Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

1309-38-2
7631-86-9

File Name: my_okidata_com---58367401_e.asp
Material Safety Data Sheet #58367401
52114501 Print Cartridge Toner
52114502 Print Cartridge Toner

Physical Data __________________
For more information, contact Oki Data at 2000 Bishops
Gate Blvd., Mount Laurel, NJ, 08054-4620.
Physical State: Solid
Emergency Information: call 1-800-654-3282; US & Canada
Melting/Freezing Point: Not available
Only.
Boiling Point: Not applicable
Emergency First Aid ____________ pH: Not available.
Vapor Pressure: Not applicable
Toner swallowed (ingested).
Rinse out mouth with water and give several glasses of water Vapor Density (Air=1): Not available
to drink. Seek medical attention.
Evaporation Rate (Butyl Acetate=1): Not available
Toner inhaled.
Specific Gravity (H2O=1): Not available
Remove person to fresh air. Rinse mouth with water.
Solubility in Water: Negligible
Toner gets in the eyes.
Flush eyes with large quantities of cool water for 15 minutes, Solubility in Solvents: Not available
keeping the eyelids open with fingers. Seek medical Coefficient of Water/Oil Distribution: Not available
attention.
Appearance and Odor: Black powder, faint odor
Toner gets on the skin.
Odor Threshold: Not available
Wash toner off the skin with plenty of cool water and soap.

Fire and Explosion Hazard Data _
Note: Small amounts of toner on skin or clothing can easily
be removed with soap and cold water. Hot water
Flash Point (O掳C): Not applicable.
makes toner harder to remove.
Flammability: Not flammable under conditions of use.
Hazardous Ingredients__________ Flammable Limits
Lower Explosive Limit: Not applicable
Polyester (40-50% by weight)
Upper Explosive Limit: Not applicable
CAS#: Not available
OSHA PEL: Not available. Auto-ignition Temperature: Not applicable
Magnetite (40-50% by weight) Explosion Data
CAS#: 1309-38-2 Like most organic materials in powder form, the toner can
OSHA PEL: Not available. form explosive mixtures when dispersed in air.
Propylene Wax (1-5% by weight) Sensitivity to Mechanical Impact: Not available
CAS#: Not available Sensitivity to Static Discharge: Not available.
OSHA PEL: Not available.
Extinguishing Media: Water spray, foam, dry chemicals.
Ethylene/Propylene Resin (1-5% by weight)
Special Fire Fighting Procedures: In case of fire, use
CAS#: Not available
extinguishing media. When mounted in the printer, treat as an
OSHA PEL: Not available.
electrical fire.
Amorphous Silica (1-5% by weight)
Hazardous Combustion Products: Not applicable
CAS#: 7631-86-9
OSHA PEL: Not available.
Toxicological Properties ________
Routes of Entry: Inhalation, Ingestion, Eyes, Skin
Effects of Acute Exposure (based on toxicity data for similar
materials and ingredients):
Swallowed LD50 (rat): > 5000 mg/kg
Skin LD50 (rabbit): > 5000 mg/kg
Inhaled LC50 (rat): > 5 mg/L/4hr




1
Preventive Measures ___________
Effects of Chronic Exposure (based on toxicity data for
similar materials and ingredients): The results obtained from a
sponsored, Chronic Toner Inhalation Study, demonstrated no Personal Protective Equipment
lung change in rats for the lowest (1 mg/m3) exposure level Respiratory Protection: Not normally required. For large
(i.e. the level most relevant to potential human exposure). spills (such as in bulk processing facilities), use dust
A very slight degree of fibrosis was noted in 25% of the respirator during cleanup.
animals at the middle (4 mg/m3) exposure level, while a slight Protective Gloves and/or Eye Protection: Not normally
degree of fibrosis was noted in all the animals at the highest required. For large spills (such as in bulk processing facili-
(16 mg/m3) exposure level. ties), use rubber gloves and safety goggles during cleanup.
These findings are attributed to "lung overloading," a generic
Engineering Controls
response to excessive amounts of any dust retained in the
Ventilation: Outside of normal ventilation, not normally
lungs for a prolonged period. This study was conducted using
required. In bulk processing facilities, local exhaust
a special test toner to comply with EPA testing protocol. The
ventilation may be required.
test toner was ten times more respirable than commercially
available Oki toner, and would not be functionally suitable Other Protective Equipment and/or Hygienic Practices:
for Oki equipment. None
Exposure Limits, ACGIH TLV鈥?:
Spill Cleanup
鈥? Total: 10 mg/m3
Small Spills
鈥? Respirable: 3 mg/m3
1 Remove sources of ignition.
Irritancy: Not an irritant.鈥?
2 Sweep up or soak up with a damp (cold water) cloth.
Sensitization (skin, guinea pig): Not a sensitizer.鈥?
Large Spills (such as in processing facilities)
Carcinogenicity: Not classified as 鈥淐arcinogens鈥? 鈥?
1 Remove sources of ignition.
IARC: Refer to IARC Monographs on the Evaluation
2 Keep unnecessary and unprotected personnel away from
Carcinogenic Risks to Humans (WHO
area.
International Agency for Research on cancer).
3 Wear protective gear: respirator, rubber gloves, goggles.
NTP: Refer to National Toxicology Program (NTP)
4 After removing the bulk of the spill, wipe up remainder
Report on Carcinogens (NTP).
with a wet (cold water) cloth.
OSHA:Not available.
5 Place waste material in a closed container.
鈥? Based on toxicity data for similar materials and Waste Disposal
ingredients. Follow appropriate federal, state and local regulations.
Precautions
Reproductive Toxicity: Not classified as 鈥淩eproductive and
Precautions for Handling or Storage: Do not incinerate
Development chemicals.鈥?
toner or a print cartridge. Do not disassemble a print
Teratogenicity: Not available. cartridge. Keep in a cool, dry, well-ventilated place. Keep out
of reach of children.
Mutagenicity (Ames Assay): Negative.
Other Precautions: None
Name of Toxicologically Synergistic products: Not
available.
Shipping Information
Reactivity Data _________________ Special Shipping Information: Transport in accordance
with national and local regulations.
Stability: Stable
Preparation Date of MSDS ______
Conditions to Avoid: Not available
Date: April 18,2007
Polymerization: Not available
Hazardous Decomposition or Byproducts: Not available Prepared by:
Incompatibility: Not available Oki Data Americas, Inc.
Engineering Services Department
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054-4620
Tel: (856) 235-2600 FAX: (856) 222-5320
http://www.okidata.com
http://my.okidata.com


2

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
my_okidata_com---58357301.asp N/A
my_okidata_com---58357401_efsp.asp N/A
my_okidata_com---58357601_efsp.asp N/A
my_okidata_com---58358601.asp 84179-66-8
my_okidata_com---58367401_e.asp 1309-38-2 7631-86-9
my_okidata_com---58371301_efsp.asp 1333-86-4
my_okidata_com---58375301.asp N/A
my_okidata_com---58375401.asp N/A
my_okidata_com---58375601_efsp.asp N/A
my_okidata_com---58381801_efsp.asp N/A
my_okidata_com---58381901_efsp.asp N/A
my_okidata_com---58382001_efsp.asp N/A
my_okidata_com---msds_58065301_ribbon_black_for_ml395_395c.asp N/A
my_okidata_com---msds_58065401_ribbon_color_for_ml395_395c.asp 8012-95-1
my_okidata_com---msds_58065501_ribbon_black_film_for_ml395_395c.asp N/A
naturalindustries_com---108.label.msds.asp N/A
naturalindustries_com---ag.msds.asp N/A
naturalindustries_com---dt9.label.msds.asp N/A
naturalindustries_com---seed.label.msds.asp N/A
neogen_com---08820.asp N/A
neogen_com---08838.asp N/A
neogen_com---08839.asp N/A
neogen_com---08866.asp N/A
neogen_com---08874.asp N/A
neogen_com---08879.asp N/A
neogen_com---08880.asp N/A
neogen_com---08883.asp N/A
neogen_com---08884.asp N/A
neogen_com---08888.asp N/A
neogen_com---09055.asp N/A
neogen_com---09062.asp N/A
neogen_com---09063.asp N/A
neogen_com---09064-09066.asp N/A
neogen_com---09067.asp N/A
neogen_com---09068.asp N/A
neogen_com---09070.asp N/A
neogen_com---09071.asp N/A
neogen_com---09072.asp N/A
neogen_com---09073.asp N/A
neogen_com---09074-09076.asp N/A
neogen_com---09080.asp N/A
neogen_com---09081.asp N/A
neogen_com---09085.asp N/A
neogen_com---09090-09093.asp N/A
neogen_com---09094.asp N/A
neogen_com---09095.asp N/A
neogen_com---09100-09115.asp N/A
neogen_com---09116.asp N/A
neogen_com---09117.asp N/A
neogen_com---142674.asp N/A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC