Material Safety Data Sheet U.S.Department of Labor
May be used comply with Occupational Safety and Health Administration
OSHA's Hazard Communication Standard (Non-Mandatory Form)
29 CFR 1910.1200. Standard must be Form Approved
consulted for specific requirements OMB No. 1218-0072
Note: Blank spaces are not permitted. If any item is not applicable, or no
IDENTITY (As Used on Label and List)
RESIST DEVELOPER RD6 information is available, the space must be marked to indicate that.
Section I
Manufacturer's Name Emergency Telephone Number
Emergency Telephone Number
Futurrex, Inc. 800-535-5053
Address ( Number, Street, City, State and ZIP Code ) Telephone Number for Information
12 Cork Hill Road 973-209-1563
Date Prepared
Franklin , New Jersey 07416 1/2/2007
Signature of Prepare ( ptional)
o
Section II - Hazardous Ingredients/Identity Information
CAS Number % (optional)
Hazardous Components (Specific Chemical Identity: Common Name(s)) OSHA PEL ACGIH TLV
*All Components of the product are registered in the Chemical Substance Inventory according with the Toxic Substance Control Act.
Section III - Physical/Chemical Characteristics.
Boiling Point Specific Gravity (H2O=1)
(掳C) 155 <1
100 1
Vapor Pressure (mm Hg) Melting Point
(20掳C) (掳C) 155
24 0
Vapor Density (AIR-1) Evaporatiion Rate
0.6 (Butyl Acetate=1) <1
Solubility in Water
Unlimited
Appearance and Odor
Clear liquid. Slight odor.
Section IV- Fire and Explosion Hazard Data
Flash Point ( Method Used ) Flammable Limits. LEL UEL
Nonflammable None None None
.
Extinguishing Media
None
Special Fire Fighting Procedures.
None
.
Unusual Fire and Explosion Hazard
None