Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: quantumchemicals_com_au---Ethoxy_Propyl_Acetate_MSDS_12-05-2005.asp
                                  ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 1 of 10




Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION


PRODUCT NAME
ETHOXY PROPYL ACETATE

SYNONYMS

C5-H6-O2, HCCCO2C2H5, "propiolic acid ethyl ester", "acetylenecarboxylic acid ethyl
ester", "propynoic acid, ethyl ester"

PROPER SHIPPING NAME
ESTERS, N.O.S.

PRODUCT USE
Intermediate.

SUPPLIER
Company: Quantum Chemicals Pty Ltd
Address:
70 Quantum Close
Dandenong South
Victoria 3175
Telephone: 03 8795 8000
Emergency Tel: 1300 131 001
Fax: 03 8795 8099


HAZARD RATINGS

Flammability
Toxicity
Body Contact
Reactivity
Chronic

SCALE: Min/Nil=0 Low=1 Moderate=2 High=3 Extreme=4


Section 2 - HAZARDS IDENTIFICATION


STATEMENT OF HAZARDOUS NATURE
HAZARDOUS SUBSTANCE. DANGEROUS GOODS. According to the Criteria of NOHSC,
and the ADG Code.
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 2 of 10
Section 2 - HAZARDS IDENTIFICATION




POISONS SCHEDULE
None

RISK SAFETY
Flammable. Do not breathe gas/ fumes/ vapour/ spray.
HARMFUL - May cause lung damage if swallowed. Wear suitable protective clothing.
Inhalation may produce health damage*. Use only in well ventilated areas.
Repeated exposure potentially causes skin Keep container in a well ventilated place.
dryness and cracking*.
Vapours potentially cause drowsiness and To clean the floor and all objects contaminated
dizziness*. by this material use water and detergent.
* (limited evidence). Keep container tightly closed.
Keep away from food drink and animal feeding
stuffs.
Take off immediately all contaminated clothing.
If swallowed IMMEDIATELY contact Doctor or
Poisons Information Centre (show this container
or label).
This material and its container must be disposed
of as hazardous waste.


Section 3 - COMPOSITION / INFORMATION ON INGREDIENTS

NAME CAS RN %
ethoxy propyl acetate 623-47-2 >98


Section 4 - FIRST AID MEASURES


SWALLOWED
For advice, contact a Poisons Information Centre or a doctor.
路 If swallowed do NOT induce vomiting.
路 If vomiting occurs, lean patient forward or place on left side (head-down position, if
possible) to maintain open airway and prevent aspiration.
路 Observe the patient carefully.
路 Never give liquid to a person showing signs of being sleepy or with reduced awareness;
i.e. becoming unconscious
路 Give water to rinse out mouth, then provide liquid slowly and as much as casualty can
comfortably drink.
路 Seek medical advice.

EYE
If this product comes in contact with the eyes:
路 Immediately hold eyelids apart and flush the eye continuously with running water.
路 Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and
moving the eyelids by occasionally lifting the upper and lower lids.
路 Continue flushing until advised to stop by the Poisons Information Centre or a doctor,
or for at least 15 minutes.
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 3 of 10
Section 4 - FIRST AID MEASURES


路 Transport to hospital or doctor without delay.
路 Removal of contact lenses after an eye injury should only be undertaken by skilled
personnel.

SKIN
If skin contact occurs:
路 Immediately remove all contaminated clothing, including footwear.
路 Flush skin and hair with running water (and soap if available).
路 Seek medical attention in event of irritation.

INHALED
路 If fumes or combustion products are inhaled remove from contaminated area.
路 Lay patient down. Keep warm and rested.
路 Prostheses such as false teeth, which may block airway, should be removed, where
possible, prior to initiating first aid procedures.
路 Apply artificial respiration if not breathing, preferably with a demand valve
resuscitator, bag-valve mask device, or pocket mask as trained. Perform CPR if necessary.
路 Transport to hospital, or doctor.

NOTES TO PHYSICIAN
Treat symptomatically.


Section 5 - FIRE FIGHTING MEASURES


EXTINGUISHING MEDIA
路 Foam.
路 Dry chemical powder.
路 BCF (where regulations permit).
路 Carbon dioxide.
路 Water spray or fog - Large fires only.

FIRE FIGHTING
路 Alert Fire Brigade and tell them location and nature of hazard.
路 May be violently or explosively reactive.
路 Wear breathing apparatus plus protective gloves for fire only.
路 Prevent, by any means available, spillage from entering drains or water course.
路 If safe, switch off electrical equipment until vapour fire hazard removed.
路 Use water delivered as a fine spray to control fire and cool adjacent area.
路 Avoid spraying water onto liquid pools.
路 DO NOT approach containers suspected to be hot.
路 Cool fire exposed containers with water spray from a protected location.
路 If safe to do so, remove containers from path of fire.
路 Equipment should be thoroughly decontaminated after use.

FIRE/EXPLOSION HAZARD
路 Liquid and vapour are flammable.
路 Moderate fire hazard when exposed to heat or flame.
路 Vapour forms an explosive mixture with air.
路 Moderate explosion hazard when exposed to heat or flame.
路 Vapour may travel a considerable distance to source of ignition.
路 Heating may cause expansion or decomposition leading to violent rupture of containers.
路 On combustion, may emit toxic fumes of carbon monoxide (CO).

FIRE INCOMPATIBILITY
Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine
bleaches, pool chlorine etc. as ignition may result.
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 4 of 10
Section 5 - FIRE FIGHTING MEASURES


HAZCHEM: 3Y


Section 6 - ACCIDENTAL RELEASE MEASURES


EMERGENCY PROCEDURES

MINOR SPILLS
路 Remove all ignition sources.
路 Clean up all spills immediately.
路 Avoid breathing vapours and contact with skin and eyes.
路 Control personal contact by using protective equipment.
路 Contain and absorb small quantities with vermiculite or other absorbent material.
路 Wipe up.
路 Collect residues in a flammable waste container.

MAJOR SPILLS
路 Clear area of personnel and move upwind.
路 Alert Fire Brigade and tell them location and nature of hazard.
路 May be violently or explosively reactive.
路 Wear breathing apparatus plus protective gloves.
路 Prevent, by any means available, spillage from entering drains or water course.
路 No smoking, naked lights or ignition sources.
路 Increase ventilation.
路 Stop leak if safe to do so.
路 Water spray or fog may be used to disperse / absorb vapour.
路 Contain spill with sand, earth or vermiculite.
路 Use only spark-free shovels and explosion proof equipment.
路 Collect recoverable product into labelled containers for recycling.
路 Absorb remaining product with sand, earth or vermiculite.
路 Collect solid residues and seal in labelled drums for disposal.
路 Wash area and prevent runoff into drains.
路 If contamination of drains or waterways occurs, advise emergency services.

PROTECTIVE ACTIONS FOR SPILL
PROTECTIVE ACTION ZONE

half
evacuation
downwind
direction
distance
down wind distance
wind isolation
distance
direction
half
evacuation downwind
INITIAL direction distance
ISOLATION
ZONE

From IERG (Canada/Australia)
Isolation Distance 25 metres
Downwind Protection Distance 300 metres
IERG Number 14

FOOTNOTES
1 PROTECTIVE ACTION ZONE is defined as the area in which people are at risk of harmful exposure. This zone
assumes that random changes in wind direction confines the vapour plume to an area within 30 degrees on
either side of the predominant wind direction, resulting in a crosswind protective action distance equal
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 5 of 10
Section 6 - ACCIDENTAL RELEASE MEASURES


to the downwind protective action distance.
2 PROTECTIVE ACTIONS should be initiated to the extent possible, beginning with those closest to the spill
and working away from the site in the downwind direction. Within the protective action zone a level of
vapour concentration may exist resulting in nearly all unprotected persons becoming incapacitated and
unable to take protective action and/or incurring serious or irreversible health effects.
3 INITIAL ISOLATION ZONE is determined as an area, including upwind of the incident, within which a high
probability of localised wind reversal may expose nearly all persons without appropriate protection to
life-threatening concentrations of the material.
4 SMALL SPILLS involve a leaking package of 200 litres (55 US gallons) or less, such as a drum (jerrican or
box with inner containers). Larger packages leaking less than 200 litres and compressed gas leaking from
a small cylinder are also considered "small spills".
LARGE SPILLS involve many small leaking packages or a leaking package of greater than 200 litres, such as
a cargo tank, portable tank or a "one-tonne" compressed gas cylinder.
5 Guide 127 is taken from the US DOT emergency response guide book.
6 IERG information is derived from CANUTEC - Transport Canada.

Personal Protective Equipment advice is contained in Section 8 of the MSDS.


Section 7 - HANDLING AND STORAGE


PROCEDURE FOR HANDLING
路 Avoid all personal contact, including inhalation.
路 Wear protective clothing when risk of exposure occurs.
路 Use in a well-ventilated area.
路 Prevent concentration in hollows and sumps.
路 DO NOT enter confined spaces until atmosphere has been checked.
路 Avoid smoking, naked lights, heat or ignition sources.
路 When handling, DO NOT eat, drink or smoke.
路 Vapour may ignite on pumping or pouring due to static electricity.
路 DO NOT use plastic buckets.
路 Earth and secure metal containers when dispensing or pouring product.
路 Use spark-free tools when handling.
路 Avoid contact with incompatible materials.
路 Keep containers securely sealed.
路 Avoid physical damage to containers.
路 Always wash hands with soap and water after handling.
路 Work clothes should be laundered separately.
路 Use good occupational work practice.
路 Observe manufacturer's storing and handling recommendations.
路 Atmosphere should be regularly checked against established exposure standards to
ensure safe working conditions.

SUITABLE CONTAINER
路 Packing as supplied by manufacturer.
路 Plastic containers may only be used if approved for flammable liquid.
路 Check that containers are clearly labelled and free from leaks.

STORAGE INCOMPATIBILITY
Avoid reaction with oxidising agents.
Avoid acids, bases, heat.

STORAGE REQUIREMENTS
路 Store in original containers in approved flame-proof area.
路 No smoking, naked lights, heat or ignition sources.
路 DO NOT store in pits, depressions, basements or areas where vapours may be trapped.
路 Keep containers securely sealed.
路 Store away from incompatible materials in a cool, dry well ventilated area.
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 6 of 10
Section 7 - HANDLING AND STORAGE


路 Protect containers against physical damage and check regularly for leaks.
路 Observe manufacturer's storing and handling recommendations.
_____________________________________________________

SAFE STORAGE WITH OTHER CLASSIFIED CHEMICALS


+ X + X 0 +
_____________________________________________________
+: May be stored together
O: May be stored together with specific preventions
X: Must not be stored together



Section 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION


EXPOSURE CONTROLS
The following materials had no OELs on our records
鈥? ethyl propiolate: CAS:623- 47- 2



MATERIAL DATA
No exposure limits set by NOHSC or ACGIH.

PERSONAL PROTECTION




EYE
路 Safety glasses.
路 Safety glasses with side shields.
路 Chemical goggles.
路 Contact lenses may pose a special hazard; soft contact lenses may absorb and
concentrate irritants. A written policy document, describing the wearing of lens or
restrictions on use, should be created for each workplace or task. This should include a
review of lens absorption and adsorption for the class of chemicals in use and an account
of injury experience. Medical and first-aid personnel should be trained in their removal
and suitable equipment should be readily available. In the event of chemical exposure,
begin eye irrigation immediately and remove contact lens as soon as practicable. Lens
should be removed at the first signs of eye redness or irritation - lens should be
removed in a clean environment only after workers have washed hands thoroughly. [CDC
NIOSH Current Intelligence Bulletin 59].

HANDS/FEET
Wear chemical protective gloves, eg. PVC.
Wear safety footwear.

OTHER
路 Overalls.
路 PVC Apron.
路 PVC protective suit may be required if exposure severe.
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 7 of 10
Section 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION


路 Eyewash unit.
路 Ensure there is ready access to a safety shower.

RESPIRATOR
Selection of the Class and Type of respirator will depend upon the level of breathing
zone contaminant and the chemical nature of the contaminant. Protection Factors (defined
as the ratio of contaminant outside and inside the mask) may also be important.

Breathing Zone Level Maximum Protection Half- face Respirator Full- Face Respirator
ppm (volume) Factor
1000 10 A- AUS -
1000 50 - A- AUS
5000 50 Airline * -
5000 100 - A- 2
10000 100 - A- 3
100+ Airline**

* - Continuous Flow ** - Continuous-flow or positive pressure demand.

The local concentration of material, quantity and conditions of use determine the type of
personal protective equipment required.
For further information consult site specific
CHEMWATCH data (if available), or your
Occupational Health and Safety Advisor.

