Search   
MSDS  : KONICA DEVELOPER 3240/3340/2230/2330
CAS  :
NAME  : *** proprietary ***
KONICA BUSINESS MACHINES U S A -- KONICA DEVELOPER 3240/3340/2230/2330
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CJGRJ
MSDS NAME: KONICA DEVELOPER 3240/3340/2230/2330
Responsible Party
Name: KONICA BUSINESS MACHINES U S A INC
Address: 500 DAY HILL RD
City: WINDSOR CT 06095
Info Phone: 860-683-2402
Emergency Phone Number: 860-683-2402
Resp. Party Other MSDS No.: 1997803501US, 947-436
Preparer's Name: KONICA CORPORATION
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: SHIN-ETSU CHEMICAL CO LTD
Address: 6-1, 2-CHOME, OHTEMACHI, CHIYODAKU
City: TOKYO, JAPAN NK 00000
Phone: 03-3246-5171
=======================================================
Item Description Information
=======================================================
UI Container Qty: 650G
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50: (ORAL, RAT) >2000 MG/KG
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: YES
OSHA: NO
Effects of Exposure: EYE EFFECTS: NONE CURRENTLY KNOWN. SKIN EFFECTS: NONE
CURRENTLY KNOWN. INGESTION EFFECTS: NONE CURRENTLY KNOWN. INHALATION EFFECTS:
NONE CURRENTLY KNOWN. MINIMAL RESPIRATORY TRACT IRRITATION MAY OCCUR AS WITH
EXPOSURE TO LARGE AMOUNT OF ANY NON-TOXIC DUST. CHRONIC
EFFECTS/CARCINOGENICITY: NO IDENTIFIED HEALTH EFFECTS. CARBON BLACK IS
CLASSIFIED AS GROUP 2B CARCINOGEN (POSSIBLE HUMAN CARCINOGEN) BY IARC.
HOWEVER, BASED ON ANIMAL TESTING, IT IS PRESUMED THAT THERE IS NO ASSOCIATION
BETWEEN TONER EXPOSURE AND CANCER.
Explanation Of Carcinogenicity: CARBON BLACK: IARC MONOGRAPHS, VOL 65, PG 149,
1996:GROUP 2B.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
First Aid: EYES: FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. IF
SYMPTOMS OCCUR, GET MEDICAL ATTENTION. SKIN: WASH WITH WATER AND MILD SOAP.
INGESTION: WASH OUT MOUTH WITH WATER. DRINK ONE OR TWO GLA SSES OF WATER. IF
SYMPTOMS OCCUR, GET MEDICAL ATTENTION. INHALATION: REMOVE VICTIM TO FRESH
AIR. IF SYMPTOMS OCCUR, GET MEDICAL ATTENTION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: WEAR PERSONAL PROTECTIVE EQUIPMENT. MINIMIZE RELEASE
OF PARTICULATES. SWEEP OR VACUUM MATERIAL, PLACE IN BAG AND HOLD FOR WASTE
DISPOSAL. USE VACUUM WITH HEPA FILTER. VACUUM SHOULD BE ELECTRICALLY BON DED
AND GROUNDED TO DISIPATE STATIC ELECTICITY. TO AVOID DUST GENERATION, DO NOT
SWEEP DRY.
Waste Disposal Methods: WHEN DISPOSING OF WASTE OR RECOVERED MATERIAL, CONSULT
FEDERAL, STATE AND LOCAL REGULATIONS FOR THE PROPER DISPOSAL METHOD.
Handling And Storage Precautions: KEEP OUT OF REACH OF CHILDREN. AVOID CONTACT
WITH EYES. KEEP AWAY FROM HEAT, SPARKS AND FLAME. KEEP CONTAINER TIGHTLY
CLOSED. STORE IN A COOL AND DRY PLACE. KEEP AWAY FROM OXIDIZERS.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: WATER SPRAY, DRY CHEMICAL, FOAM.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N). IF FIRE IS IN THE MACHINE TREAT AS AN ELECTRIC FIRE; DO NOT USE WATER
OR FOAM.
Unusual Fire/Explosion Hazard: WILL BURN IF INVOLVED IN A FIRE. HAZARDOUS
COBUSTION PRODUCTS: CARBON MONOXIDE, CARBON DIOXIDE AND SMOKE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NOT REQUIRED UNDER NORMAL CONDITIONS. FOR USE OTHER
THAN IN NORMAL OPERATING PROCEDURES (SUCH AS IN THE EVENT OF LARGE SPILL),
ANSI APPROVED GOGGLES AND NIOSH APPROVED RESPIRATORS MAY BE REQUIRED.
Ventilation: NOT REQUIRED UNDER NORMAL CONDITIONS.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Protective Equipment: EMERGENCY EYE WASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA (FP N).
Supplemental Safety and Health: TOXICOLOGICAL INFO: GENERIC RESPONSES TO
PRESENCE OF LG QTYS OF RESPIRABLE, INSOL & RELATIVELY BENIGN DUSTS
RETAINED FOR EXTENDED TIME PERIODS IN LUNGS. LUNG TUMOR FREQUENCY UNCHANGED
AMONG RATS EXPOS TO TONER AT 3 TIMES EXPOS LEVELS & FOR AIR-ONLY CTL
RATS. MUTAGENICITY - AMES TEST:NEG. CARBON BLACK - (OTHER INFO)
=======================================================
Physical/Chemical Properties
=======================================================
Melt/Freeze Pt: =130.C, 266.F
M.P/F.P Text: SOFTENING PT-TONER
Spec Gravity: 5.0
Solubility in Water: INSOLUBLE
Appearance and Odor: GRAY AND GRANULAR (MEAN DIA IS ABOUT 60UM BY VOLUME).
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: STABLE EXCEPT ABOVE 200C.
Materials To Avoid: OXIDIZERS.
Hazardous Decomposition Products: CARBON MONOXIDE, CARBON DIOXIDE AND SMOKE.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
Toxicological Information: PROD: ACUTE DERMAL TOX: LD50:>2000MG/KG (RAT).
EYE/SKIN IRRIT: NON-IRRITANT (RABBIT). SKIN SENSIT: NON-SENSITIZING (GPG).
CHRONIC EFTS/CARCIN: IN 2-YR INHAL STUDY OF CHRONIC TOX & CARCIN USING
TYPICAL TONER IN RATS, THERE WERE NO LUNG CHGS AT ALL IN LOWEST EXPOS LEVEL
(1MG/M3), MOST RELEVANT LEVEL TO POTNTL HUMAN EXPOS. MINIMAL TO MILD DEGREE
OF FIBROSIS NOTED IN 22% OF ANIMALS AT MID EXPOS LEVEL (4MG/M3) & MILD
TO MOD DEGREE OF FIBROSIS OBSERVED IN 92% OF RATS AT HIGHEST EXPOS LEVEL
(16MG/M3). LUNG CHGS OBSERVED IN HIGHER EXPOS GROUPS ARE INTERPRETED IN TERMS
OF "LUNG OVERLOADING," A SERIES O F (SUPDAT)
=======================================================
Ecological Information
=======================================================
Ecological: NO DATA AVAILABLE. OTHER INFO: CARBON BLACK & LUNG TUMORS.
MOREOVER, TWO-YEAR CANCER BIOASSAY USING TYPICAL TONER PREPARATION CONTAINING
CARBON BLACK DEMONSTRATED NO ASSOC BETWEEN TONER EXPOS & TUMOR
DEVELOPMENT IN RATS. (SEE CHRONIC EFTS.)
=======================================================
MSDS Transport Information
=======================================================
Transport Information: DOT/TDG CLASS: NOT REGULATED. UN CLASS: NOT REGULATED.
=======================================================
Regulatory Information
=======================================================
Sara Title III Information: SARA TITLE III (SUPERFUND AMENDMENTS AND
REAUTHORIZATION ACT) - 302 EXTREME HAZARDOUS SUBSTANCE: NONE. 311/312 HAZARD
CATEGORIES: NONE. 313 REPORTABLE INGREDIENTS: NONE.
Federal Regulatory Information: OSHA HAZARD COMMUNICATION STANDARD, 29 CFR
1910.1200: INGREDIENT CARBON BLACK IS CONSIDERED HAZARDOUS. CERCLA
(COMPREHENSIVE ENVIRONMENTAL RESPONSE COMPENSATION AND LIABILITY ACT): NONE.
TSCA (TOXIC S UBSTANCE CONTROL ACT): ALL CHEMICAL SUBSTANCES IN THIS PRODUCT
COMPLY WITH ALL APPLICABLE RULES OR ORDER UNDER TSCA.
State Regulatory Information: THIS PRODUCT CONTAINS NO CHEMICAL SUBSTANCES
SUBJECT TO CALIFORNIA PROPOSITION 65.
=======================================================
Other Information
=======================================================
Other Information: HAZARD RATING HEALTH: 1; FLAMMABILITY: 1; REACTIVITY: 0.
SUPDAT: CARCIN: IARC REEVALUATED CARBON BLACK AS GROUP 2B CARCIN (POSS HUMAN
CARCIN) IN MONO VOL 65 IN 1996. THIS CATEGORY HAS BEEN GIVEN TO CARBON
BLACK, BASED ON IARC'S EVALUATIONS THAT THERE IS INADEQ EVID IN HUMANS FOR
CARCIN OF CARBON BLACK, BUT THERE IS SUFFICIENT EVID IN EXPERIMENTAL ANIMALS.
LATTER EVALUATION WAS MADE DUE TO DEV ELOPMENT OF LUNG TUMORS IN RATS
RECEIVING CHRONIC INHAL EXPOS TO FREE CARBON BLACK AT LEVELS THAT INDUCE
"LUNG OVERLOADING." HOWEVER, STUDIES PERFORMED IN MICE HAVE NOT DEMONSTRATED
AN ASSOC BETWEEN ( ECOLOGICAL INFO)
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: KONICA DEVELOPER 3240/3340/2230/2330
Company: SHIN-ETSU CHEMICAL CO LTD
Street: 6-1, 2-CHOME, OHTEMACHI, CHIYODAKU
City: TOKYO, JAPAN NK
Zipcode: 00000
Health Emergency Phone: 860-683-2402
Label Required IND: Y
Date Of Label Review: 03/31/1999
Status Code: A
Origination Code: F
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: MINIMAL RESPIRATORY TRACT IRRITATION MAY OCCUR
AS WITH EXPOSURE TO LARGE AMOUNT OF ANY NON-TOXIC DUST. CHRONIC: CANCER
HAZARD. CONTAINS MATERIAL WHICH IS LISTED AS AN ANIMAL LUNG CARCINOGEN (FP
N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
GENERAL PURPOSE POLYSTYRENE, 207 100-42-5
9003-53-6
8042-47-5
GENERAL PURPOSE POLYSTYRENE,208B 100-42-5
9003-53-6
8042-47-5
METALCLAD CERAMALLOY CL+(AC) BLUE BASE
GENERAL PURPOSE POLYSTYRENE, 210 100-42-5
9003-53-6
8042-47-5
METALCLAD CERAMALLOY CL+(AC) ACTIVATOR
GENERAL PURPOSE POLYSTYRENE, C2300 100-42-5
9003-53-6
8042-47-5
N-6605 LSA HAZE GRAY ENAMEL
2033/2033C CATALYST
MC-236 CLASS B BASE
MC-236 ACCELERATOR
Q-HTC FLUID
KONICA DEVELOPER 3240/3340/2230/2330
TONER FOR M5112, 480-0006 25767-47-9
1333-86-4
9003-07-0
31714-55-3
DPD TOTAL CHLORINE REAGNET POWDER PILLOWS
EC MEDIUM/MUG SOLUTION, 22824 9015-54-7
63-42-3
7647-14-5
7732-18-5
E+C GENERAL REPAIR KIT, MA 17100
TONER (MAGENTA)
TONER (CYAN)
METALCLAD CERAMALLOY CL+(AC) ACTIVATOR
TONER (YELLOW)
SILICA REAGENT #3, 4468 6153-56-6
INK CARTRIDGE S020089
CHROMIUM OXIDE
PHILLYCLAD SOLVENT PRT 59 107-98-2
ELECTRONIC SOLV #AR 631-914
POLYSPEC GRIP AC COMPO, 110100 14808-60-7
PSI-901/RC1 ONE-PART 123-86-4
CELVACENE VACUUM GREASE
SPECTRA BLUE GLASS & HARD SURFACE CLEANER 7732-18-5
67-56-1
57018-52-7
MT TONER, EP8603
ECP-PROCESS BLACK, TYPE H, TYPE V80 TONER CONCENTRATE FOR EC
SULFURIC ACID, N/10, 0319 7664-93-9
7732-18-5
SPRAY 'N CLEAN 67-63-0
107-98-2
1589-47-5
7732-18-5
429-GEL
LASERMASTER COLORMARK INKS FOR DESIGN WINDER
WEST SYSTEM 403 MICROFIBERS, 403
TERRAIN, DN4620 65997-15-1
7732-18-5
9003-55-8
DOW CORNING(R) 3-1753 CONFORMAL COATING
SILICA REAGENT #1, 4571 7647-01-0
7732-18-5
DN 4760 GROOVY 8052-41-3
112945-52-5
13463-67-7
14807-96-6
1305-78-8
584-84-9
11024 PROPYLENE GLYCOL USP 57-55-6
ARGON/P-4563-F 7440-37-1
UNITED 477 BEST SHOT 7664-93-9
64742-47-8
95-49-8
TRANSBOND PRIMER 109-16-0
1565-94-2
SILICA REAGENT #2, 4467 12054-85-2
1310-58-3
7732-18-5
MONO-TACK S.E. SPRAY ADHESIVE
TONER (BLACK)
ARMAKLEEN M-AUTO AQUEOUS METAL CLEANER
HS ACRYLIC RAL 5015 P&D BLUE, 91449 1330-20-7
107-87-9
108-10-1
7440-66-6
64742-95-6
107-21-1
CIRCUIT WORKS CONDUCTIVE PEN, CW2200MTP

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net