Search   
MSDS  
:
 AMDRY 9155, CDS 19155 & 4192, COBALT BASE ALLOY
CAS  
:
 7440-48-4
7439-98-7
7440-47-3
7440-21-3
7439-89-6
7440-02-0
NAME  
:
 cobalt
molybdenum
chromium
silicon
iron
nickel
=====================  Product Identification  =====================

MSDS NAME:AMDRY 9155, CDS 19155 & 4192, COBALT BASE ALLOY
Status Code:A
MSDS Number: CLPVF
=== Responsible Party ===
Company:SULZER METCO /WESTBURY/ INC
Address:1101 PROSPECT AVE
City:WESTBURY
State:NY
ZIP:11590-2724
Country:US
Info Phone Num:516-334-1300
Emergency Phone Num:(800)424-9300
Resp. Party Other MSDS Num.:REVISION 2
Chemtrec Ind/Phone:(800)424-9300
CAGE:01FK3
=== Contractor Identification ===
Company:SULZER METCO (US) INC
Address:1101 PROSPECT AVE
Box:City:WESTBURY
State:NY
ZIP:11590-2724
Country:US
Phone:516-334-1300
CAGE:01FK3

=============  Composition/Information on Ingredients  =============

Name:COBALT
CAS:7440-48-4
RTECS #:GF8750000
= Wt:59.
OSHA PEL:0.05 MG/M3
ACGIH TLV:0.05 MG/M3

Name:MOLYBDENUM
CAS:7439-98-7
RTECS #:QA4680000
= Wt:28.
OSHA PEL:10 MG/M3
ACGIH TLV:10 MG/M3

Name:CHROMIUM
CAS:7440-47-3
RTECS #:GB4200000
= Wt:8.
OSHA PEL:1 MG/M3
ACGIH TLV:0.5 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:SILICON
CAS:7440-21-3
RTECS #:VW0400000
= Wt:3.
OSHA PEL:10 MG/M3
ACGIH TLV:10 MG/M3

Name:IRON
CAS:7439-89-6
RTECS #:NO4565500
= Wt:1.
OSHA PEL:10 MG/M3
ACGIH TLV:5 MG/M3

Name:NICKEL
CAS:7440-02-0
RTECS #:QR5950000
= Wt:1.
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES
Health Hazards Acute and Chronic:COBALT: INHALATION MAY CAUSE
    PROGRESSIVE, DIFFUSE PNEUMONIA, RESPIRATORY SENSITIZATION
    CHARACTERIZED BY COUGH, WHEEZING AND SHORTNESS OF BREATH. INGESTION
    MAY CAUSE IRRITATION TO THE RESPIRATORY SYSTE M AND GASTROINTETINAL
    TRACT. SKIN CONTACT MAY CAUSE ALLERGIC DERMATITIS OR ECZEMA. EYE
    CONTACT MAY CAUSE IRRITATION. TARGET ORGANS: RESPIRATORY SYSTEM,
    GASTROINTESTINAL TRACT, SKIN, EYES.
Explanation of Carcinogenicity:COBALT: ACGIH CLASSIFIED A3 ANIMAL
    CARCINOGEN. CHROMIUM: HEXAVALENT CHROMIUM IS ACGIH CLASSIFIED A1
    CONFIRMED HUMAN CARCINOGEN & IARC CLASSIFICATION GROUP I CARCINOGEN
    TO HUMANS. NTP CLASSIFIED HEXAVA LENT CHROMIUM AS KNOWN TO BE
    CARCINOGENIC. NICKEL: ACGIH CLASSIFIED A1 CONFIRMED HUMAN
    CARCINOGEN. IARC CLASSIFIED GROUP I CARCINOGENIC TO HUMANS.
Effects of Overexposure:EYE CONTACT-POSSIBLE CONJUNCTIVAL IRRITATION,
    LACRIMATION. SKIN CONTACT-POSSIBLE IRRITATION, DERMATITIS, ECZEMA,
    SENSITIZATION OR CHROME LESIONS, DISCOLORATION. INHALATION-POSSIBLE
    IRRITATIOIN TO THE	RESPIRATORY SYSTEM, MUCOUS MEMBRANE IRRITATION
    OR ULCERTAION, SENSITIZATION CHARACTERIZED BY COUGH, WHEEZING,
    SHORTNESS OF BREATH, DECREASED CHEST EXPANSION & LESSENED CAPACITY
    FOR WORK. INGESTION-POS SIBLE IRRITATION TO THE RESPIRATORY SYSTEM
    & GASTROINTESTINAL TRACT, LOSS OF MUSCULAR COORDINATION, CONFUSION
    AND CONVULSIONS.
Medical Cond Aggravated by Exposure:CONSULT A PHYSICIAN.

=======================  First Aid Measures  =======================

First Aid:EYE: FLUSH EYE WITH WATER OR AT LEAST 15-20 MINUTES WHILE
    HOLDING EYELID OPEN. IF IRRITATION PERSISTS, CONSULT A PHYSICIAN.
    SKIN: WASH WITH SOAP AND WATER. IF IRRITATION PERSISTS, CONSULT A
    PHYSICIAN.	INHALATION: EXPOSE TO FRESH AIR. CONSULT A PHYSICIAN IF
    IRRITATION OR RESPIRATORY DISTRESS PERSISTS. INGESTION: CONSULT A
    PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE CLASS D FIRE EXTINGUISHER.
Fire Fighting Procedures:TREAT AS A METALLIC FIRE. USE NIOSH/MSHA
    APPROVED SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE
    CLOTHING IF INVOLVED IN A FIRE. *SILCON MAY IGNITE IF EXPOSED TO
    FLAME OR OXIDIZERS, DO NOT HEA T OR EXPOSE TO WATER.
Unusual Fire/Explosion Hazard:FINE METAL DUSTS ARE FLAMMABLE AND MAY
    EXPLODE WHEN EXPOSED TO HEAT, FLAME OR OXIDIZERS. COBALT, CHROMIUM
    AND IRON MAY IGNITE IF AIRBORNE IN THE PRESENCE OF AN IGNITION
    SOURCE OR SPONTANEOUSLY. FINE M ETAL DUSTS OF MOLYBDENUM ARE
    FLAMMABLE AND MAY EXPLODE IF EXPOSED TO HEAT, FLAME OR OXIDIZERS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VACUUM LOOSE POWDER ONLY WITH VACUUMS EQUIPPED
    HEPA FILTRATION. VACUUMS APPROPRIATE FOR USE WITH METALLIC DUSTS
    SHOULD BE UTILIZED. WIPE THE AREA CLEAN. DO NOT USE WATER FOR CLEAN
    UP OPERATIONS. DO NO T SWEEP. AVOID GENERATING AIRBORNE DUST.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AWAY FROM INCOMPATIBLES. STORE
    PRODUCT CONTAINERS IN A WELL-VENTILATED, CLEAN, COOL AND DRY AREA.
    STORE IN A MANNER TO MINIMIZE PUNCTURES AND BREAKAGE OF CONTAINERS.
Other Precautions:AVOID INGESTION, INHALATION AND EXCESSIVE SKIN
    CONTACT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:A RESPIRATOR APPROVED BY NIOSH WITH FILTER
    CARTRIDGES APPROVED FOR DUST/FUMES/MISTS SHOULD BE WORN AT ALL
    TIMES DURING THE THERMAL SPRAY PROCESS TO PROTECT THE OPERATOR FROM
    EXPOSURE TO DUST AND FUMES . RESPIRATORS MAY ALSO BE WORN WHEN
    PRODUCT HANDLING GENERATES DUST.
Ventilation:PRODUCT SHOULD BE USED WITH THE APPROPRIATE LOCAL EXHAUST
    VENTILATION PROVIDED.
Protective Gloves:ALUMINIZED GLOVES DURING PLASMA SPRAY PROCESS, RUBBER
    FOR OTHER PROCESSES.
Eye Protection:COMBUSTION SPRAYING SHADE#5, PLASMA SPRAYING UPTO 40KW
    SHADE#9, 40-60KW SHADE .
Other Protective Equipment:EYE WASH STATION(S) IS/ARE RECOMMENDED. WASH
    FACILITIES ARE RECOMMENDED. EAR PROTECTION MUST BE WORN WHEN THE
    OPERATOR IS SUBJECTED TO EXCESSIVE NOISE LEVELS.
Work Hygienic Practices:RUBBER OR OTHER APPROPIAT GLOVES MAY BE WORN AS
    NEEDED DURING OTHER PHASES OF PRODUCT HANDLING TO AVOID EXCESSIVE
    SKIN CONTACT. GOGGLES MAY BE APPROPIATE DURING OTHER PHASES OF
    PRODUCT HANDLING.
Supplemental Safety and Health
AN ALUMINIZED APRON IS TO BE WORN DURING THE PLASMA SPRAY PROCESS.
    OTHER APPROPRIATE PROTECTIVE CLOTHING MAY BE WORN AS NECESSARY
    DURING PRODUCT HANDLING TO AVOID EXCESSIVE CONTACT WITH THE SKIN.

==================  Physical/Chemical Properties  ==================

HCC:N1
Solubility in Water:INSOLUBLE
Appearance and Odor:GRAY POWDER, NO ODOR

=================  Stability and Reactivity Data  =================

SEE OTHER INFORMATION.
Hazardous Decomposition Products:OZONE & NITRIC OXIDE ARE FORMED BY
    PLASMA FLAME(SIMILAR TO WELDING FUMES). THIS ACTION IS INDEPENDENT
    OF METAL POWDER. WHEN MOLYBDENUM IS HEATED TO DECOMPOSITION, TOXIC
    FUMES OF MOLYBDENUM ARE EMITTED.
Conditions to Avoid Polymerization:WILL NOT OCCUR

===================  Toxicological Information	===================

Toxicological Information:NOT PROVIDED

=====================  Ecological Information  =====================

Ecological:NOT PROVIDED

====================  Disposal Considerations  ====================

Waste Disposal Methods:EMPTY PRODUCT CONTAINERS, PRODUCT WASTE AND
    CLEANING MEDICAL SHOULD BE STORED AND DISPOSED OF ACCORDING TO THE
    APPROPRIATE LOCAL, STATE AND FEDERAL REGULATORY GUIDELINES.

===================  MSDS Transport Information  ===================

Transport Information:NOT PROVIDED

=====================  Regulatory Information  =====================

SARA Title III Information:COBALT, CHROMIUM, NICKEL: *INDICATES TOXIC
    CHEMICAL(S) SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF
    TITLE III OF THE SUPERFUND AMENDMENTS & REAUTHORIZATION ACT (SARA)
    & SUPPLIER NOTIFICATIO N REQUIREMENTS (40 CFR PART 372).
Federal Regulatory Information:COBALT, CHROMIUM, NICKEL: +INDICATES ON
    THE LIST OF HAZARDOUS AIR POLLUTANTS THAT ARE REGULATED UNDER
    SECTION 112 OF THE EPA CLEAN AIR ACT, 1990.
State Regulatory Information:

