464-46-1
12001-26-2
471-34-1
13463-67-7
1333-86-4
ANTI-FREEZE COOLANT 107-21-1
7732-18-5
11750-XX BOUINS FIXATIVE SOLUTION 50-00-0
64-19-7
88-89-1
7732-18-5
DO-IT BEST LATEX INTERIOR FINISH VELVET, W56A708 NEUTRAL BAS 112-34-5
107-21-1
14808-60-7
471-34-1
13463-67-7
7732-18-5
TICONIUM PREMIUM 100 DENTURE ALLOY REGULAR 7440-47-3
7440-02-0
7439-98-7
7439-96-5
7429-90-5
7440-41-7
D1210 REDECAL 6381-92-6
7647-01-0
7732-18-5
CAN01 27813-02-1
STAINAWAY, 14845 9016-45-9
AC401160020, AMMONIUM PERSULFATE, REAGENT ACS, (SUPDAT) 7727-54-0
PLSB7-3Y,PLASMA STANDARD 1,000 PPM OF (SUPDAT) 87-69-4
1332-81-6
7732-18-5
TRI-FLOW LUBRICANT-LIQUID 628-63-7
61790-48-5
34590-94-8
557-21-1
PLSB7-3X,PLASMA STANDARD 1,000 PPM OF (SUPDAT) 87-69-4
1332-81-6
7732-18-5
AC401160100, AMMONIUM PERSULFATE, REAGENT ACS, (SUPDAT) 7727-54-0
CASCOPHEN G-4422A, 321792 50-00-0
67-56-1
108-46-3
108-95-2
MS-222N AERO-DUSTER 811-97-2
ALKALINE BATTERIES-ULTRA-LOW MERCURY 1313-13-9
7440-66-6
7440-44-0
7439-97-6
FLOURESCENT 1505 YELLOW ORANGE, 1325 8052-41-3
64741-41-9
M-O-NC BLACK, ME1009 80-05-7
112-15-2
68186-91-4
6484 MICROTAINER BRAND TUBE W/LITHIUM HEPARIN 9045-22-1

Free MSDS Search ( Providing 250,000+ Material Properties )