MATERIAL SAFETY DATA SHEET

PRODUCT: L 1250 - HPM, L 1261 - HPA
(325779, 305581) Revised: 6/01


SECTION 1: MANUFACTURER

Manufacturer's Name and Address: Philips Lighting Company
A Division of Philips Electronics
North America Corporation
200 Franklin Square Drive
Somerset, NJ 08875

Emergency Telephone No.: (800) 424-9300 CHEMTREC
(732) 563-3197 Environmental
Other Information Calls: (800) PLC-BULB

SECTION 2: HAZARDOUS INGREDIENTS

OSHA (PEL) ACGIH (TLV) %

.1mg/m3Ceiling .025mg/m38hr.TWA
Mercury (7439-97-6) <.02
.05mg/m3
Lead Iodide (10101-63-0) * < .1mg/m_ <.02
Gallium Iodide (13450-91-4)* NONE ESTABLISHED <.02
Cobalt (7440-48-4)+ .1 mg/m_ NONE EST'D <.02
Krypton - 85 HPM less than 15 nCi; HPA less than 50 nCi.

*HPM Only. +HPA Only.




A division of 200 Franklin Square Drive
Philips Electronics North America Corporation P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000




L 1250 - HPM, L 1261 - HPA
Page 2 of 5

SECTION 3: CHEMICAL/PHYSICAL DATA

These items are light bulbs. . The bulb is quartz. HPA lamps are about 30 cm long; HPM lamps
are either 24 or 37 cm long. Other chemical or physical characteristics are not applicable.


SECTION 4: FIRE AND EXPLOSION DATA

THE BULB WALL OF THIS ELECTRICAL DISCHARGE LAMP IS COMPOSED OF
QUARTZ AND IS DESIGNED FOR USE ONLY WITH PROPER FIXTURES, IGNITORS
AND BALLASTS. THE LAMP OPERATES UNDER HIGH INTERNAL PRESSURE AT
VERY HIGH TEMPERATURES AS HIGH AS 950鈥? AND MAY RUPTURE
UNEXPECTEDLY. IF RUPTURE OCCURS, DISCHARGE OF EXTREMELY HOT
QUARTZ PARTICLES INTO THE ENCLOSURE AND/OR SURROUNDING
ENVIRONMENT COULD OCCUR, THEREBY CREATING A RISK OF PERSONAL
INJURY, PROPERTY DAMAGE, OR FIRE.


SECTION 5: REACTIVITY DATA

Stability: Envelope is stable.

Incompatibility: Envelope can be affected by oils and fats deposited on surface from fingers.
Handling of envelope should only be done with gloves.

While the amount of lead iodide is small and exposure occurs only if the lamp
is broken the following incompatibility is noted. Lead iodide is incompatible
with hydrogen peroxide, strong oxidizers, sodium and potassium. Fluorine
decomposes lead iodide at ambient temperatures, igniting the liberated iodine
and generating much heat.




A division of 200 Franklin Square Drive
Philips Electronics North America Corporation P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000




L 1250 - HPM, L 1261 - HPA
Page 3 of 5

SECTION 6: HEALTH HAZARD DATA

WARNING: THIS LAMP EMITS SHORTWAVE ULTRAVIOLET RADIATION WHICH IS
HARMFUL TO SKIN AND EYES AND CAN CAUSE SERIOUS SKIN BURNS AND EYE
INFLAMMATION. USE ONLY IN EQUIPMENT SPECIFICALLY DESIGNED TO
REDUCE THE RISK OF PERSONAL INJURY AND PROPERTY DAMAGE RESULTING
FROM ARC TUBE RUPTURE AND FROM ULTRAVIOLET RADIATION. IT IS
RECOMMENDED THAT THIS LAMP BE USED IN FIXTURES HAVING A SAFETY
INTERLOCK SWITCH. LEAD IODIDE IS NOT LISTED AS A CARCINOGEN BY IARC,
NTP, OR OSHA.
------------------------------------------------------------------------------------------------------------------
FIRST AID: If exposure to ultraviolet radiation occurs, it is recommended that an
opthamologist be consulted.


