Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: unifrax_com_au---insulfrax_pumpable_xj.asp
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

1. IDENTIFICATION OF MATERIAL & SUPPLIER

Brand Name: Insulfrax庐 Pumpable

Ship. Name (CSN): None Allocated

Other Names: Insulfrax庐 Pumpable XJ
Insulfrax庐 XJ-1

UN Number: None allocated
DG Class None allocated
Packaging Group None allocated
Hazchem Code None allocated
Poisons Schedule Not scheduled
Product Use High Temperature expansion joint mastic, insulating gap
filler.

Manufacturer/Supplier: Unifrax Limited Unifrax Australia Pty. Ltd.
Mill Lane, Rainford 336 Settlement Road
St. Helens Thomastown 3074
Merseyside 20 WA118L Victoria
UK Australia


Contact Details: See Page 9.

2. HAZARDS IDENTIFICATION
Flammability
Fire Hazards: Non flammable

Explosive Hazards: Non Explosive

Health Hazards: Irritating to eyes, skin, respiratory system and disturbances
to Gastro intestines.


Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 1
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

3. COMPOSITION AND INFORMATION ON INGREDIENTS

Ingredients: Name CAS Proportion
Water 7732-18-5 0-60%
Amorphous alkaline earth
silicate fibre (Glass oxide) 65997-17-3 5-15%
(Glass oxide)
Silicon Dioxide (amphorous) 7631-86-9 10-
20%
Cellulose derivative 9032-42-2 1-7%

Other Information Remaining components not determined to be hazardous
and/or hazardous components present at less than 1.0%
(0.1% for Worksafe Australia Cat. 1 & 2 carcinogens).


4. FIRST AID MEASURES

Ingestion Ingestion is unlikely, but if it does occur DO NOT induce
vomiting; drink plenty of water. Material should be
excreted naturally, but if effects persists seek medical
attention.

Eye Flush immediately with large amounts of water for at least
15 minutes, after removing any contact lenses. Eyelids
should be held away from the eyeball to ensure thorough
rinsing. Do not rub eyes. Seek medical advice as good
work hygiene practice in all cases of eye contamination.

Skin If skin becomes irritated, remove contaminated clothing.
Wash area of contact thoroughly with soap and water. Do
not rub or scratch exposed skin. Using a skin cream or
lotion after washing may be helpful. If effects persist seek
medical advice.


Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 2
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

4. First Aid Measures cont鈥檇:

Inhalation Remove exposed person/s from source of exposure, to
fresh air. Recovery should be rapid, but if effects persist
seek medical advice.

First Aid Facilities Eyewash station and normal washroom facilities must be
provided.

Advice to Doctor Acute effects are essentially irritant in nature. Refer to
'OTHER INFORMATION' section for chronic and long term
exposures.


5. FIRE FIGHTING MEASURES.

Fire Explosion Hazard: Not Flammable and not explosive.

Hazardous Reactions/ Refer to SAFE HANDLING INFORMATION
Decomposition Products

Hazchem Code: None Allocated.


6. ACCIDENTAL RELEASE MEASURES

Spills: Pick up large dried pieces and place in containers. Where
possible, use vacuum cleaner to clean up smaller spilled
material. Refer to removal procedures in use and handling.




Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 3
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

7. HANDLING & STORAGE

Storage Precautions: Keep dry. No special storage or transport requirements.

Handling:
In the installation of Insulfrax Pumpable, the following handling and installation
procedures are recommended:
a) All installation practices should be designed to minimise
the liberation of any airborne fibre or dust.
b) In large installations of several days/weeks duration, the
installation area should be clearly designated and
barriers erected to limit access.
c) The Insulfrax Pumpable Materials should be stored in
sealed drums or similar containers until installation is to
proceed. These containers should be opened within the
designated work area when work is to start.
d) Where possible, materials should be delivered in sizes
such that a minimum of handling is required. However
when cutting or drilling is required, these should be
done with hand tools fitted with local exhaust
extraction.
e) Empty storage bags should be folded and stored in a
waste container along with any waste material.
f) Upon completion of the job, all excess materials should
be sealed in bags prior to removal from the designated
work area. The work area should be vacuumed using
an industrial vacuum cleaner. Wet mopping and wiping
can be utilised if an industrial vacuum cleaner is not
available.

In the removal of Insulfrax Pumpable materials the following procedures are
recommended:
a) All installation practices should be designed to minimise
the liberation of any airborne fibre or dust.


Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 4
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

7. Handling & Storage cont鈥檇:

b) In large installations of several days/weeks duration, the
installation area should be clearly designated and
barriers erected to limit access.
c) Upon completion of the job, all excess materials should
be sealed in bags prior to removal from the designated
work area. The work area should be vacuumed using
an industrial vacuum cleaner. Wet mopping and wiping
can be utilised if an industrial vacuum cleaner is not
available.
d) With prolonged operations above the recommended use
limit of 1000oC, a small proportion of Insulfrax may
transform to Wollastonite and disordered cristobalite
warranting higher levels of dust control and respiratory
protection.

8. EXPOSURE CONTROLS & PERSONAL PROTECTION

Exposure Limits - Dry Product

0.5 fibre/ml for SMF; 2mg/m3 fumed silica (respirable dust);
Other Exposure Info.
3
10mg/m calcium aluminate cement (inspirable dust),
(NOHSC 1995)

Personal Protection: The National Code of Practice for the Safe Use of Synthetic
Mineral Fibres (NOHSC 1990) advises the use of the
following PPE that for installation and removal of both
bonded and unbonded glasswool materials.
a) Disposable coveralls or long sleeve, loose fitting clothing
and gloves (launderable clothing should be washed
separately from other clothing).
b) Where overhead work is involved, goggles and head
covering should be worn; and


Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 5
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

8. Exposure Controls & Personal Protection cont鈥檇:

c) A half-face (P1 or P2) respirator should be worn during
work in enclosed or poorly ventilated spaces, or where
evidence suggests that respirable fibre levels may
exceed 0.5 f/ml.
All respiratory devices should be tested for compliance
with AS/NZS 1715 & AS/NZS 1716.



9. PHYSICAL & CHEMICAL PROPERTIES

Appearance Off-White fibrous paste, with no odour.
Melting Point Not available
Boiling Point Not applicable
Vapor Pressure Not applicable
Specific Gravity Not available
Flash Point None
Flamm. Limit UEL Not applicable
Volatile Component Not applicable
Solubility in Water Not available

OTHER PROPERTIES

Autoignition Temp. None
Vapor Density Not applicable
pH Value 5-6
Specific Properties or Risk See 'Health Effects' section
Formula Not applicable: Mixture
Molecular Weight Not applicable: Mixture




Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 6
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

10. STABILITY & REACTIVITY

Stability: Stable under normal conditions of use.

Hazardous Reactions Refer to SAFE HANDLING INFORMATION
Decomposition Products



11. TOXICOLOGICAL INFORMATION

Remaining components not determined to be hazardous and/or hazardous components
present at less than 1.0% (0.1% for Worksafe Australia Cat. 1 & 2 carcinogens).



12. ECOLOGICAL INFORMATION


Not available


13. DISPOSAL CONSIDERATIONS

Waste Disposal: Waste should be placed in containers, plastic bags or other
methods which prevent fibre or dust emission, and
disposed of in accordance with the local waste disposal
authority requirements. There may be specific regulations
at the Local, State or Federal level that pertain to this
material.




Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 7
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.

14. TRANSPORT INFORMATION

No special transport requirements are necessary.

UN Number None Allocated
Shipping Name None Allocated
DG Class None Allocated
Packaging Group None Allocated
Hazchem Code None Allocated
Poisons Schedule Not Scheduled
Product Use High Temperature expansion joint mastic, insulating gap
filler


15. REGULATORY INFORMATION

Risk Statement: R40 (3) Possible risk of irreversible effects. R36/37/38
Irritating to eyes, respiratory system and skin.

Safety Statement: S22 Do not breathe dust. S52 Avoid contact with eyes. S38
In insufficient ventilation, wear suitable respiratory equipment.
S40 To clean floor and all objects contaminated by this
Material, use AS approved HEPA fitted vacuum cleaner.
S36/37/39 Wear suitable protective clothing, gloves and eye/
Face protection.

Hazard Category: Harmful, irritant.

Poisons Schedule: Not scheduled.




Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 8
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
INSULFRAX庐 PUMPABLE XJ
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176



MATERIAL SAFETY DATA SHEET
No Classification under EEC Directive 76/548/EEC
Refer Worksafe Australia Classifying Clause 1.14.


16. OTHER INFORMATION

Contact: During Business Hours Ph: +61 3 9463 0000

Customer Service Toll Free: Ph: 1300 797 888

Emergency / After Hours Contact: Alan Smith

Ph: 0409 288 916




References: Replaces MSDS dated 27 March 2007.



NOTICE: The information presented herein is based on data considered to be accurate as
of the date of preparation of this Material Safety Data Sheet. However, no
warranty or representation, express or implied, is made as to the accuracy or
completeness of the foregoing data and safety information, nor is any
authorisation given or implied to practise any patented invention without licence.
In addition, no responsibility can be assumed by the vendor for any damage or
injury resulting from abnormal use, from any failure to adhere to recommended
practices, or from any hazards inherent in the nature of the product.




鈥︹?nd of Report鈥︹??




Authorised by: Alan Smith
Version: 1.3
Control Status: Controlled Document
Created on: 01/08/07 9

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
unifrax_com_au---fiberfrax.asp N/A
unifrax_com_au---fiberfrax_duraboard.asp N/A
unifrax_com_au---fiberfrax_duraboard_1400_&_1600.asp N/A
unifrax_com_au---fiberfrax_paper.asp N/A
unifrax_com_au---fibermax.asp N/A
unifrax_com_au---fiber_adhesive.asp N/A
unifrax_com_au---fibrestick.asp N/A
unifrax_com_au---fyre_putty.asp N/A
unifrax_com_au---gc90.asp 65997-17-3 7631-86-9 1344-28-1 1305-78-8
unifrax_com_au---insulfrax.asp N/A
unifrax_com_au---insulfrax_blok.asp N/A
unifrax_com_au---insulfrax_board.asp N/A
unifrax_com_au---insulfrax_lds_moldable.asp 7631-86-9 65997-17-3
unifrax_com_au---insulfrax_moist_pak.asp 7732-18-5 65997-17-3 7631-86-9
unifrax_com_au---insulfrax_paper_ft.asp N/A
unifrax_com_au---insulfrax_pumpable_xj.asp N/A
unifrax_com_au---insulfrax_variform.asp N/A
unifrax_com_au---isofrax.asp N/A
unifrax_com_au---isofrax_board.asp N/A
unifrax_com_au---isofrax_paper_.asp N/A
unifrax_com_au---isofrax_pump.asp N/A
unifrax_com_au---kub_cement.asp 1344-28-1 65997-16-2 7631-86-9 13983-17-0
unifrax_com_au---launder_repair.asp 7631-86-9 65997-17-3
unifrax_com_au---moist_pac_d.asp N/A
unifrax_com_au---pumpable_xj.asp N/A
unifrax_com_au---rigidiser.asp N/A
unifrax_com_au---rigifrax.asp 083-99-7 1393-17-0
unifrax_com_au---topcoat_m.asp N/A
unifrax_com_au---variform_castable.asp N/A
unifrax_com_au---zircon_wash.asp N/A
unitex-epoxy_com---hydraulic_cement.asp N/A
unitex-epoxy_com---multipurpose_grout.asp N/A
unitex-epoxy_com---qickset_20.asp N/A
utdallas_edu---ar_msds.asp 7440-37-1
utdallas_edu---bcl3_msds.asp 10294-34-5
utdallas_edu---cf402_msds.asp 7782-44-7
utdallas_edu---cf4_msds.asp 75-73-0
utdallas_edu---ch4_msds.asp 74-82-8
utdallas_edu---cl2_msds.asp 7782-50-5
utdallas_edu---compressedair_msds.asp 132259-10-0
utdallas_edu---d2_msds.asp 7782-39-0
utdallas_edu---dcs_msds.asp 4109-96-0
utdallas_edu---fg_msds_nonflam.asp 1333-74-0 7727-37-9
utdallas_edu---h2_msds.asp 1333-74-0
utdallas_edu---he_msds.asp 7440-59-7
utdallas_edu---n2o_msds.asp 10024-97-2
utdallas_edu---n2_msds.asp 7727-37-9
utdallas_edu---nh3_msds.asp 7664-41-7
utdallas_edu---no_msds.asp 10102-43-9
utdallas_edu---o2_msds.asp 7782-44-7

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC