PRODUCT: CERAMALUX鈩? HPS with ALTO鈩AMP TECHNOLOGY
1000 WATT Including Non-Cycling
SECTION 1: MANUFACTUERER
Manufacturer鈥檚 Name and Address: Philips Lighting Company
A Division of Philips Electronics
North America Corporation
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875
Emergency Telephone Number: (800) 424-9300 CHEMTREC
(732) 563-3197 Safety and Compliance
Other Information Calls: (607) 776-3311 Ext. 300
SECTION 2: HAZARDOUS INGREDIENTS
OSHA PEL ACGIH PERCENTAGE
Barium (7440-39-3) 8-hr TWA 0.5 mg/m3 .5mg/m3 <400 ppm
Sodium (7440-23-5) 8-hr TWA 2.0 mg/m3 ceiling 2 mg/m3 <10 ppm
Silver (7440-22-4) 8-hr TWA 0.01 mg/m3 TWA 0.1 mg/m3 <30 ppm
Mercury (7439-97-6) .1 mg/m3 .025 mg/m3 .01%
Copper (7440-50-8) dusts and mists 8-hr TWA 1 mg/m3 1 mg/m3 <2%
Inert ingredients (Glass, Sintered Aluminum Oxide, Brass)
------------------------------------------------------------------------------------------------------------
SECTION 3: PHYSICAL CHEMICAL CHARACTERISTICS
This item is a light bulb with a brass base and a refractory alumina inner arc tube.
Chemical/physical data as in a standard MSDS are not applicable
A division of 200 Franklin Square Drive
Philips Electronics North America Corporation P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000
CERAMALUX鈩? HPS with ALTO鈩AMP TECHNOLOGY
1000 WATT Page 2 of 3
SECTION 4: FIRE AND EXPLOSION DATA
Fire and explosion data not applicable to the intact lamp. There is very little sodium in
this lamp. Exposing the broken inner arc tube to water will not produce a fire. Under
extreme heat, outer glass envelope might melt or crack. The inner arc tube is composed
of polycrystalline alumina and is a refractory material.
SECTION 5: REACTVITY DATA
Stability: The lamp is stable
Incompatibility: Glass envelope will react with hydrofluoric acid. Sodium reacts with water, but in this case
the amount of sodium is small enough that the reaction will not be vigorous.
SECTION 6: HEALTH EFFECTS
Not applicable to the intact lamp. The inner envelope is composed of polycrystalline
alumina. Breakage of this envelope may result in some exposure to elemental sodium and
mercury. No adverse effects are expected from occasional exposure to broken lamps. As
a matter of good practice, breakage should be avoided. Prolonged or frequent exposure to
broken envelopes should be avoided through the use of adequate ventilation during
disposal of large quantities of lamps.
SECTION 7: PRECAUTIONS FOR SAFE HANDLING AND USE
Normal precautions should be taken for the collection of broken glass.
Waste Disposal Method: At the end of rated life, when this lamp is removed from
service, it will be subjected to the current Toxic Characteristic Leaching Procedure
(TCLP) prescribed by the Environmental Protection Agency. This test is used to
determining whether an item is a hazardous waste or a non-hazardous waste under
current E. P. A. definition. Philips Lighting will provide the test data on request. This
result will allow the generator to evaluate all of the disposal options, which may be
available in the particular state in which the generator鈥檚 facility is located. The generator
should check with federal, state and local officials for their guidance. In most states
ALTO lamps are considered non-hazardous subtitle D waste. Philips encourages
recycling of its products by qualified recyclers.
.
SECTION 8: CONTROL MEASURES
Respiratory Protection: Appropriate dust mask should be used if large quantities of
lamps are being broken for disposal. NOTE: the Universal Waste Rule issued for mercury
containing lamps issued July 6, 1999 by the E.P.A. specifically discusses the requirement
for a permit if a generator desires to crush lamps on site. Check with your local officials.
Ventilation: Avoid inhalation of any airborne dust. Provide carbon filtration of local
exhaust if it is permitted when disposing of large quantities of lamps.
Hand and Eye protection: Appropriate hand and eye protection should be worn when
disposing of large quantities of lamps or handling broken lamps.
CERAMALUX鈩? HPS with ALTO鈩AMP TECHNOLOGY
1000 WATT Page 3 of 3
SECTION 9: REGULATORY INFORMATION
As a product these mercury containing lamps being shipped in the manufacturer鈥檚
original packaging are not regulated by air, truck or ocean shipment. As a waste, spent
ALTO lamps maybe regulated in various states and local communities. This material
safety data sheet does not constitute 鈥渒nowledge of the waste鈥?, in certain jurisdictions.
TCLP data will be furnished upon request.
.
Prepared: 10/26/99 Revised: 11/06
S19-99001