Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

84179-66-8

File Name: my_okidata_com---58358601.asp
Material Safety Data Sheet                                        Explosion Data
Like most organic materials in powder form, it can form
MSDS#58358601 explosive mixtures when dispersed in air.
Sensitivity to Mechanical Impact: Not available
Sensitivity to Static Discharge: Not available
Product Identification and Use
Reactivity Data
B6100 Black Toner, P/Ns 52113701 & 52113704

Stability: Stable
For more information, contact Oki Data at 2000 Bishops Gate
Blvd., Mount Laurel, NJ, 08054-4620. Conditions to Avoid: Not available
Emergency Information: Call 1-800-654-3282; US & Canada Polymerization: Not available
Only
Hazardous Decomposition Products: Not available
Incompatibility: Not available
Hazardous Ingredients
Toxicological Properties
Styrene/acrylate copolymer (55-60% by weight)
CAS#: Not available Routes of Entry: Inhalation, Ingestion, Eyes, Skin
Iron oxide (35-40% by weight) Effects of Acute Exposure: Practically non-toxic
CAS#: Not available Swallowed LD50 (rat): >5.0 g/kg1)
Polypropylene (less than 3% by weight) Skin LD50 (rabbit): >2.0 g/kg1)
Inhaled LC50 (rat): >5.0 mg/L/4hr1)
CAS#: Not available
Effects of Chronic Exposure:
Amorphous silica (less than 1% by weight)
The results obtained from a sponsored, Chronic Toner
CAS#: Not available
Inhalation Study, demonstrated no lung change in rats for the
Chromium/azo dye complex (less than 1% by weight)
lowest (1 mg/m3) exposure level (i.e. the level most relevant to
CAS#: 84179-66-8, 10-125-50-0, 109125-51-1 potential human exposure). A very slight degree of fibrosis was
noted in 25% of the animals at the middle (4 mg/m3) exposure
Physical Data level, while a slight degree of fibrosis was noted in all the
animals at the highest (16 mg/m3) exposure level. These
Physical State: Solid
findings are attributed to "lung overloading", a generic response
Melting/Freezing Point: Not available to excessive amounts of any dust retained in the lungs for a
Boiling Point: Not applicable prolonged period. This study was conducted using a special test
PH: Not available. toner to comply with EPA testing protocol. The test toner was
Vapor Pressure: Not applicable ten times more respirable than commercially available OKI
toner, and would not be functionally suitable for OKI
Vapor Density (Air=1): Not available
equipment.1)
Evaporation Rate (Butyl Acetate=1): Not available
Exposure Limits:
Specific Gravity (H2O=1): Not available
ACGIH TLV (2002):
Solubility in water: Negligible
10 mg/m3 (Total)
Solubility in solvents: Not available
3 mg/m3 (Respirable)
Coefficient of water/oil Distribution: Not available
Irritancy: Not an irritant1)
Appearance and odor: Black powder, faint odor
Sensitization: Not a sensitizer1)
Odor Threshold: Not available
Carcinogenicity: Not classified as 鈥淐arcinogens鈥?
Fire and Explosion Hazard Data IARC: No components are listed
NTP: No components are listed
Flammability: Not flammable under conditions of use.
OSHA: No components are listed
Extinguishing Media: In case of fire, use extinguishing media
Reproductive Toxicity: Not classified as 鈥淩eproductive and
(water spray, foam, dry chemicals). When in a machine, treat as
Development chemicals鈥?
an electrical fire.
Teratogenicity: Not available
Flash Point (OC): Not applicable
Mutagenicity: Ames Assay: Negative
Lower Explosive Limit: Not applicable
Name of Toxicologically Synergistic products: Not available
Upper Explosive Limit: Not applicable
Auto-ignition Temperature: Not applicable 1)
This information is based on toxicity data for similar
Hazardous Combustion Products: Not applicable materials and ingredients.
Preventive Measures Emergency First Aid Procedures
Personal Protective Equipment Toner swallowed (ingested).
Respiratory Protection: Not normally required. For large spills, Immediately seek medical attention. Never give anything by
use dust respirator during cleanup. mouth to an unconscious person. If possible, rinse out mouth
and give one or two glasses of water or milk to drink.
Protective Gloves and/or Eye Protection: Not normally
required. For large spills, use rubber gloves and safety goggles Toner inhaled.
during cleanup. Remove person to fresh air. Seek medical attention.
Engineering Controls Toner gets in the eyes.
Ventilation: Outside of normal ventilation, not normally Flush eyes with large quantities of cool water for 15 minutes,
required. keeping the eyelids open with fingers. If necessary, seek
Other Protective Equipment and/or Hygienic Practices: medical attention.
None Toner gets on the skin.
Spill Cleanup Wash toner off the skin with plenty of cool water and soap. If
Small Spills necessary, seek medical attention.
1 Remove sources of ignition.
! Small amounts of toner on skin or clothing can easily be
2 Sweep up or soak up with a damp (cold water) cloth. removed with soap and cold water. Hot water makes toner
harder to remove.
Large Spills
1 Remove sources of ignition.
Preparation Date of MSDS
2 Keep unnecessary and unprotected personnel away from
area. Date: March 1, 2005
3 Wear protective gear: respirator, rubber gloves, goggles. Prepared by:
4 Vacuum the spill, then wipe up remainder with a wet (cold Oki Data Americas, Inc.
water) cloth. Engineering Services Department
5 Place waste material in a closed container. 2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054-4620
Waste Disposal
Tel: (856) 235-2600
鈥? Prevent release of material into natural waters and sewers. FAX: (856) 222-5320
http://www.okidata.com
鈥? Follow appropriate federal, state and local regulations.
my.okidata.com
鈥? DO NOT incinerate toner or a print cartridge.
DO NOT disassemble a print cartridge.
Precautions for Handling or Storage: Protect from the sun.
Store in a cool room, under 104掳F (40掳C).
Special Shipping Information: Non hazardous. Handle
container carefully to avoid shock. Do not drop. Keep dry.