ENGINEERING CONTROLS
General exhaust is adequate under normal operating conditions. Local exhaust ventilation
may be required in specific circumstances. If risk of overexposure exists, wear approved
respirator. Correct fit is essential to obtain adequate protection. Provide adequate
ventilation in warehouse or closed storage areas. Air contaminants generated in the
workplace possess varying "escape" velocities which, in turn, determine the "capture
velocities" of fresh circulating air required to effectively remove the contaminant.


Type of Contaminant: Air Speed:
solvent, vapours, degreasing etc., evaporating 0.25- 0.5 m/s (50- 100 f/min)
from tank (in still air).
aerosols, fumes from pouring operations, 0.5- 1 m/s (100- 200 f/min.)
intermittent container filling, low speed
conveyer transfers, welding, spray drift,
plating acid fumes, pickling (released at low
velocity into zone of active generation)
direct spray, spray painting in shallow booths, 1- 2.5 m/s (200- 500 f/min.)
drum filling, conveyer loading, crusher dusts,
gas discharge (active generation into zone of
rapid air motion)
grinding, abrasive blasting, tumbling, high 2.5- 10 m/s (500- 2000 f/min.)
speed wheel generated dusts (released at high
initial velocity into zone of very high rapid
air motion).


Within each range the appropriate value depends on:


Lower end of the range Upper end of the range
1: Room air currents minimal or favourable to 1: Disturbing room air currents
capture
2: Contaminants of low toxicity or of nuisance 2: Contaminants of high toxicity
value only.
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 8 of 10
Section 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION


3: Intermittent, low production. 3: High production, heavy use
4: Large hood or large air mass in motion 4: Small hood- local control only


Simple theory shows that air velocity falls rapidly with distance away from the opening
of a simple extraction pipe. Velocity generally decreases with the square of distance
from the extraction point (in simple cases). Therefore the air speed at the extraction
point should be adjusted, accordingly, after reference to distance from the contaminating
source. The air velocity at the extraction fan, for example, should be a minimum of 1-2
m/s (200-400 f/min) for extraction of solvents generated in a tank 2 meters distant from
the extraction point. Other mechanical considerations, producing performance deficits
within the extraction apparatus, make it essential that theoretical air velocities are
multiplied by factors of 10 or more when extraction systems are installed or used.


Section 9 - PHYSICAL AND CHEMICAL PROPERTIES


APPEARANCE
Colourless liquid; does not mix with water.

PHYSICAL PROPERTIES
Liquid.
Does not mix with water.
Floats on water.

Molecular Weight: 98.10 Boiling Range (掳C): 120
Melting Range (掳C): Not available Specific Gravity (water=1): 0.968
Solubility in water (g/L): Immiscible pH (as supplied): Not applicable
pH (1% solution): Not applicable Vapour Pressure (kPa): Not available
Volatile Component (%vol): Not available Evaporation Rate: Not available
Relative Vapour Density (air=1): >1 Flash Point (掳C): 23.33
Lower Explosive Limit (%): Not available Upper Explosive Limit (%): Not available
Autoignition Temp (掳C): Not available Decomposition Temp (掳C): Not available
State: Liquid


Section 10 - CHEMICAL STABILITY AND REACTIVITY INFORMATION


CONDITIONS CONTRIBUTING TO INSTABILITY
路 Presence of incompatible materials.
路 Product is considered stable.
路 Hazardous polymerisation will not occur.


Section 11 - TOXICOLOGICAL INFORMATION


POTENTIAL HEALTH EFFECTS

ACUTE HEALTH EFFECTS

SWALLOWED
The liquid is highly discomforting to the gastro-intestinal tract and may be harmful if
swallowed in large quantity.
Ingestion may result in nausea, pain, vomiting. Vomit entering the lungs by aspiration
may cause potentially lethal chemical pneumonitis.
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 9 of 10
Section 11 - TOXICOLOGICAL INFORMATION


EYE
The liquid is discomforting to the eyes, may cause lachrymation (tears) and is capable
of causing a mild, temporary redness of the conjunctiva (similar to wind-burn), temporary
impairment of vision and/ or other transient eye damage/ ulceration.

SKIN
The liquid may produce skin discomfort following prolonged contact. Defatting and/or
drying of the skin may lead to dermatitis.
The material may accentuate any pre-existing skin condition.

INHALED
The vapour is discomforting to the upper respiratory tract.
Inhalation of vapour may aggravate a pre-existing respiratory condition.
Inhalation hazard is increased at higher temperatures.
Inhalation of vapour may result in nausea, headache.
The main effects of simple esters are irritation, stupor and insensibility. Headache,
drowsiness, dizziness, coma and behavioural changes may occur. Respiratory symptoms may
include irritation, shortness of breath, rapid breathing, throat inflammation, bronchitis
, lung inflammation and pulmonary oedema, sometimes delayed. Nausea, vomiting, diarrhoea
and cramps are observed. Liver and kidney damage may result from massive exposures.

CHRONIC HEALTH EFFECTS
Principal routes of exposure are by accidental skin and eye contact and by inhalation of
vapours especially at higher temperatures.
No human exposure data available. For this reason health effects described are based on
experience with chemically related materials.
As with any chemical product, contact with unprotected bare skin; inhalation of vapour,
mist or dust in work place atmosphere; or ingestion in any form, should be avoided by
observing good occupational work practice.

TOXICITY AND IRRITATION
No significant acute toxicological data identified in literature search.



Section 12 - ECOLOGICAL INFORMATION

Marine Pollutant:Not Determined
No data for ethyl propiolate.


Section 13 - DISPOSAL CONSIDERATIONS

路 Consult manufacturer for recycling options and recycle where possible .
路 Consult State Land Waste Management Authority for disposal.
路 Incinerate residue at an approved site.
路 Recycle containers if possible, or dispose of in an authorised landfill.


Section 14 - TRANSPORTATION INFORMATION




Labels Required: FLAMMABLE LIQUID
ETHOXY PROPYL ACETATE
Chemwatch Material Safety Data Sheet (REVIEW)
Issue Date: 12-May-2005 CHEMWATCH 39825
NC317TCP Version No:2.0
CD 2007/3 Page 10 of 10
Section 14 - TRANSPORTATION INFORMATION


HAZCHEM: 3Y

UNDG:
Dangerous Goods Class: 3 Subrisk: None
UN Number: 3272 Packing Group: III
Shipping Name:ESTERS, N.O.S.

Air Transport IATA:
ICAO/IATA Class: 3 ICAO/IATA Subrisk: None
UN/ID Number: 3272 Packing Group: III
Special provisions: A3
Shipping Name: ESTERS N.O.S.

Maritime Transport IMDG:
IMDG Class: 3 IMDG Subrisk: None
UN Number: 3272 Packing Group: III
EMS Number: F- E, S- D Special provisions: 274 944
Marine Pollutant: Not Determined
Shipping Name: ESTERS, N.O.S.


Section 15 - REGULATORY INFORMATION


POISONS SCHEDULE: None

REGULATIONS
ethyl propiolate (CAS: 623-47-2) is found on the following regulatory lists;
Australia Inventory of Chemical Substances (AICS)



Section 16 - OTHER INFORMATION


Classification of the preparation and its individual components has drawn on official and
authoritative sources as well as independent review by the Chemwatch Classification
committee using available literature references.

This document is copyright. Apart from any fair dealing for the purposes of private study, research, review or
criticism, as permitted under the Copyright Act, no part may be reproduced by any process without written permission
from CHEMWATCH. TEL (+61 3) 9572 4700.

