Search   
MSDS  : TONER FOR M5112, 480-0006
CAS  : 25767-47-9
1333-86-4
9003-07-0
31714-55-3
NAME  : styrene-butyl acrylate copolymer; (styrene acrylate copolyme)
carbon black
polypropylene
2-naphthalenol, 1-.(.(5-chloro-2-hydroxyphenyl)azo.).-, chromium complex;
LANIER WORLDWIDE INC -- TONER FOR M5112, 480-0006
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CJGRM
MSDS NAME: TONER FOR M5112, 480-0006
Responsible Party
Name: LANIER WORLDWIDE INC
Address: 2300 PARKLANE DR NE
City: ATLANTA GA 30345-2979
Info Phone: 404-496-9500
Emergency Phone Number: 800-526-4371
Resp. Party Other MSDS No.: FX-066
Preparer's Name: LANIER QA/EH&S DEPARTMENT
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LANIER WORLDWIDE INC
Address: 2300 PARKLAKE DR NE
City: ATLANTA GA 30345-2979
Phone: 770-723-4208
=======================================================
Item Description Information
=======================================================
=======================================================
Ingredients
=======================================================
Cas: 25767-47-9
Name: STYRENE-BUTYL ACRYLATE COPOLYMER; (STYRENE ACRYLATE COPOLYME)
% low Wt: 86.
% high Wt: 90.
------------------------------
Cas: 1333-86-4
RTECS #: FF5800000
Name: CARBON BLACK
% low Wt: 5.
% high Wt: 6.
OSHA PEL: 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3
ACGIH STEL: NOT ESTABLISHED
------------------------------
Cas: 9003-07-0
RTECS #: UD1842000
Name: POLYPROPYLENE
% low Wt: 4.
% high Wt: 5.
------------------------------
Cas: 31714-55-3
Name: 2-NAPHTHALENOL, 1-.(.(5-CHLORO-2-HYDROXYPHENYL)AZO.).-, CHROMIUM COMPLEX;
(ORGANIC PIGMENT)
Percent by Wt: 2.
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50: (ORAL, RAT) >2.0 G/KG
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: YES
OSHA: NO
Effects of Exposure: MINIMUM IRRIT TO RESP TRACT MAY OCCUR AS W/EXPOS TO ANY
NON-TOXIC DUST. MAY CAUSE GASPING IF INHALED. INHAL SHOULD BE AVOIDED. MAY
CAUSE TEMPORARY EYE DISCOMFORT. CHRONIC: MFR SPONSORED CHRONIC INHAL STUDY
IN RATS USING SPECIAL TEST TONER REVEALED THERE WERE NO LUNG CHGS AT ALL IN
LOWEST EXPOS LEVEL (1MG/M3), MOST RELEVANT LEVEL TO POTNTL HUMAN EXPOSURES. A
VERY SLIGHT DEGREE OF FIBROSIS WAS NOTED IN 25% OF ANIMALS AT MIDDLE EXPOS
LEVEL (4MG/M3), WHILE SLIGHT DEGREE OF FIBROSIS WAS OBSERVED AT HIGHEST EXPOS
LEVEL (16MG/M3) IN ALL ANIMALS. THESE FINDINGS ARE ATTRIBUTED TO "LUNG
OVERLOADING," GE NERIC RESPONSE TO (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: CARBON BLACK: IARC MONOGRAPHS, VOL 65, PG 149,
1996:GROUP 2B.
Signs And Symptions Of Overexposure: HLTH HAZS: EXCESSIVE AMOUNT OF ANY DUST
RETAINED IN THE LUNGS FOR A PRLNGD INTERVAL. SPECIAL TEST TONER WAS TEN TIMES
MORE RESPIRABLE THAN COMMERCIALLY AVAILABLE TONER TO COMPLY W/EPA TESTING
PROTOCOL & WOULD NOT FUNCTION PROPERLY IN XEROGRAPHIC EQUIPMENT.
First Aid: INHALATION: REMOVE TO FRESH AIR IF EFFECTS OCCUR. CONSULT LOCAL
MEDICAL PERSONNEL. EYES: IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES WITH
WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH SOAP AND WATER. INGESTION:
DILUTE STOMACH CONTENTS WITH WATER. CALL MD.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SWEEP UP OR CLEAN UP WITH AN APPROVED TONER VACUUM.