Oki Data Americas, Inc., 2000 Bishops Gate Blvd., Mt. Laurel, NJ 08054-4620
Tel: (856) 235-2600 FAX: (856) 222-5320 http://www.okidata.com my.okidata.com

Oki Data Americas, Inc., 2735 Matheson Blvd. East, Unit 1, Mississauga, Ontario, Canada L4W 4M8
Tel: (800) 654-3282 FAX: (905) 238-4427

Oki Data de Mexico, S.A. de C.V., Mariano Escobedo No. 748 - 8 Piso, Col Anzures, e. p. 11590, Mexico, DF
Tel: +52 55 5263-8780 FAX: +52 55 5263-8785

Oki Data do Brasil, Ltda., Av. Leonardo da Vinci, 1178/1182, Jabaquara, Sao Paulo, Brasil
Tel: 55 11-3444-3500 FAX: 55 11-3444-3501




漏 2005 Oki Data Americas, Inc. 58358601

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
my_okidata_com---58357301.asp N/A
my_okidata_com---58357401_efsp.asp N/A
my_okidata_com---58357601_efsp.asp N/A
my_okidata_com---58358601.asp 84179-66-8
my_okidata_com---58367401_e.asp 1309-38-2 7631-86-9
my_okidata_com---58371301_efsp.asp 1333-86-4
my_okidata_com---58375301.asp N/A
my_okidata_com---58375401.asp N/A
my_okidata_com---58375601_efsp.asp N/A
my_okidata_com---58381801_efsp.asp N/A
my_okidata_com---58381901_efsp.asp N/A
my_okidata_com---58382001_efsp.asp N/A
my_okidata_com---msds_58065301_ribbon_black_for_ml395_395c.asp N/A
my_okidata_com---msds_58065401_ribbon_color_for_ml395_395c.asp 8012-95-1
my_okidata_com---msds_58065501_ribbon_black_film_for_ml395_395c.asp N/A
naturalindustries_com---108.label.msds.asp N/A
naturalindustries_com---ag.msds.asp N/A
naturalindustries_com---dt9.label.msds.asp N/A
naturalindustries_com---seed.label.msds.asp N/A
neogen_com---08820.asp N/A
neogen_com---08838.asp N/A
neogen_com---08839.asp N/A
neogen_com---08866.asp N/A
neogen_com---08874.asp N/A
neogen_com---08879.asp N/A
neogen_com---08880.asp N/A
neogen_com---08883.asp N/A
neogen_com---08884.asp N/A
neogen_com---08888.asp N/A
neogen_com---09055.asp N/A
neogen_com---09062.asp N/A
neogen_com---09063.asp N/A
neogen_com---09064-09066.asp N/A
neogen_com---09067.asp N/A
neogen_com---09068.asp N/A
neogen_com---09070.asp N/A
neogen_com---09071.asp N/A
neogen_com---09072.asp N/A
neogen_com---09073.asp N/A
neogen_com---09074-09076.asp N/A
neogen_com---09080.asp N/A
neogen_com---09081.asp N/A
neogen_com---09085.asp N/A
neogen_com---09090-09093.asp N/A
neogen_com---09094.asp N/A
neogen_com---09095.asp N/A
neogen_com---09100-09115.asp N/A
neogen_com---09116.asp N/A
neogen_com---09117.asp N/A
neogen_com---142674.asp N/A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC