Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: nulon_com_au---msds-ss-stop_smoke.asp
                                      NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 1 of 8



Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION


PRODUCT NAME
NULON STOP SMOKE

SYNONYMS

"Part No. SS500", "viscosity modifier"

PRODUCT USE
Viscosity modifier.

SUPPLIER
Company: Nulon Products Australia Pty Ltd
Address:
17 Yulong Close
Moorebank
NSW, 2170
AUS
Telephone: +61 2 9986 7800
Fax: +61 2 9601 4700



Section 2 - HAZARDS IDENTIFICATION


STATEMENT OF HAZARDOUS NATURE
NON-HAZARDOUS SUBSTANCE. NON-DANGEROUS GOODS. According to the Criteria of
NOHSC, and the ADG Code.

POISONS SCHEDULE
None

RISK SAFETY
None under normal operating conditions. Do not breathe gas/ fumes/ vapour/ spray.
Avoid contact with skin.


Section 3 - COMPOSITION / INFORMATION ON INGREDIENTS

NAME CAS RN %
mineral oil Not avail. >60
NOTE: Manufacturer has supplied full ingredient
information to allow CHEMWATCH assessment.


Section 4 - FIRST AID MEASURES


SWALLOWED
路 Immediately give a glass of water.
路 First aid is not generally required. If in doubt, contact a Poisons Information Centre
or a doctor.



continued...
NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 2 of 8
Section 4 - FIRST AID MEASURES

EYE
If this product comes in contact with eyes:
路 Wash out immediately with water.
路 If irritation continues, seek medical attention.
路 Removal of contact lenses after an eye injury should only be undertaken by skilled
personnel.

SKIN
If skin or hair contact occurs:
路 Flush skin and hair with running water (and soap if available).
路 Seek medical attention in event of irritation.

INHALED
路 If fumes or combustion products are inhaled remove from contaminated area.
路 Other measures are usually unnecessary.

NOTES TO PHYSICIAN
Treat symptomatically.
路 Heavy and persistent skin contamination over many years may lead to dysplastic changes.
Pre-existing skin disorders may be aggravated by exposure to this product.
路 In general, emesis induction is unnecessary with high viscosity, low volatility
products, i.e. most oils and greases.
路 High pressure accidental injection through the skin should be assessed for possible
incision, irrigation and/or debridement.
NOTE: Injuries may not seem serious at first, but within a few hours tissue may become
swollen, discoloured and extremely painful with extensive subcutaneous necrosis. Product
may be forced through considerable distances along tissue planes.


Section 5 - FIRE FIGHTING MEASURES


EXTINGUISHING MEDIA
路 Foam.
路 Dry chemical powder.
路 BCF (where regulations permit).
路 Carbon dioxide.
路 Water spray or fog - Large fires only.

FIRE FIGHTING
路 Alert Fire Brigade and tell them location and nature of hazard.
路 Wear full body protective clothing with breathing apparatus.
路 Prevent, by any means available, spillage from entering drains or water course.
路 Use water delivered as a fine spray to control fire and cool adjacent area.
路 Avoid spraying water onto liquid pools.
路 DO NOT approach containers suspected to be hot.
路 Cool fire exposed containers with water spray from a protected location.
路 If safe to do so, remove containers from path of fire.

FIRE/EXPLOSION HAZARD
路 Combustible.
路 Slight fire hazard when exposed to heat or flame.
路 Heating may cause expansion or decomposition leading to violent rupture of containers.
路 On combustion, may emit toxic fumes of carbon monoxide (CO).
路 May emit acrid smoke.
路 Mists containing combustible materials may be explosive.
Combustion products include: carbon dioxide (CO2), other pyrolysis products typical of
burning organic material.

continued...
NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 3 of 8
Section 5 - FIRE FIGHTING MEASURES

May emit poisonous fumes.

FIRE INCOMPATIBILITY
路 Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine
bleaches, pool chlorine etc. as ignition may result.

HAZCHEM: None


Section 6 - ACCIDENTAL RELEASE MEASURES


EMERGENCY PROCEDURES

MINOR SPILLS
Slippery when spilt.
路 Remove all ignition sources.
路 Clean up all spills immediately.
路 Avoid breathing vapours and contact with skin and eyes.
路 Control personal contact by using protective equipment.
路 Contain and absorb spill with sand, earth, inert material or vermiculite.
路 Wipe up.
路 Place in a suitable labelled container for waste disposal.

MAJOR SPILLS
Slippery when spilt.
Moderate hazard.
路 Clear area of personnel and move upwind.
路 Alert Fire Brigade and tell them location and nature of hazard.
路 Wear breathing apparatus plus protective gloves.
路 Prevent, by any means available, spillage from entering drains or water course.
路 No smoking, naked lights or ignition sources.
路 Increase ventilation.
路 Stop leak if safe to do so.
路 Contain spill with sand, earth or vermiculite.
路 Collect recoverable product into labelled containers for recycling.
路 Absorb remaining product with sand, earth or vermiculite.
路 Collect solid residues and seal in labelled drums for disposal.
路 Wash area and prevent runoff into drains.
路 If contamination of drains or waterways occurs, advise emergency services.

Personal Protective Equipment advice is contained in Section 8 of the MSDS.


Section 7 - HANDLING AND STORAGE


PROCEDURE FOR HANDLING
路 Avoid all personal contact, including inhalation.
路 Wear protective clothing when risk of exposure occurs.
路 Use in a well-ventilated area.
路 Prevent concentration in hollows and sumps.
路 DO NOT enter confined spaces until atmosphere has been checked.
路 DO NOT allow material to contact humans, exposed food or food utensils.
路 Avoid contact with incompatible materials.
路 When handling, DO NOT eat, drink or smoke.
路 Keep containers securely sealed when not in use.
路 Avoid physical damage to containers.

continued...
NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 4 of 8
Section 7 - HANDLING AND STORAGE

路 Always wash hands with soap and water after handling.
路 Work clothes should be laundered separately. Launder contaminated clothing before re-
use.
路 Use good occupational work practice.
路 Observe manufacturer's storing and handling recommendations.
路 Atmosphere should be regularly checked against established exposure standards to ensure
safe working conditions are maintained.

SUITABLE CONTAINER
路 Metal can or drum
路 Packaging as recommended by manufacturer.
路 Check all containers are clearly labelled and free from leaks.

STORAGE INCOMPATIBILITY
CARE: Water in contact with heated material may cause foaming or a steam explosion with
possible severe burns from wide scattering of hot material. Resultant overflow of
containers may result in fire.
路 Avoid reaction with oxidising agents.

STORAGE REQUIREMENTS
路 Store in original containers.
路 Keep containers securely sealed.
路 No smoking, naked lights or ignition sources.
路 Store in a cool, dry, well-ventilated area.
路 Store away from incompatible materials and foodstuff containers.
路 Protect containers against physical damage and check regularly for leaks.
路 Observe manufacturer's storing and handling recommendations.


Section 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION


EXPOSURE CONTROLS



MATERIAL DATA
Not available. Refer to individual constituents.

INGREDIENT DATA
MINERAL OIL:
ES TWA: 5 mg/m3 refined mineral oil mist
Human exposure to oil mist alone has not been demonstrated to cause health effects except
at levels above 5 mg/m3 (this applies to particulates sampled by a method that does not
collect vapour). It is not advisable to apply this standard to oils containing unknown
concentrations and types of additive.

PERSONAL PROTECTION

EYE
路 Safety glasses with side shields
路 Chemical goggles.
路 Contact lenses may pose a special hazard; soft contact lenses may absorb and
concentrate irritants. A written policy document, describing the wearing of lens or
restrictions on use, should be created for each workplace or task. This should include a
review of lens absorption and adsorption for the class of chemicals in use and an account
of injury experience. Medical and first-aid personnel should be trained in their removal
and suitable equipment should be readily available. In the event of chemical exposure,
begin eye irrigation immediately and remove contact lens as soon as practicable. Lens
continued...
NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 5 of 8
Section 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION

should be removed at the first signs of eye redness or irritation - lens should be
removed in a clean environment only after workers have washed hands thoroughly. [CDC
NIOSH Current Intelligence Bulletin 59].

HANDS/FEET
Suitability and durability of glove type is dependent on usage. Factors such as:
路 frequency and duration of contact,
路 chemical resistance of glove material,
路 glove thickness and
路 dexterity,
are important in the selection of gloves.
路 Wear chemical protective gloves, eg. PVC.
路 Wear safety footwear or safety gumboots, eg. Rubber.

OTHER
路 Overalls.
路 P.V.C. apron.
路 Barrier cream.
路 Skin cleansing cream.
路 Eye wash unit.

The local concentration of material, quantity and conditions of use determine the type of
personal protective equipment required.
For further information consult site specific
CHEMWATCH data (if available), or your
Occupational Health and Safety Advisor.

ENGINEERING CONTROLS
General exhaust is adequate under normal operating conditions. If risk of overexposure
exists, wear SAA approved respirator. Correct fit is essential to obtain adequate
protection. Provide adequate ventilation in warehouse or closed storage areas.


Section 9 - PHYSICAL AND CHEMICAL PROPERTIES


APPEARANCE
Light coloured liquid with a mild odour; does not mix with water.

PHYSICAL PROPERTIES
Liquid.
Does not mix with water.
Floats on water.

Molecular Weight: Not applicable Boiling Range (掳 Not av ailable
C):
Melting Range (掳 Not available
C): Specific Gravity (water= 1): 0.87
Solubility in water (g/L): Immiscible pH (as supplied): Not applicable
pH (1% solution): Not applicable Vapour Pressure (kPa): Not available
Volatile Component (%vol): Not available Evaporation Rate: Not available
Relative Vapour Density (air=1): >1 Flash Point (掳 203 (P MCC)
C):
Lower Explosive Limit (%): Not applicable Upper Explosive Limit (%): Not applicable
Autoignition Temp (掳 Not available
C): Decomposition Temp ( 掳 Not available
C):
State: Liquid Viscosity: 5185 cSt@40掳 C




continued...
NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 6 of 8


Section 10 - CHEMICAL STABILITY AND REACTIVITY INFORMATION


CONDITIONS CONTRIBUTING TO INSTABILITY
路 Presence of incompatible materials.
路 Product is considered stable.
路 Hazardous polymerisation will not occur.


Section 11 - TOXICOLOGICAL INFORMATION


POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED
The material has NOT been classified by EC Directives or other classification systems as
"harmful by ingestion". This is because of the lack of corroborating animal or human
evidence. The material may still be damaging to the health of the individual, following
ingestion, especially where pre-existing organ (eg. liver, kidney) damage is evident.
Present definitions of harmful or toxic substances are generally based on doses producing
mortality rather than those producing morbidity (disease, ill-health). Gastrointestinal
tract discomfort may produce nausea and vomiting. In an occupational setting however,
ingestion of insignificant quantities is not thought to be cause for concern.

EYE
Although the liquid is not thought to be an irritant (as classified by EC Directives),
direct contact with the eye may produce transient discomfort characterised by tearing or
conjunctival redness (as with windburn).

SKIN
The liquid may be miscible with fats or oils and may degrease the skin, producing a skin
reaction described as non-allergic contact dermatitis. The material is unlikely to
produce an irritant dermatitis as described in EC Directives .
The material may accentuate any pre-existing dermatitis condition.
Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may
produce systemic injury with harmful effects. Examine the skin prior to the use of the
material and ensure that any external damage is suitably protected.

INHALED
The material is not thought to produce adverse health effects or irritation of the
respiratory tract (as classified by EC Directives using animal models). Nevertheless,
good hygiene practice requires that exposure be kept to a minimum and that suitable
control measures be used in an occupational setting.
Inhalation hazard is increased at higher temperatures.
Not normally a hazard due to non-volatile nature of product.
Inhalation of oil droplets or aerosols may cause discomfort and may produce chemical
inflammation of the lungs.

CHRONIC HEALTH EFFECTS
Substance accumulation, in the human body, may occur and may cause some concern following
repeated or long-term occupational exposure.
Oil may contact the skin or be inhaled. Extended exposure can lead to eczema,
inflammation of hair follicles, pigmentation of the face and warts on the soles of the
feet. Exposure to oil mists can cause asthma, pneumonia and scarring of the lungs. Oils
have been linked to cancer of the skin and scrotum. Compounds that are less viscous and
with smaller molecular weights are more dangerous. There may be liver damage and the
lymph nodes may be affected; heart inflammation can also occur at high doses.
continued...
NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 7 of 8
Section 11 - TOXICOLOGICAL INFORMATION


TOXICITY AND IRRITATION
Not available. Refer to individual constituents.

MINERAL OIL:
unless otherwise specified data extracted from RTECS - Register of Toxic Effects of
Chemical Substances.
Toxicity and Irritation data for petroleum-based mineral oils are related to chemical
components and vary as does the composition and source of the original crude.
A small but definite risk of occupational skin cancer occurs in workers exposed to
persistent skin contamination by oils over a period of years. This risk has been
attributed to the presence of certain polycyclic aromatic hydrocarbons (PAH) (typified by
benz[a]pyrene).
Petroleum oils which are solvent refined/extracted or severely hydrotreated, contain very
low concentrations of both.



Section 12 - ECOLOGICAL INFORMATION

DO NOT discharge into sewer or waterways.
Refer to data for ingredients, which follows:

MINERAL OIL:
DO NOT discharge into sewer or waterways.


Section 13 - DISPOSAL CONSIDERATIONS

路 Recycle wherever possible or consult manufacturer for recycling options.
路 Consult State Land Waste Authority for disposal.
路 Bury or incinerate residue at an approved site.
路 Recycle containers if possible, or dispose of in an authorised landfill.


Section 14 - TRANSPORTATION INFORMATION




HAZCHEM: None


NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS:UN, IATA,
IMDG


Section 15 - REGULATORY INFORMATION


POISONS SCHEDULE: None



continued...
NULON STOP SMOKE
Chemwatch Material Safety Data Sheet
Issue Date: 16-Mar-2008 CHEMWATCH 64519
NC317ECP Version No:4
CD 2008/1 Page 8 of 8
Section 15 - REGULATORY INFORMATION

REGULATIONS
Nulon Stop Smoke (CAS: None):
No regulations applicable

No data available for mineral oil as CAS: Not avail.



Section 16 - OTHER INFORMATION


Classification of the preparation and its individual components has drawn on official and
authoritative sources as well as independent review by the Chemwatch Classification
committee using available literature references.
A list of reference resources used to assist the committee may be found at:
www.chemwatch.net/references.

The (M)SDS is a Hazard Communication tool and should be used to assist in the Risk
Assessment. Many factors determine whether the reported Hazards are Risks in the
workplace or other settings. Risks may be determined by reference to Exposures Scenarios.
Scale of use, frequency of use and current or available engineering controls must be
considered.

This document is copyright. Apart from any fair dealing for the purposes of private study, research, review or
criticism, as permitted under the Copyright Act, no part may be reproduced by any process without written permission
from CHEMWATCH. TEL (+61 3) 9572 4700.

Issue Date: 16-Mar-2008
Print Date: 11-Apr-2008

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
nulon_com_au---msds-e10-worn_engine_treatment.asp N/A
nulon_com_au---msds-e20-performance_engine_treatment.asp N/A
nulon_com_au---msds-e30-long_term_engine_treatment.asp 64742-65-0
nulon_com_au---msds-esl-engine_stop_leak.asp 64742-65-0
nulon_com_au---msds-et4070-40-70_extra_thick_oil.asp 64742-65-0 64742-62-7
nulon_com_au---msds-ezi330-ezi-glide.asp N/A
nulon_com_au---msds-g60-auto_transmission_treatment.asp 64742-65-0
nulon_com_au---msds-g65-power_steering_stop_leak_and_conditioner.asp 64742-65-0
nulon_com_au---msds-g70-manual_gearbox_and_diff_treatment.asp N/A
nulon_com_au---msds-hk20w50-20w-50_high_kilometre_engine_oil.asp 64742-65-0
nulon_com_au---msds-hp-diesel_engine_treatment.asp N/A
nulon_com_au---msds-hp15w40-15w-40_high_protection_diesel_formula_engine_oil.asp 64742-65-0
nulon_com_au---msds-ht10w30-10w-30_hi-tech_fast_flowing_engine_oil.asp 64742-65-0
nulon_com_au---msds-l80-extreme_performance_grease.asp 7620-77-1 9002-84-0
nulon_com_au---msds-l90-extreme_pressure_anti-seize_lubricant.asp 64742-65-0
nulon_com_au---msds-lftu-lifter-free_and_tune-up.asp N/A
nulon_com_au---msds-ll-long_life_concentrated_coolant.asp N/A
nulon_com_au---msds-lltu-long_life_top-up_coolant.asp 107-21-1
nulon_com_au---msds-ls-lead_substitute.asp N/A
nulon_com_au---msds-me15w40-15w-40_modern_everyday_engine_oil.asp 64742-65-0
nulon_com_au---msds-pic-petrol_injector_cleaner.asp N/A
nulon_com_au---msds-pso-pro-strength_octane_booster.asp N/A
nulon_com_au---msds-r50-radiator_stop_leak.asp 107-21-1 7732-18-5
nulon_com_au---msds-rll-red_long_life_concentrated_coolant.asp 107-21-1
nulon_com_au---msds-rlltu-red_long_life_top-up_coolant.asp N/A
nulon_com_au---msds-ss-stop_smoke.asp N/A
nulon_com_au---msds-syb-start_ya_bastard_instant_engine_starter.asp N/A
nulon_com_au---msds-syn15w50-full_synthetic_15w-50_street_and_track_engine_oil.asp 64742-54-7
nulon_com_au---msds-syn5w40-full_synthetic_5w-40_long_life_petrol_and_diesel_engine_oil.asp 64742-54-7
nulon_com_au---msds-synd5w30-full_synthetic_5w-30_long_life_diesel_and_petrol_engine_oil.asp 64742-54-7
nulon_com_au---msds-tfsc-total_fuel_system_cleaner.asp N/A
nulon_com_au---msds-waw-anti-wear_engine_treatment.asp N/A
nulon_com_au---msds-wfs-fuel_system_cleaner.asp N/A
nulon_com_au---msds-wlf-lifter-free_and_tune-up_trade_strength.asp N/A
nulon_com_au---msds-wos-oil_system_cleaner.asp N/A
nulon_com_au---msds-xbf-extreme_performance_brake_fluid.asp N/A
nylexfilmsandfabrics_com_au---msds_aqualux_pool_liner.asp 9000-86-2 117-81-7 9010-88-2 58-36-6
nylexfilmsandfabrics_com_au---msds_boat_hooding.asp 9000-82-2 117-81-7 471-34-7
nylexfilmsandfabrics_com_au---msds_buckskin.asp 9000-82-2 117-81-7 471-34-1
nylexfilmsandfabrics_com_au---msds_capri.asp 9000-82-2 117-81-7 471-34-1
nylexfilmsandfabrics_com_au---msds_cordova.asp 9000-82-2 117-81-7
nylexfilmsandfabrics_com_au---msds_road_runner.asp 9000-82-2 117-81-7
nylexfilmsandfabrics_com_au---msds_tonneau_cover.asp 9000-82-2 117-81-7
nylexfilmsandfabrics_com_au---msds_vacationer_vynaprufe.asp 9000-82-2 117-81-7 471-34-7
ormco_com---acid_etchant.asp 61-00-6 7664-38-2
ormco_com---belleglasshp_metalprep.asp 800-41-0 80-62-6
ormco_com---cavalite_norsk.asp 2004-02-1 56744-60-6 868-77-9 2530-85-0 2867-47-2
ormco_com---cavitecaccelerator.asp 97-53-0
ormco_com---cavitecbase.asp N/A
ormco_com---cleanic_prophy_paste.asp 800-41-0 64-17-5 25-32-3

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC