Search   
MSDS  
:
 SILVER ALLOY 25, 25L, 30, 35, 45, 50, 50N
CAS  
:
 7440-22-4
7440-43-9
7440-50-8
NAME  
:
 silver
zinc (as oxide) mf cas# 7723-66-6
cadmium
copper
nickel (in 50n only) mf cas# 7440-02-0
=====================  Product Identification  =====================

MSDS NAME:SILVER ALLOY 25, 25L, 30, 35, 45, 50, 50N
NIIN:00-528-3882
Status Code:A
MSDS Number: CLPVZ
=== Responsible Party ===
Company:AUFHAUSER CORP
Address:39 WEST MALL
City:PLAINVIEW
State:NY
ZIP:11803-4209
Country:US
Info Phone Num:212-757-6824/FAX: 516-694-8690
Emergency Phone Num:516-694-8696 (9-5)
CAGE:59401
=== Contractor Identification ===
Company:AUFHAUSER CORP
Address:39 WEST MALL
Box:City:PLAINVIEW
State:NY
ZIP:11803-4209
Country:US
Phone:212-757-6824/FAX: 516-694-8690
Contract Num:SP0490-02-M-Y183
CAGE:59401

=============  Composition/Information on Ingredients  =============

Name:SILVER
CAS:7440-22-4
RTECS #:VW3500000
Minumum % Wt:20.
Maxumum % Wt:50.
OSHA PEL:0.01 MG/M3
ACGIH TLV:0.1 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:ZINC (AS OXIDE) MF CAS# 7723-66-6
Minumum % Wt:16.
Maxumum % Wt:30.

Name:CADMIUM
CAS:7440-43-9
RTECS #:EU9800000
Minumum % Wt:5.
Maxumum % Wt:24.
OSHA PEL:SEE 1910.1027
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Name:COPPER
CAS:7440-50-8
RTECS #:GL5325000
Minumum % Wt:15.
Maxumum % Wt:45.
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:NICKEL (IN 50N ONLY) MF CAS# 7440-02-0
Minumum % Wt:0.
Maxumum % Wt:3.

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:EYE-MAY CAUSE IRRITATION. SKIN-MAY
    CAUSE IRRITATION.INHALATION-MAY CAUSE EXCESSIVE CADMIUM ABSORPTION
    RESULTING IN PULMONARY EMPHYSEMA &/OR KIDNEY DYSFUNCTION. INGESTION
    IS HARMFUL. COPPER POISONING C AN RESULT IN HEMOLYTIC ANEMIA &
    KIDNEY, LIVER & SPLEEN DAMAGE. NOTE: INHALTION OF FUMES MAY CAUSE A
    FLU-LIKE ILLNESS CALLED METAL FUME FEVER. TYPICALLY METAL FUME
    FEVER BEGINS 4-12 HRS AFTER SUFFICIEN T EXPOSURE TO FRESHLY FORMED
    FUMES. CHRONIC: PROLONGED OR EXCESSIVE EXPOSURE MAY RESULT IN
    ARGNA. REPEATED EXPOSURE TO CADMIUM OR NICKEL, MAY RESULT IN KIDNEY
    DAMAGE & AN INCREASED RISK OF LUNG CANCER .
Explanation of Carcinogenicity:CADMIUM & CADMIUM COMPOUNDS, IARC HAS
    DETERMINED THAT THERE IS SUFFICIENT EVIDENCE OF CARCINOGENICITY TO
    HUMANS (GROUP I). SIMILAR CARCINOGENICITY RESULTS FOR NICKEL. OSHA
    & ACGIH CONSIDER CADMIUM & C ADMIUM COMPOUNDS TO BE SUSPECT HUMAN
    CANCER HAZARD (A2). NTP LISTS CADMIUM & CERTAIN CADMIUM COMPOUNDS
    AS REASONABLY ANTICIPATED TO BE CARCINOGENIC.
Effects of Overexposure:INGESTION: MAY CAUSE ABDOMINAL PAIN, NAUSEA,
    VOMITING AND DIARRHEA. COPPER POISONING CAN RESULT IN HEMOLYTIC
    ANEMIA AND KIDNEY, LIVER AND SPLEEN DAMAGE. NOTE: INHALTION OF
    FUMES MAY CAUSE A FLU-LIKE I LLNESS CALLED METAL FUME FEVER. THE
    FIRST SYMPTOMS ARE A METALLIC TASTE, DRYNESS AND IRRITATION OF THE
    THROAT. COUGHT AND SHORTNESS OF BREATH MAY OCCUR ALONG WITH
    HEADACHE, FATIGUE, NAUSEA, VOMITING,  MUSCLE & JOINT PAIN, FEVER &
    CHILLS. THE POTENTIAL HEALTH EFFECTS DESCRIBED ANLY APPLY IF DUST
    OR FUME IS FORMED.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING MEDICAL
    CONDITIONS SUCH AS RESPIRATORY AND/OR KIDNEY AILMENTS. INDIVIDUALS
    WITH WILSON'S DISEASE ARE AT INCREASED RISK OF COPPER POISONING.