SECTION 7: PRECAUTIONS FOR SAFE HANDLING AND USE

WASTE DISPOSAL METHOD: The lamp contains a small amount of mercury - together with a
small amount of lead iodide. Under the toxicity characteristic leaching procedure (TCLP)
promulgated by the United States E.P.A. tests of used or spent high intensity discharge lamps
indicate that these lamps generally are considered to be hazardous when discarded. (Fed. Reg.
7/27/94.) EPA has issued the Universal waste Rule for lamps which fail the TCLP (Fed Reg
7/6/99). More than thirty States now manage lamps under this Rule. The UWR requires
recycling or hazardous waste disposal of those lamps which fail TCLP. There are some
exemptions which depend on your status, volume and or location. Check with your State
Authorities for information to ensure proper waste disposal practice.




A division of 200 Franklin Square Drive
Philips Electronics North America Corporation P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000




L 1250 - HPM, L 1261 - HPA
Page 4 of 5

SECTION 7: PRECAUTIONS FOR SAFE HANDLING AND USE (Cont'd)
Safe Handling: Read and Follow the installation/operating instructions listed below to help
reduce risk of personal injury and property damage and help prevent early lamp failure:

1) Before lamp installation/replacement, shut power off & allow lamp & fixture to cool to
avoid
electrical shock & potential burn hazards.

2) Protect lamp from abrasions & scratches. Do not install or use cracked or broken lamp. If
lamp cracks or breaks in use, disconnect power supply immediately, allow system to cool &
remove lamp.

3) Do not touch lamp with bare hands. If touched with hands, clean lamp with denatured
alcohol and wipe with a lint-free cloth before installing.

4) Replace lamp at or before the end of rated life. Allowing lamp to operate until it fails is not
recommended and may increase the risk of inner arc tube rupture.

5) Use within voltage limits recommended by ballast manufacturer. Do not operate lamp at
higher than specified power.

6) The permissible maximum operating temperatures (e.g., the pinch temperatures, the
tempera-
ture of the bulb wall) as indicated on the product leaflet may not be exceeded.

7) Lamp should be operated within 10 degrees of the horizontal position to insure maximum
operating efficiency.


SECTION 8: SPECIAL PROTECTION DATA

WARNING: THIS LAMP EMITS SHORTWAVE ULTRAVIOLET RADIATION. USE
ONLY IN EQUIPMENT DESIGNED TO REDUCE RISK OF PERSONAL INJURY AND
PROPERTY DAMAGE. DO NOT LOOK AT OPERATING LAMP WITHOUT
PROTECTIVE FIXTURE AND/OR PROTECTIVE GOGGLES. DO NOT USE LAMP IF
ULTRAVIOLET FILTER GLASS IS MISSING OR DAMAGED.



A division of 200 Franklin Square Drive
Philips Electronics North America Corporation P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000
L 1250 - HPM, L 1261 - HPA
Page 5 of 5

SECTION 9: SPECIAL PRECAUTIONS & COMMENTS

No restrictions as product shipped by truck, air or water. Spent lamps may require D008 RCRA
classification. If state adopts universal waste rule, spent lamps can be shipped using common
carrier and bills-of-lading. Contact your state environmental agency for guidance.




Prepared: 8/9/95 S21-95001




A division of 200 Franklin Square Drive
Philips Electronics North America Corporation P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
nam_lighting_philips_com---s08-93003.asp 7439-92-1 7440-31-5 7440-69-9 7439-97-6
nam_lighting_philips_com---s08-93004.asp 1314-36-9 7439-97-6
nam_lighting_philips_com---s08-97006.asp 1314-36-9 67542-72-7 7439-97-6
nam_lighting_philips_com---s08-98001.asp 1314-36-9 67542-72-7 7440-69-9 7440-74-6 7440-50-8 7439-97-6
nam_lighting_philips_com---s09-01001.asp 7440-36-0 7439-96-5 68585-82-0 68611-47-2 7439-97-6
nam_lighting_philips_com---s09-01002.asp 7440-36-0 7439-96-5 1344-28-1 7439-97-6
nam_lighting_philips_com---s09-01003.asp 7440-36-0 7439-96-5 1314-36-9 1344-28-1 7439-97-6
nam_lighting_philips_com---s09-01004.asp 1314-36-9 7440-36-0 7439-96-5 1306-06-5 7439-97-6
nam_lighting_philips_com---s09-01005.asp 1314-36-9 7440-36-0 7439-96-5 7439-97-6
nam_lighting_philips_com---s09-96002.asp 7440-36-0 7439-96-5 7439-97-6
nam_lighting_philips_com---s09-96003.asp 1314-36-9 1344-28-1 7439-97-6
nam_lighting_philips_com---s09-96004.asp 7440-36-0 7439-96-5 7439-97-6
nam_lighting_philips_com---s09-97001.asp 1314-36-9 7440-36-0 7439-96-5 7439-97-6
nam_lighting_philips_com---s09-98001.asp 1314-36-9 7440-36-0 7439-96-5 1306-06-5 7439-97-6
nam_lighting_philips_com---s09-99001.asp 7757-93-9 1309-64-4 1314-13-2 7439-97-6
nam_lighting_philips_com---s13-93001.asp 7439-97-6
nam_lighting_philips_com---s15-00006.asp 14808-60-7 7439-98-7 7440-33-7 7789-17-5 7789-69-1 7774-29-0 7789-47-1 7439-97-6 1314-23-4
nam_lighting_philips_com---s15-00008.asp 7439-97-6 7681-82-5 7790-30-9 7553-56-2
nam_lighting_philips_com---s15-01001.asp 7439-97-6 7681-82-5 7790-30-9 7553-56-2
nam_lighting_philips_com---s15-05001.asp 7439-97-6 7553-56-2 7790-30-9
nam_lighting_philips_com---s15-05002.asp 7439-97-6 7681-82-5 7790-30-9 10102-68-8
nam_lighting_philips_com---s15-93001.asp 7439-97-6 7553-56-2 7681-82-5 7440-65-5
nam_lighting_philips_com---s15-93002.asp 7439-97-6
nam_lighting_philips_com---s15-93003.asp 7439-97-6
nam_lighting_philips_com---s15-95004.asp 7439-97-6 7681-82-5 7790-30-9 7553-56-2
nam_lighting_philips_com---s15-95005.asp 7439-97-6 7439-92-1 7681-82-5 7790-30-9 7553-56-2
nam_lighting_philips_com---s16-93001.asp 7440-23-5 7439-92-1
nam_lighting_philips_com---s16-93002.asp 7790-30-9 7439-97-6 7439-92-1
nam_lighting_philips_com---s19-97001.asp 7440-23-5 743-97-6 7439-92-1
nam_lighting_philips_com---s19-98001.asp 7440-39-3 7440-23-5 7440-22-4 7439-97-6
nam_lighting_philips_com---s19-99001.asp 7440-39-3 7440-23-5 7440-22-4 7439-97-6 7440-50-8
nam_lighting_philips_com---s21-95001.asp 7439-97-6 10101-63-0 13450-91-4 7440-48-4
nam_lighting_philips_com---s22-98001.asp 1314-36-9 7440-69-9 7440-74-6 7439-97-6 7440-50-8 7440-66-6 7439-92-1 7440-31-5 7439-89-6
nam_lighting_philips_com---s23-00001.asp 7440-33-7 7726-95-6
nam_lighting_philips_com---s23-01001.asp 7726-95-6
nam_lighting_philips_com---s23-99001.asp 7726-95-6 7439-92-1
newparks_com---AdhesiveRemover.asp 75-09-2 8002-74-2 34590-94-8 108-88-3 67-56-1 8052-41-3 12-01-0
newparks_com---BoiledLinseedOil.asp 66071-03-2 27253-31-2 136-52-7 8052-41-3 111-77-3 27253-32-3 15956-58-8 12-01-0
newparks_com---BrushCleaner.asp 108-88-3 78-93-3 64741-41-9 75-09-2 67-56-1 108-65-6 12-01-0
newparks_com---DenaturedAlcohol.asp 64-17-5 67-56-1 108-10-1 141-78-6 64742-89-8 12-01-0
newparks_com---DetailStripper.asp 108-88-3 67-64-1 64741-41-9 75-09-2 67-56-1 12-01-0
newparks_com---FurnitureRefinisher.asp 67-64-1 67-56-1 67-63-0 108-88-3 12-01-0
newparks_com---GumTurpentine.asp 8006-64-2 12-01-0
newparks_com---LacquerThinner.asp 97-85-8 67-64-1 67-56-1 108-88-3 64742-89-8 110-82-7 142-82-5 108-87-2
newparks_com---MagicStrip.asp 1332-58-7 14807-96-6 14808-60-7 872-50-4 1119-40-0 627-93-0 12-01-0
newparks_com---MineralSpirits.asp 8052-41-3 95-63-6 12-01-0
newparks_com---msdsNanoFlS.asp 29911-28-2 112-34-5
newparks_com---msdsNanoGl.asp 112-34-5 102-71-6 29911-28-2
newparks_com---msdsNanoSa.asp 112-34-5 102-71-6 29911-28-2
newparks_com---msdsNanoSg.asp 112-34-5 102-71-6 29911-28-2