Search   
MSDS  : ARGON/P-4563-F
CAS  : 7440-37-1
NAME  : argon
PRAXAIR INC -- ARGON/P-4563-F
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CJGXV
MSDS NAME: ARGON/P-4563-F
Responsible Party
Name: PRAXAIR INC
Address: 39 OLD RIDGEBURY RD
Box: 2153
City: DANBURY CT 06817-0001
Info Phone: 203-794-5783
Emergency Phone Number: 800-772-9247
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: PRAXAIR, INC.
Address: 39 OLD RIDGEBURY RD
City: DANBURY CT 06810-5113
Phone: 800-772-9247; 800-PRAXAIR
=======================================================
Ingredients
=======================================================
Cas: 7440-37-1
RTECS #: CF2300000
Name: ARGON
> Wt: 99.
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: NO
Effects of Exposure: INHALATION: ASPHYXIANT. EFFECTS ARE DUE TO LACK OF OXYGEN
WHICH CAN KILL. SKIN/EYES: NO HARM EXPECTED.
Signs And Symptions Of Overexposure: ASPHYXIATION, HEADACHE, DROWSINESS,
DIZZINESS, EXCITATION, EXCESS SALIVATION, VOMITING, UNCONSCIOUSNESS
First Aid: INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE CPR/OXYGEN
IF NECESSARY GIVEN BY QUALIFIED PERSONNEL. SKIN: FLUSH W/WATER. EYES: FLUSH
W/WARM WATER. HOLD EYELIDS OPEN & AWAY FROM THE EYEBALLS TO ENSURE THAT
ALL SURFACES ARE FLUSHED THOROUGHLY. OBTAIN MEDICAL ATTENTION IN ALL CASES.
NOTES TO PHYSICIAN: THERE IS NO SPECIFIC ANTIDOTE. THIS PRODUCT IS INERT.
TREATMENT OF OVEREXPOSURE SHOULD BE DIRECTED AT THE CONTROL OF SYMPTOMS
& THE CLINICAL CONDITION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CAUTION! HIGH PRESSURE GAS. EVACUATE ALL PERSONNEL
FROM AREA. USE SCBA WHERE NEEDED. SHUT OFF FLOW IF W/O RISK. VENTILATE
AREA/MOVE CYLINDER TO A WELL-VENTILATED AREA. TEST FOR SUFFICIENT OXYGEN,
ESPE CIALLY IN CONFINED SPACES, BEFORE ALLOWING REENTRY. PREVENT WASTE FROM
CONTAMINATING THE SURROUNDING ENVIRONMENT. KEEP PERSONNEL AWAY.
Waste Disposal Methods: DISCARD ANY PRODUCT, RESIDUE, DISPOSABLE
CONTAINER/LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE
W/FEDERAL, STATE & LOCAL REGULATIONS.
Handling And Storage Precautions: STORE & USE W/ADEQUATE VENTILATION.
SECURE CYLINDERS UPRIGHT TO KEEP FROM FALLING/BEING KNOCKED OVER. STORE ONLY
WHERE TEMP WILL NOT EXCEED 125F. STORE FULL/EMPTY CONTAINERS SEPARATELY. USE
FIRST IN, FIRST OUT INVENTORY SYSTEM. PROTECT CYLINDERS FROM DAMAGE.
Other Precautions: USE A SUITABLE HAND TRUCK TO MOVE CYLINDERS; DON'T
DRAG/ROLL/SLIDE/DROP. SCREW VALVE PROTECTION CAP IN PLACE BY HAND. NEVER
ATTEMPT TO LIFT A CYLINDER BY ITS CAP; NEVER INSERT AN OBJECT INTO CAP OPENI
NGS. NEVER APPLY FLAME/LOCALIZED HEAT DIRECTLY TO CYLINDER. NEVER STRIKE AN
ARC ON A COMPRESSED GAS CYLINDER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: USE MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures: EVACUATE PERSONNEL. IMMEDIATELY DELUGE CYLINDERS
W/WATER FROM A DISTANCE UNTIL COOL, MOVE THEM AWAY FROM FIRE AREA W/O RISK.
SELF CONTAINED BREATHING APPARATUS MAY BE REQUIRED BY RESCUE WORKERS. ON SI
TE FIRE BRIGADES MUST COMPLY W/OSHA 29 CFR 1910.156.
Unusual Fire/Explosion Hazard: HEAT OF FIRE CAN BUILD PRESSURE IN CYLINDER
& CAUSE IT TO RUPTURE. NO PART OF CYLINDER SHOULD BE SUBJECTED TO A
TEMPERATURE HIGHER THAN 125F. ARGON CYLINDERS ARE EQUIPPED W/A PRESSURE
RELIEF DEVICE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE AIR-PURIFYING/AIR SUPPLIED RESPIRATORS WHERE
LOCAL/GENERAL EXHAUST IS INADEQUATE. AN AIR SUPPLIED RESPIRATOR MUST BE USED
IN CONFINED SPACES. RESPIRATORY PROTECTION MUST CONFORM TO OSHA RULES AS
SPECIFIED IN 29 CFR 1910.134.
Ventilation: LOCAL EXHAUST: TO PREVENT OXYGEN DEFICIENCY & KEEP FUMES &
GASES BELOW TLVS IN WORKER'S BREATHING ZONE. MECHANICAL GENERAL: TO MAINTAIN
AIR SUPPLY.
Protective Gloves: WORK GLOVES WHEN HANDLING; WELDING GLOVES FOR WELDING.
Eye Protection: SAFETY GLASSES WHEN HANDLING. FOR WELDING: HELMET/FACESHIELD
W/FILTER LENS.
Other Protective Equipment: METATARSAL SHOES FOR CYLINDER HANDLING. FOR
WELDING: HAND/HEAD/BODY PROTECTION ANSI Z49.1, ARM PROTECTORS, APRONS, HATS,
SHOULDER PROTECTION, DARK SUBSTANTIAL CLOTHING.
Work Hygienic Practices: DON'T USE ELECTRIC ARCS IN THE PRESENCE OF CHLORINATED
HYDROCARBON VAPORS-HIGHLY TOXIC PHOSGENE MAY BE PRODUCED. USING ARGON IN
WELDING & CUTTING MAY CREATE ADDITIONAL HAZARDS.
Supplemental Safety and Health: KEEP YOUR HEAD OUT OF FUMES. DON'T BREATHE
FUMES & GASES. USE ENOUGH VENTILATION, LOCAL EXHAUST/BOTH TO KEEP FUMES
& GASES FROM YOUR BREATHING ZONE & THE GENERAL AREA.
=======================================================
Physical/Chemical Properties
=======================================================
Boiling Point: =-185.8C, -302.6F
Melt/Freeze Pt: =-189.1C, -308.6F
Solubility in Water: 0.056%/WT
Appearance and Odor: COLORLESS, ODORLESS, TASTELESS GAS AT NORMAL TEMPERTURE &
PRESSURE.
Percent Volatiles by Volume: 100
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Hazardous Decomposition Products: OZONE, NITROGEN OXIDES MAY BE FORMED BY
RADIATION FROM ARC.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
Toxicological Information: ARGON IS A SIMPLE ASPHYXIANT.
=======================================================
Ecological Information
=======================================================
Ecological: NO ADVERSE ECOLOGICAL EFFECTS EXPECTED. ARGON DOES NOT CONTAIN ANY
CLASS I /CLASS II OZINE-DEPLETING CHEMICALS. ARGON IS NOT LISTED AS A MARINE
POLLUTANT BY DOT.
=======================================================
MSDS Transport Information
=======================================================
Transport Information: DOT/IMO SHIPPING NAME: ARGON, COMPRESSED. IDENTIFICATION
NUMBER: UN1006. SHIPPING LABEL: NONFLAMMABLE GAS. CYLINDERS SHOULD BE
TRANSPORTED IN A SECURE POSITION, IN A WELL VENTILATED VEHICLE. CYLINDERS
TRANSPORTED IN AN ENCLOSED, NONVENTILATED COMPARTMENT OF A VEHICLE CAN
PRESENT SERIOUS SAFETY HAZARDS.
=======================================================
Regulatory Information
=======================================================
Sara Title III Information: SECTIONS 302/302: REQUIRE EMERGENCY PLANNING BASED
ON THRESHOLD PLANNING QUANTITY & RELEASE REPORTING BASED ON REPORTABLE
QUANTITIES OF EXTREMELY HAZARDOUS SUBSTANCES. SECTIONS 311/312: REQUIRE
SUBMIS SION OF MATERIAL SAFETY DATA SHEETS & CHEMICAL INVENTORY REPORTING
W/IDENTIFICATION OF EPA HAZARD CATEGORIES: PRESSURE.
State Regulatory Information: PENNSYLVANIA: THIS PRODUCT IS SUBJECT TO THE
PENNSYLVANIA WORKER & COMMUNITY RIGHT-TO-KNOW ACT 35 P.S. SECTIONS
73001-7320.
=======================================================
Other Information
=======================================================
Other Information: AVOID ARC OPERATIONS ON PARTS W/PHOSPHATE RESIDUES;
ANTI-RUST, CLEANING PREPARATIONS-HIGH TOXIC PHOSPHINE MAY BE PRODUCED.
PRAXAIR ASK USERS OF THIS PRODUCT TO STUDY MSDS & BECOME AWARE OF PRODUCT
HAZ ARDS & SAFETY INFORMATION. 1)TO PROMOTE SAFE USE OF THIS PRODUCT, A
USER SHOULD NOTIFY EMPLOYEES/AGENTS/CONTRACTORS OF THE INFORMATION ON THIS
MSDS & OF ANY OTHER KNOWN PRODUCT HAZARDS & SAFETY INFORM ATION.
2)FURNISH THIS INFORMATION TO EACH PURCHASER OF THE PRODUCT. 3) ASK EACH
PURCHASER TO NOTIFY ITS EMPLOYEES & CUSTOMERS OF THE PRODUCT HAZARDS
& SAFETY INFORMATION.
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: ARGON/P-4563-F
Company: PRAXAIR, INC.
Street: 39 OLD RIDGEBURY RD
City: DANBURY CT
Zipcode: 06810-5113
Health Emergency Phone: 800-772-9247
Label Required IND: Y
Date Of Label Review: 06/29/1999
Status Code: A
Origination Code: G
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
GENERAL PURPOSE POLYSTYRENE, 207 100-42-5
9003-53-6
8042-47-5
GENERAL PURPOSE POLYSTYRENE,208B 100-42-5
9003-53-6
8042-47-5
METALCLAD CERAMALLOY CL+(AC) BLUE BASE
GENERAL PURPOSE POLYSTYRENE, 210 100-42-5
9003-53-6
8042-47-5
METALCLAD CERAMALLOY CL+(AC) ACTIVATOR
GENERAL PURPOSE POLYSTYRENE, C2300 100-42-5
9003-53-6
8042-47-5
N-6605 LSA HAZE GRAY ENAMEL
2033/2033C CATALYST
MC-236 CLASS B BASE
MC-236 ACCELERATOR
Q-HTC FLUID
KONICA DEVELOPER 3240/3340/2230/2330
TONER FOR M5112, 480-0006 25767-47-9
1333-86-4
9003-07-0
31714-55-3
DPD TOTAL CHLORINE REAGNET POWDER PILLOWS
EC MEDIUM/MUG SOLUTION, 22824 9015-54-7
63-42-3
7647-14-5
7732-18-5
E+C GENERAL REPAIR KIT, MA 17100
TONER (MAGENTA)
TONER (CYAN)
METALCLAD CERAMALLOY CL+(AC) ACTIVATOR
TONER (YELLOW)
SILICA REAGENT #3, 4468 6153-56-6
INK CARTRIDGE S020089
CHROMIUM OXIDE
PHILLYCLAD SOLVENT PRT 59 107-98-2
ELECTRONIC SOLV #AR 631-914
POLYSPEC GRIP AC COMPO, 110100 14808-60-7
PSI-901/RC1 ONE-PART 123-86-4
CELVACENE VACUUM GREASE
SPECTRA BLUE GLASS & HARD SURFACE CLEANER 7732-18-5
67-56-1
57018-52-7
MT TONER, EP8603
ECP-PROCESS BLACK, TYPE H, TYPE V80 TONER CONCENTRATE FOR EC
SULFURIC ACID, N/10, 0319 7664-93-9
7732-18-5
SPRAY 'N CLEAN 67-63-0
107-98-2
1589-47-5
7732-18-5
429-GEL
LASERMASTER COLORMARK INKS FOR DESIGN WINDER
WEST SYSTEM 403 MICROFIBERS, 403
TERRAIN, DN4620 65997-15-1
7732-18-5
9003-55-8
DOW CORNING(R) 3-1753 CONFORMAL COATING
SILICA REAGENT #1, 4571 7647-01-0
7732-18-5
DN 4760 GROOVY 8052-41-3
112945-52-5
13463-67-7
14807-96-6
1305-78-8
584-84-9
11024 PROPYLENE GLYCOL USP 57-55-6
ARGON/P-4563-F 7440-37-1
UNITED 477 BEST SHOT 7664-93-9
64742-47-8
95-49-8
TRANSBOND PRIMER 109-16-0
1565-94-2
SILICA REAGENT #2, 4467 12054-85-2
1310-58-3
7732-18-5
MONO-TACK S.E. SPRAY ADHESIVE
TONER (BLACK)
ARMAKLEEN M-AUTO AQUEOUS METAL CLEANER
HS ACRYLIC RAL 5015 P&D BLUE, 91449 1330-20-7
107-87-9
108-10-1
7440-66-6
64742-95-6
107-21-1
CIRCUIT WORKS CONDUCTIVE PEN, CW2200MTP

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net