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
013097, QUALCHEM 25567-LEAK DETECTION COMPOUND, OXYGEN SYSTE
IMP-EP-TURBINE OIL, MIL-L-17331H & AM-1, 2190 TEP 64741-88-4
HFE-71DE 3M NOVEC ENGINEERED FLUID (SEE SUPPL) 156-60-5
163702-08-7
163702-07-6
IMP-EP-TURBINE OIL, MIL-L-17331H & AM-1, 2190 TEP 64741-88-4
099, WATERBORNE SFL-SPRAY/DIP 25068-38-6
2807-30-9
1317-33-5
1309-64-4
LEAD/ACID STORAGE BATTERY 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
7440-31-5
THERMOSET LAMINATE, PHENOLIC CELLULOSE, X, XX, XXX
EPOXY PAINT (BASE) 25068-38-6
13463-67-7
14807-96-6
100-51-6
1330-20-7
100-41-4
MIL-S-46163, TYPE 1, GRADE K
599-A8574-1 PART A LIGHTING GUARD 123-86-4
1330-20-7
822-06-0
B&B 1567C
QUICK DRY GLOSS ENAMEL COLOR: #17886 WHITE 8052-41-3
TYPE I, ALIPHATIC ISOCYANATE MIL-PRF-85285C (MIL-C-85285B) 4035-89-6
3779-63-3
64742-95-6
123-86-4
763-69-9
6330CG, GENERATION 2000 PENETRATING OIL (FORMULA 318) 8052-41-3
64741-88-4
124-38-9
VORTEX MAXIMUM PERFORMANCE ORGANIC SOLVENT 68647-72-3
SOLVENT BLEND 78-93-3
141-78-6
123-86-4
123-42-2
64-17-5
TYPE II, CL C2,L.D. POLYAMIDE 78-92-2
64742-95-6
7789-06-2
TYPE II,CL C2,EPOXY 79-24-3
TYPE II, ALIPHATIC ISOCYANATE 763-69-9
28182-81-2
64742-95-6
123-86-4
107-87-9
TYPE II, POLYURETHANE 108-65-6
123-86-4
1330-20-7
100-41-4
78-93-3
123-54-6
9038-95-3
METREGRIP 303 BASE 25068-38-6
CR 4944, TURCAM INSECTICIDE 22781-23-3
7631-86-9
9084-06-4
ALLVAC 718 NICKEL BASE ALLOY 7440-47-3
1309-37-1
7439-98-7
7440-02-0
7440-25-7
7440-32-6
LEAD ACID BATTERY 7439-92-1
1309-60-0
7664-93-9
9003-07-0
9003-55-8
9002-86-2
PYROMET 625 HI - TEMP 7440-02-0
7440-47-3
1309-37-1
7440-48-4
7439-98-7
7429-90-5
13463-67-7
7440-50-8
7439-96-5
AMDRY 9155, CDS 19155 & 4192, COBALT BASE ALLOY 7440-48-4
7439-98-7
7440-47-3
7440-21-3
7439-89-6
7440-02-0
MSA P/N 481317 CALIBRATION CHECK GAS, 100% NITROGEN 7727-37-9
D-76B,AQUEOUS SOLUBLE DEVELOPER 532-32-1
NCI 019962, SODIUM NITRATE U 7631-99-4
MET-L-GL0 1400B 64771-72-8
124-38-9
FC056, CITRA-SAFE 5989-27-5
WRIGHT GIEMSA STAIN (AMES HEMATEK I & II, SEE SUPPLE DATA) 61-73-4
67-56-1
9002-93-1
68988-92-1
51811-82-6
8T9566, CAT TRANSMISSION AND DRIVE TRAIN OIL (TDTO) 10W
W & W GIEMSA STAIN BUFFER (AMES HEMATEK I & II, SEE SUPPLE) 9002-93-1
7732-18-5
10049-21-5
7778-77-0
DEOXIT D100L LIQUID 25ML (D100L-25C)
W & W GIEMSA STAIN PACK RINSE (AMES HEMATEK I & II,SEE SUPPL 7732-18-5
7778-77-0
7558-80-7
67-56-1
A162 500, LACTIC ACID 97-73-4
50-14-6
METHANE IN AIR 74-82-8
132259-10-0
98-0211-9221-0, HFE-71DE 3M NOVEC ENGINEERED FLUID 163702-08-7
163702-07-6
156-60-5
CHLOR FLOC EMERGENCY DRINKING WATER TABLETS
SILVER ALLOY 25, 25L, 30, 35, 45, 50, 50N 7440-22-4
7440-43-9
7440-50-8
LEAD/ACID STORAGE BATTERY 7664-93-9
7440-36-0
7440-38-2
7439-92-1
BATTERY ELECTROLYTE 7732-18-5
7664-93-9
ARMA-SOL WASH & DRY (PREPARED SOLUTIONS) 7732-18-5
DINITROL AV 30 108-94-1
111-76-2
64742-48-9
SILICONE POLYMER IN SOLVENT, SS4004 78-10-4
67-64-1
71-43-2
108-88-3
67-63-0
71-36-3
68554-67-6
PLIOBOND 30 50-00-0
108-95-2
78-93-3
471-34-1
PLIOBOND 30 78-93-3
471-34-1
108-95-2
50-00-0
FA1051 MMM-A-1617 TYPE II, ADHESIVE, RUBBER BASE, GENERAL PU 108-88-3
110-54-3
78-93-3
67-64-1
9010-98-4
MMM-A-1617A SOLVENTBORNE NEOPRENE ADHESIVE 108-88-3
110-54-3
67-64-1
78-93-3

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net