EPSON AMERICA INC -- INK CARTRIDGE S020089
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CJGSM
MSDS NAME: INK CARTRIDGE S020089
Responsible Party
Name: EPSON AMERICA INC
Address: 20770 MADRONA AVE
City: TORRANCE CA 90503
Info Phone: 800-463-7766;310-782-0770
Emergency Phone Number: 800-463-7766;310-782-0770
Proprietary Ind: Y
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: EPSON AMERICA INC
Address: 20770 MADRONA AVE
City: TORRANCE CA 90503
Phone: 800-463-7766;310-782-0770
=======================================================
Item Description Information
=======================================================
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50 (ORAL, RAT): > 5 G/KG
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: NO HAZARDOUS CLASSIFICATION.
First Aid: INGESTION: NONE REQUIRED. CALL MD IMMEDIATELY (FP N). EYE: FLUSH
THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH SOAP AND
WATER. INHALATION: NONE REQUIRED. REMOVE TO FRESH AIR. SUPPORT BREATHING
(GIVE O*2/ARTF RESP) (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: IF SPILT, USE SPONGE TO WIPE UP THE INK. PLACE IT IN
CLOSED CONTAINER FOR PROPER DISPOSAL.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REGULATIONS.
Handling And Storage Precautions: NONE REQUIRED WHEN USED AS INTENDED IN EPSON
EQUIPMENT.
Other Precautions: NONE REQUIRED WHEN USED AS INTENDED IN EPSON EQUIPMENT. DO
NOT DISMANTLE THE CARTRIDGE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: SCC
Flash Point: >110.C, 230.F
Extinguishing Media: SUITABLE EXTINGUISHING MEDIA. DRY CHEMICAL, CARBON
DIOXIDE.
Fire Fighting Procedures: WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FP N).
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Protective Equipment: EMERGENCY EYEWASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA (FP N).
Supplemental Safety and Health: PH: APPROXIMATELY 9-10 AT ROOM TEMPERATURE.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: NO DATA AVAILABLE
M.P/F.P Text: NO DATA AVAILABLE
Vapor Pres: NO DATA AVAILABLE
Spec Gravity: 1.07 @ 20C
PH: SUPDAT
Viscosity: <5 MPA'S @20C
Appearance and Odor: YELLOW, MAGENTA, AND CYAN LIQUID; NO ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Hazardous Decomposition Products: NONE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: WILL NOT OCCUR.
=======================================================
Toxicological Information
=======================================================
Toxicological Information: BASED ON TOXICOLOGY DATA OF CHEMICALLY SIMILAR
MATERIAL. ACUTE TOXICITY: DERMAL LD 50 AND INHALANT LC 50: NO DATA AVAILABLE.
IRRITATION: SKIN & EYE: NON-IRRITATING (RABBITS). SENSITIZATION:
NON-SENSIT IZING. CARCINOGENICITY: NONE (NOT LISTED IN NTP, IARC MONOGRAPHS,
OSHA REGULATED. MAK LIST AND ANNEX I OF 67/548/EEC). MUTAGENICITY: NONE (BY
AMES TEST).
=======================================================
Ecological Information
=======================================================
Ecological: NO DATA AVAILABLE.
=======================================================
MSDS Transport Information
=======================================================
Transport Information: NO NHAZARDOUS CLASSIFICATION.
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
Other Information: RECOMMENDED USES: INK FOR EPSON INK-JET PRINTERS.
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: INK CARTRIDGE S020089
Company: EPSON AMERICA INC
Street: 20770 MADRONA AVE
City: TORRANCE CA
Zipcode: 90503
Health Emergency Phone: 800-463-7766;310-782-0770
Label Required IND: Y
Date Of Label Review: 03/30/1999
Status Code: A
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: None
Contact Hazard: None
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE/CHRONIC: NO HAZARDOUS CLASSIFICATION.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.