庐
Biomolecules for research MATERIAL SAFETY DATA SHEET
Section 1 : Substance Identification
Isoprostane Oxidative Stress Assay Kit A
Name:
AK-150
Catalog Number:
BIOMOL International Inc.
Company Identification:
5120 Butler Pike
Plymouth Meeting PA 19462-1202 USA
(610) 941-0430 (9am-5pm ET)
Section 2 : Chemical Components
Vial # Name: Quantity
80-0060 Goat anti-Rabbit IgG Microtiter Plate 1 plate
80-0108 8-iso-PGF2伪 EIA Conjugate 5 ml
(contains 0.9% sodium azide)
80-0109 8-iso-PGF2伪 EIA Antibody 5 ml
(contains 0.9% sodium azide)
80-0011 Assay Buffer Concentrate 27 ml
(contains 0.9% sodium azide)
80-1286 Wash Buffer Concentrate 27 ml
80-0110 8-iso-PGF2伪 Standard 0.5 ml
80-0075 pNpp Substrate 20 ml
80-0247 Stop Solution 5 ml
(Handle with care, contains 10% Sodium Phosphate, Tribasic / CAS # 10101-89-0)
(contains 0.9% sodium azide)
Section 3 : Health Hazards
The physical, chemical and toxicological properties of many of these components have not yet been fully
investigated. It is therefore advised that all laboratory personnel handling this product follow standard
laboratory safety procedures. It is recommended that personnel wear safety goggles, gloves, and protective
clothing at all times, and avoid direct contact with the reagents supplied in this kit.
Section 4 : First Aid
Eye Contact: Check for and remove contact lenses. Flush eyes with running water for at least 15
minutes separating eyelids. Seek medical attention immediately
Skin Contact: Wash with soap and water for 15 minutes. Remove contaminated clothing and shoes.
If irritation or discomfort develops, seek medical attention.
Inhalation: Remove from exposure. If breathing is difficult, administer oxygen. If breathing stops,
administer artificial respiration. Seek medical attention if patient feels unwell or develops any
respiratory symptoms. Provide chemical label and MSDS if possible.
Ingestion: Remove dentures and clear mouth. If person is conscious, rinse mouth with water. Call
physician or poison control immediately. Provide chemical label and MSDS information if
possible.
Section 5 : Fire / Flammability Information
Flammability: Not Flammable
Flash Point: Not Known
Combustion Products: Carbon monoxide, Carbon dioxide, Nitrogen oxides
Extinguishing Media: Carbon Dioxide, Dry chemical powder, foam
Special Firefighting Procedures: Use self-contained breathing apparatus and protective clothing to
prevent contact with skin and eyes.
Unusual Fire/Explosion Hazards: The flammable components in the acetylation kit can travel
considerable distances as vapor and may experience flashback.
Section 6 : Spill or Leak Procedures.
Cleanup Procedures: Wearing appropriate protective gear as outlined under 鈥淧rotective equipment鈥?
wipe up spill, place in sealed container and hold for appropriate disposal. Wash spill site with soap
and water.
Waste Disposal Method: Dilute waste solutions and reagents with water and dispose of in accordance
with federal, state, and local regulations.
Section 7 : Storage and Handling Precautions
Protective Equipment: For spill clean up, wear suitable protective clothing, chemical resistant rubber
gloves, rubber boots, and chemical safety goggles.
Storage and Handling: The components of this kit should be stored 4掳C. All components should be
kept in tightly closed containers. This product should be handled only by qualified experienced
professionals. Wash thoroughly after handling the materials included in this kit.
Section 8 : Stability and Reactivity Data
Stability: This material is stable until the expiration date on the package if stored as directed
Conditions to Avoid: Protect from exposure to excessive moisture.
Incompatibles: There are no known incompatible reagents for the components of the main kit.
Section 9 : Toxicity
Toxicological Information: None Available
Section 10 : Ecological Data
Ecotoxicological Information: None Available
The above information is believed to be correct but does not purport to be complete and should be used only as a guide. The burden of
safe use of this material rests entirely with the user.
Emergency Contact:
BIOMOL International Inc.
5120 Butler Pike
Plymouth Meeting, PA 19462 USA
(610) 941-0430
Last Revised : 5/21/08
|