Waste Disposal Methods: WASTE MATERIAL MAY BE DUMPED OR INCINERATED UNDER
CONDITIONS WHICH MEET ALL FEDERAL, STATE AND LOCAL ENVIONMENTAL REGULATIONS.
Handling And Storage Precautions: CLEANSE SKIN AFTER CONTACT BEFORE BREAKS OR
MEALS AND END OF WORK DAY. AVOID INHALATION.
Other Precautions: KEEP OUT OF REACH OF CHILDREN. STORE IN A COOL DRY PLACE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL, FOAM OR WATER. EXTINGUISHING
MEDIA WHICH MAY NOT BE USED FOR SAFETY REASONS: NONE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N).
Unusual Fire/Explosion Hazard: THIS MATERIAL WILL BURN IN CASE OF FIRE. THE
DECOMPOSITION PRODUCTS ARE CARBON MONOXIDE, CARBON DIOXIDE AND NO*X. AVOID
INHALATION OF SMOKE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FP N). NONE REQUIRED UNDER NORMAL USE.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EYE WASH AND DELUGE SHOWER (FP N).
SKIN PROTECTION: NONE REQUIRED UNDER NORMAL USE.
Supplemental Safety and Health: TOXICOLOGICAL INFO: USING TYPICAL TONER
PREPARATION CONTAINING CARBON BLACK DEMONSTRATED NO ASSOCIATION BETWEEN TONER
& TUMOR DEVELOPMENT IN RATS.
=======================================================
Physical/Chemical Properties
=======================================================
Melt/Freeze Pt: =116.C, 240.8F
Spec Gravity: 1.2
Solubility in Water: NEGLIGIBLE
Appearance and Odor: FINE BLACK POWDER; ODORLESS.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE.
Materials To Avoid: NONE.
Hazardous Decomposition Products: CARBON MONOXIDE, CARBON DIOXIDE AND NO*X WHEN
BURNED.
=======================================================
Toxicological Information
=======================================================
Toxicological Information: AMES TEST RSLT: NEGATIVE. SKIN IRRIT (RABBIT): NONE.
EYE IRRIT (RABBIT): MILD. ACUTE INHAL (RAT) 4 HR: LC50 & LCLO ARE IN
EXCESS OF 5.46 G/L. CARCIN: IN 1996, IARC REEVALUATED CARBON BLACK AS GROUP
2B CARCIN (POSS HUMAN CARCIN). THIS EVALUATION IS GIVEN TO CARBON BLACK FOR
WHICH THERE IS INADEQ HUMAN EVID, BUT SUFFICIENT ANIMAL EVID. THE LATTER IS
BASED UPON DEVELOPMENT OF LUNG TUMORS IN RATS RECE IVING CHRONIC INHAL EXPOS
TO FREE CARBON BLACK AT LEVELS THAT INDUCE PARTICLE OVERLOAD OF LUNGS.
STUDIES PERFORMED IN MICE HAVE NOT DEMONSTRATED AN ASSOC BETWEEN CARBON BLACK
& LUNG TUMORS. MOREOVER, TWO-YR CANCER BIOASSAY (SUPDAT)
=======================================================
Ecological Information
=======================================================
Ecological: NONE.
=======================================================
MSDS Transport Information
=======================================================
Transport Information: NONE. THIS IS NOT A HAZARDOUS PRODUCT.
=======================================================
Regulatory Information
=======================================================
Federal Regulatory Information: THEY CONSIST OF CHEMICAL SUBSTANCES WHICH ARE
INCLUDED IN THE TSCA INVENTORY.
=======================================================
Other Information
=======================================================
Other Information: W LEGISLATION (CANADA): THIS PRODUCT IS NOT A CONTROLLED
PRODUCT. HAZARD RATING: HEALTH: 1; FIRE: 1; REACTIVITY: 0; SPECIAL:
NONE.
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: TONER FOR M5112, 480-0006
Company: LANIER WORLDWIDE INC
Street: 2300 PARKLAKE DR NE
City: ATLANTA GA
Zipcode: 30345-2979
Health Emergency Phone: 800-526-4371
Label Required IND: Y
Date Of Label Review: 03/31/1999
Status Code: A
Origination Code: F
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: MINIMUM IRRITATION TO RESPIRATORY TRACT MAY
OCCUR AS WITH EXPOSURE TO ANY NON-TOXIC DUST. MAY CAUSE GASPING IF INHALED.
MAY CAUSE TEMPORARY EYE DISCOMFORT. CHRONIC: CANCER HAZARD. CONTAINS CARB ON
BLACK WHICH IS LISTED AS AN ANIMAL LUNG CARCINOGEN (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
GENERAL PURPOSE POLYSTYRENE, 207 100-42-5
9003-53-6
8042-47-5
GENERAL PURPOSE POLYSTYRENE,208B 100-42-5
9003-53-6
8042-47-5
METALCLAD CERAMALLOY CL+(AC) BLUE BASE
GENERAL PURPOSE POLYSTYRENE, 210 100-42-5
9003-53-6
8042-47-5
METALCLAD CERAMALLOY CL+(AC) ACTIVATOR
GENERAL PURPOSE POLYSTYRENE, C2300 100-42-5
9003-53-6
8042-47-5
N-6605 LSA HAZE GRAY ENAMEL
2033/2033C CATALYST
MC-236 CLASS B BASE
MC-236 ACCELERATOR
Q-HTC FLUID
KONICA DEVELOPER 3240/3340/2230/2330
TONER FOR M5112, 480-0006 25767-47-9
1333-86-4
9003-07-0
31714-55-3
DPD TOTAL CHLORINE REAGNET POWDER PILLOWS
EC MEDIUM/MUG SOLUTION, 22824 9015-54-7
63-42-3
7647-14-5
7732-18-5
E+C GENERAL REPAIR KIT, MA 17100
TONER (MAGENTA)
TONER (CYAN)
METALCLAD CERAMALLOY CL+(AC) ACTIVATOR
TONER (YELLOW)
SILICA REAGENT #3, 4468 6153-56-6
INK CARTRIDGE S020089
CHROMIUM OXIDE
PHILLYCLAD SOLVENT PRT 59 107-98-2
ELECTRONIC SOLV #AR 631-914
POLYSPEC GRIP AC COMPO, 110100 14808-60-7
PSI-901/RC1 ONE-PART 123-86-4
CELVACENE VACUUM GREASE
SPECTRA BLUE GLASS & HARD SURFACE CLEANER 7732-18-5
67-56-1
57018-52-7
MT TONER, EP8603
ECP-PROCESS BLACK, TYPE H, TYPE V80 TONER CONCENTRATE FOR EC
SULFURIC ACID, N/10, 0319 7664-93-9
7732-18-5
SPRAY 'N CLEAN 67-63-0
107-98-2
1589-47-5
7732-18-5
429-GEL
LASERMASTER COLORMARK INKS FOR DESIGN WINDER
WEST SYSTEM 403 MICROFIBERS, 403
TERRAIN, DN4620 65997-15-1
7732-18-5
9003-55-8
DOW CORNING(R) 3-1753 CONFORMAL COATING
SILICA REAGENT #1, 4571 7647-01-0
7732-18-5
DN 4760 GROOVY 8052-41-3
112945-52-5
13463-67-7
14807-96-6
1305-78-8
584-84-9
11024 PROPYLENE GLYCOL USP 57-55-6
ARGON/P-4563-F 7440-37-1
UNITED 477 BEST SHOT 7664-93-9
64742-47-8
95-49-8
TRANSBOND PRIMER 109-16-0
1565-94-2
SILICA REAGENT #2, 4467 12054-85-2
1310-58-3
7732-18-5
MONO-TACK S.E. SPRAY ADHESIVE
TONER (BLACK)
ARMAKLEEN M-AUTO AQUEOUS METAL CLEANER
HS ACRYLIC RAL 5015 P&D BLUE, 91449 1330-20-7
107-87-9
108-10-1
7440-66-6
64742-95-6
107-21-1
CIRCUIT WORKS CONDUCTIVE PEN, CW2200MTP

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net