=======================  First Aid Measures  =======================

First Aid:EYE CONTACT: FLUSH EYES WITH PLENTY OF WATER. IF IRRITATION
    DEVELOPS, CALL PHYSICIAN. SKIN CONTACT: IMMEDIATELY WASH SKIN WITH
    SOAP AND PLENTY OF WATER. IF IRRITAITON PERSISTS, CALL PHYSICIAN.
    INHALAT ION: IF EXPOSED TO EXCESSIVE LEVELS OF METAL FUMES, REMOVE
    TO FRESH AIR AND SEEK MEDICAL ATTENTION. INGESTION: PROCEDURES NOT
    NORMALLY NEEDED. IF LARGE QUANTITIES ARE INGESTED, SEEK MEDICAL
    ADVICE.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE CARBON DIOXIDE, CHEMICAL FOAM OR DRY CHEMICAL.
    USE ANY MEANS FOR EXTINGUISHING SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED POSITIVE-PRESSURE
    SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NOT A FIRE OR EXPLOSION HAZARD IN SOLID
    FORM. FINELY DIVIDED DUST MAY IGNITED AND BURN RAPIDLY WHEN MIXED
    WITH AIR IN THE PROPER PROPORTIONS. TOXIC METAL FUMES MAY BE
    RELEASED IN A FIRE SITUATION.

==================  Accidental Release Measures  ==================

Spill Release Procedures:CONTAIN SPILL & SCOOP UP OR VACUUM.
    NOTIFICATION OF THE NRC (800-424-8802) MAY BE REQUIRED. REFER TO
    EPA, DOT & APPLICABLE STATE & LOCAL REGULATIONS FOR CURRENT
    RESPONSE INFORMATION. IT IS RECOMMENDED  THAT EACH USER ESTABLISH A
    SPILL PREVENTION, CONTROL & COUNTERMEASURE PLAN(SPCC). SUCH PLAN
    SHOULD INCLUDE PROCEDURES APPLICABLE TO PROPER STORAGE, CONTROL &
    CLEANUP OF SPILLS, REUSE OR DISPOSAL.

======================	Handling and Storage  ======================

Handling and Storage Precautions:WASH THOROUGHLY AFTER HANDLING. STORE
    IN A COOL, DRY LOCATION AWAY FROM INCOMPATIBLE MATERIALS. AVOID
    CONTACT WITH ANY DUSTS, MISTS OR FUMES RESULTING FROM THE USE OF
    THIS PRODUCT.
Other Precautions:DO NOT EAT, DRINK, OR SMOKE IN WORK AREA. USE ONLY
    WITH ADEQUATE VENTILATION. NOTE: CONSULT THE MOST RECENT OSHA
    CADMIUM STANDARD (1910 1027) AND ITS ATTACHMENTS, APPENDAGES, ETC
    FOR FULL REQUIREMENTS , SOME OF WHICH ARE NOT COVERED IN THIS
    MATERIAL SAFETY DATA SHEET.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:A NIOSH/MSHA APPROVED RESPIRATOR IS RECOMMENDED
    IF DUST IS GENERATED.
Ventilation:GENERAL, LOCAL EXHAUST VENTILATION AS NECESSARY TO CONTROL
    ANY AIR CONTAMINANTS TO WITHIN THEIR PEL OR TLV DURING USE OF THIS
    PRODUCT.
Protective Gloves:REFER TO ANSI/ASC Z49.1-88(SAFETY IN WELDING, CUTTING
    AND ALIED PROCESSES)
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:BODY PROTECTION AS NECESSARY TO PREVENT SKIN
    CONTACT.
Supplemental Safety and Health
REFER TO ANSI/ASC Z49, I-88 (SAFETY IN WELDING, CUTTING & ALLIED
    PROCESSES), PUBLISHED BY THE AMERICAN WLEDING SOCIETY FOR FUTHER
    INFORMATION ON THE SELECTION OF PERSONAL PROTECTIVE EQUIPMENT.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:N/D
Melt/Freeze Pt:M.P/F.P Text:607-632C
Spec Gravity:8.0-10.0
Evaporation Rate & Reference:N/A (BUAC=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:METALLIC WIRE ROD OR STRIP; ODORLESS

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS AND BASES, STRONG OXIDIZERS, ACETYLENE, AMMONIA, HYDROGEN
    PEROXIDE, MAGNESIUM METAL, AMMONIUM NITRATE, HYDROGEN SULFIDE,
    ELEMENTAL SULFUR, SELENIUM, TELLURIUM, CHLORINATED RUBBER.
Stability Condition to Avoid:NONE EXPECTED.
Hazardous Decomposition Products:TOXIC METAL OXIDES ARE EMITTED WHEN
    HEATED ABOVE THE MELTING POINT. THE AMOUNT OF THE FUME EVOLVED
    INCREASES AS THE TEMPERATURE INCREASES.

===================  Toxicological Information	===================

Toxicological Information:CADMIUM CAS NO.: 7440-43-9, 18%, LD50=225
    MG/KG RAT ORAL, LC50=NOT AVAILABLE. COPPER CAS NO.: 7440-50-8, 26%,
    LD50=3.5 MG/KG MOUSE, INTRAPERITONCAL, LC50=NOT AVAILABLE. NICKEL
    (IN 50N) CAS NO.: 7440-0 2-0, 1%, LD50=NONE. LC50=NONE. SILVER
    CAS.: 7440-22-4, 35%, LD50=NOT AVAILABLE. LC50=NOT AVAILABLE. ZINC
    (AS OXIDE) CAS NO.: 7440-66-6, 21%, LD50=7.950 MG/KG MOUSE, ORAL.
    LC50=2.500 MG/KG, MOUSE.

=====================  Ecological Information  =====================

Ecological:ECOTOXICITY: NO DATA AVAILABLE. ENVIRONMENTAL FATE:	NO DATA
    AVAILABLE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:EPA WASTE NUMBER: D006/D011. BEFORE DISPOSAL
    THIS PRODUCT OR MIXT CONTAINING THIS PRODUCT SHOULD BE TESTED FOR
    TOXICITY CHARACTERISTICS UNDER THE CURRENT EPA HAZARDOUS WASTE
    REGULATIONS TCLP TESTING P ROCEDURES 40CFRPART 261 ET SEQ.
    DISPOSAL/RECYCLING/RECLAMATION REQUIREMENTS WILL VARY BY LOCAL &
    DIS POSAL METHOD. CONSULT STATE/LOCAL AUTHORITIES.

===================  MSDS Transport Information  ===================

Transport Information:INTERNATIONAL: UN NUMBER: NOT REGULATED. UNITED
    STATES: EPA WASTE NUMBER: D006/D011. DOT CLASSIFICASTION: NOT
    REGULATED. CANADA: PIN NUMBER: NOT REGULATED. TDG CLASS: NOT
    REGULATED. EC: DGI: NOT DETER MINED.

=====================  Regulatory Information  =====================

SARA Title III Information:SARA 311 AND 312 HAZARD CATEGORIES:
    IMMEDIATE (ACUTE) HEALTH HAZARD: YES. DELAYED (CHRONIC) HEALTH
    HAZARD: YES. FIRE HAZARD: NO. REACTIVITY HAZARD: NO. REACTIVITY
    HAZARD: NO. SUDDEN RELEASE OF PRESSUR E: NO. SARA SECTION 313
    NOTIFICATION: THIS PRODUCT CONTAINS A TOXIC CHEMICAL (OR CHEMICALS)
    SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF TITLE III
    OF THE SUPERFUND AMENDMENTS & REAUTHORIZAT ION ACT OF 1986 & 40 CFR
    PART 372. CADMIUM, 7440-43-9, 16-24%; COPPER, 7440-50-8, 15-45%;
    NICKEL, 7440-02-0, 0-1%; SILVER, 7440-22-4, 20-50%; ZINC (AS
    OXIDE), 7440-66-6, 16-30%.
Federal Regulatory Information:TSCA: IN TSCA. OZONE DEPLETING
    SUBSTANCES (ODS): THIS PRODUCT NEITHER CONTAINS NOR IS MANUFACTURER
    WITH AN OZONE DEPLETING SUBSTANCE SUBJECT TO THE LABELING
    REQUIREMENTS OF THE CLEAN AIR ACT AMENDMENT S 1990 AND 40 CFR PART
    82. VOLATILE ORGANIC COMPOUNDS (VOC): NONE.
State Regulatory Information:CALIFORNIA: WARNING: THIS PRODUCT CONTAINS
    CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
    VOLATILE ORGANIC COMPOUND (CARB): NOT DETERMINED.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
013097, QUALCHEM 25567-LEAK DETECTION COMPOUND, OXYGEN SYSTE
IMP-EP-TURBINE OIL, MIL-L-17331H & AM-1, 2190 TEP 64741-88-4
HFE-71DE 3M NOVEC ENGINEERED FLUID (SEE SUPPL) 156-60-5
163702-08-7
163702-07-6
IMP-EP-TURBINE OIL, MIL-L-17331H & AM-1, 2190 TEP 64741-88-4
099, WATERBORNE SFL-SPRAY/DIP 25068-38-6
2807-30-9
1317-33-5
1309-64-4
LEAD/ACID STORAGE BATTERY 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
7440-31-5
THERMOSET LAMINATE, PHENOLIC CELLULOSE, X, XX, XXX
EPOXY PAINT (BASE) 25068-38-6
13463-67-7
14807-96-6
100-51-6
1330-20-7
100-41-4
MIL-S-46163, TYPE 1, GRADE K
599-A8574-1 PART A LIGHTING GUARD 123-86-4
1330-20-7
822-06-0
B&B 1567C
QUICK DRY GLOSS ENAMEL COLOR: #17886 WHITE 8052-41-3
TYPE I, ALIPHATIC ISOCYANATE MIL-PRF-85285C (MIL-C-85285B) 4035-89-6
3779-63-3
64742-95-6
123-86-4
763-69-9
6330CG, GENERATION 2000 PENETRATING OIL (FORMULA 318) 8052-41-3
64741-88-4
124-38-9
VORTEX MAXIMUM PERFORMANCE ORGANIC SOLVENT 68647-72-3
SOLVENT BLEND 78-93-3
141-78-6
123-86-4
123-42-2
64-17-5
TYPE II, CL C2,L.D. POLYAMIDE 78-92-2
64742-95-6
7789-06-2
TYPE II,CL C2,EPOXY 79-24-3
TYPE II, ALIPHATIC ISOCYANATE 763-69-9
28182-81-2
64742-95-6
123-86-4
107-87-9
TYPE II, POLYURETHANE 108-65-6
123-86-4
1330-20-7
100-41-4
78-93-3
123-54-6
9038-95-3
METREGRIP 303 BASE 25068-38-6
CR 4944, TURCAM INSECTICIDE 22781-23-3
7631-86-9
9084-06-4
ALLVAC 718 NICKEL BASE ALLOY 7440-47-3
1309-37-1
7439-98-7
7440-02-0
7440-25-7
7440-32-6
LEAD ACID BATTERY 7439-92-1
1309-60-0
7664-93-9
9003-07-0
9003-55-8
9002-86-2
PYROMET 625 HI - TEMP 7440-02-0
7440-47-3
1309-37-1
7440-48-4
7439-98-7
7429-90-5
13463-67-7
7440-50-8
7439-96-5
AMDRY 9155, CDS 19155 & 4192, COBALT BASE ALLOY 7440-48-4
7439-98-7
7440-47-3
7440-21-3
7439-89-6
7440-02-0
MSA P/N 481317 CALIBRATION CHECK GAS, 100% NITROGEN 7727-37-9
D-76B,AQUEOUS SOLUBLE DEVELOPER 532-32-1
NCI 019962, SODIUM NITRATE U 7631-99-4
MET-L-GL0 1400B 64771-72-8
124-38-9
FC056, CITRA-SAFE 5989-27-5
WRIGHT GIEMSA STAIN (AMES HEMATEK I & II, SEE SUPPLE DATA) 61-73-4
67-56-1
9002-93-1
68988-92-1
51811-82-6
8T9566, CAT TRANSMISSION AND DRIVE TRAIN OIL (TDTO) 10W
W & W GIEMSA STAIN BUFFER (AMES HEMATEK I & II, SEE SUPPLE) 9002-93-1
7732-18-5
10049-21-5
7778-77-0
DEOXIT D100L LIQUID 25ML (D100L-25C)
W & W GIEMSA STAIN PACK RINSE (AMES HEMATEK I & II,SEE SUPPL 7732-18-5
7778-77-0
7558-80-7
67-56-1
A162 500, LACTIC ACID 97-73-4
50-14-6
METHANE IN AIR 74-82-8
132259-10-0
98-0211-9221-0, HFE-71DE 3M NOVEC ENGINEERED FLUID 163702-08-7
163702-07-6
156-60-5
CHLOR FLOC EMERGENCY DRINKING WATER TABLETS
SILVER ALLOY 25, 25L, 30, 35, 45, 50, 50N 7440-22-4
7440-43-9
7440-50-8
LEAD/ACID STORAGE BATTERY 7664-93-9
7440-36-0
7440-38-2
7439-92-1
BATTERY ELECTROLYTE 7732-18-5
7664-93-9
ARMA-SOL WASH & DRY (PREPARED SOLUTIONS) 7732-18-5
DINITROL AV 30 108-94-1
111-76-2
64742-48-9
SILICONE POLYMER IN SOLVENT, SS4004 78-10-4
67-64-1
71-43-2
108-88-3
67-63-0
71-36-3
68554-67-6
PLIOBOND 30 50-00-0
108-95-2
78-93-3
471-34-1
PLIOBOND 30 78-93-3
471-34-1
108-95-2
50-00-0
FA1051 MMM-A-1617 TYPE II, ADHESIVE, RUBBER BASE, GENERAL PU 108-88-3
110-54-3
78-93-3
67-64-1
9010-98-4
MMM-A-1617A SOLVENTBORNE NEOPRENE ADHESIVE 108-88-3
110-54-3
67-64-1
78-93-3

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net