Issue Date: 12-May-2005
Print Date: 19-Dec-2007

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
pshcanada_com---06_GLAZE_MULBERRY.asp 65997-18-4 1344-28-1 12401-86-4 1305-78-8 60676-86-0 1303-86-2 68187-12-2 14808-60-7 21651-19-4 1308-38-9 1308-06-1
pshcanada_com---UG_Lime.asp 112945-52-5 1317-65-3 7440-48-4 14808-60-7 14807-96-6 7440-67-7
pulseinstruments_net---msds_ph4.asp 877-24-7 121-54-0 7732-18-5
pureline_com---PureLine_MSDS_-_PureCide25_071504.asp 7758-19-2 7647-14-5 7775-09-9 7757-82-6 7732-18-5
puritanproducts_com---DIMETHYLANILINE_MSDS_040307.asp 121-69-7
puritanproducts_com---PERCHLORIC_ACID_60-70_MSDS.asp 7601-90-3 7732-18-5
puritanproducts_com---SULFURIC_ACID_FUMING_20_MSDS_081805.asp 8014-95-7 7664-93-9 7446-11-9
pyrochem_com---PC200065.asp 690-39-1
pyrochem_com---PC98184.asp 144-55-8 471-34-1 66071-81-6 12001-26-2 7631-86-9
pyrochem_com---Water_Ext_MSDS_Letter.asp N/A
qcconstructionproducts_com---MSDS-_PS_Adobe.asp 7647-01-0 7789-12-0 7773-01-5
qorpak_com---375167.asp 7732-18-5 12054-85-2
qorpak_com---375168.asp 7647-01-0 12054-85-2 7803-55-6 7732-18-5
qorpak_com---375179.asp 7732-18-5 76-60-8 845-10-3
qorpak_com---375181.asp 7732-18-5 62625-28-9
qorpak_com---375190.asp 7732-18-5 569-61-9 64-17-5 108-95-2 67-56-1 67-63-0
qorpak_com---375231.asp 7732-18-5 10034-96-5
qorpak_com---375290.asp 7732-18-5 87-69-4
qorpak_com---375301.asp 7732-18-5 7446-20-0
qorpak_com---375312.asp 7732-18-5 76-03-9
qorpak_com---375364.asp 7732-18-5 28300-74-5 67-66-3
quabieu_com---Super_Shiney.asp N/A
quabieu_com---Toughen_Up.asp N/A
quakewrap_com---QB-J200TC-A.asp 25085-99-8 112945-52-5 2461-15-6 106-89-8 1333-86-4 64742-47-8
quantumchemicals_com_au---Acrylic_Acid_MSDS_16-08-2006.asp N/A
quantumchemicals_com_au---Borax_Decahydrate_MSDS_09-11-2006.asp 12447-40-4 61028-24-8
quantumchemicals_com_au---CetylStearylAlcohol_MSDS_Sept2004.asp N/A
quantumchemicals_com_au---DPTA_Masquol_MSDS_12-05-2005.asp N/A
quantumchemicals_com_au---Ethoxy_Propyl_Acetate_MSDS_12-05-2005.asp N/A
quantumchemicals_com_au---Potassium_Carbonate_MSDS_22-05-2006.asp N/A
quidel_com---8012_metra_bap.asp 1310-73-2 124-68-5
quiplabs_com---G.L.P.C-Alkaline_MSDS.asp 7732-18-5 1310-73-2 64-02-8
quiplabs_com---Versa-Terg_MSDS.asp 7732-18-5 7320-34-5 7758-29-4 9016-45-9 68584-22-5
quixtar_com---2863_USA_ES_Glister_Antiplaque_Oral_Rinse.asp 21-12-2 64-17-5 128-44-9 6004-24-6
radiatorspecialty_com---L616.asp 95-63-6 8052-41-3 124-38-9 108-67-8 64742-52-5 127-18-4
radiatorspecialty_com---M4412.asp 112-34-5 111-46-6 111-90-0 6881-94-3 25322-68-3 9004-77-7 9004-74-4
radiatorspecialty_com---M4532.asp 80-05-7 111-77-3 106008-94-0 25322-68-3 9004-77-7 106008-93-9
radioshack_com---2300965C_MSDS.asp 2006-12-1 7440-43-9 1306-19-0 21041-95-2 7440-48-4 1307-96-6 21041-93-0 1310-65-2 7440-02-0 1313-99-1 12054-48-7 1310-58-3 1310-73-2
ravenlabs_com---msds-prochemeo.asp 98-92-0 54-85-3 1408-96-6
rcbs_com---RCBSRifleLubricant.asp 8012-89-3
reagents_com---2-19185.asp 14552-35-3 7732-18-5
reagents_com---2-19405.asp 91-17-8 119-64-2
reagents_com---2-19407.asp 124-18-5
reagents_com---5230.asp 7732-18-5 1465-25-4
reagents_com---7-34021.asp 7647-14-5 64-19-7 1310-73-2 123333-90-4 7732-18-5
reagents_com---N-1030.asp 64-17-5 67-56-1 141-78-6 67-63-0 7697-37-2 7732-18-5
reagent_co_uk---FERROIN_INDICATOR_SOLUTION.asp 66-71-7 7782-63-0
reagent_co_uk---HNB_SOLUTION_1_percent_W_V.asp 165660-27-5
reanal-labor_hu---0712101.asp 585-99-9 06-80-2
reanal-labor_hu---3497101.asp 10026-06-9 06-80-2

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC