1. IDENTIFICATION OF MATERIAL & SUPPLIER
Fiberfrax庐
Brand Name:
None Allocated
Ship. Name (CSN):
Rigidiser
Product Names:
Hardener
Other Names:
Foamfrax Binder A
None Allocated
UN Number:
None Allocated
DG Class
None Allocated
Packaging Group
None Allocated
Hazchem Code
Not Scheduled
Poisons Schedule
Refractory Binder.
Product Use
Unifrax Australia Pty. Ltd.
Supplier:
See Page 7
Contact:
2. HAZARDS IDENTIFICATION
Flammability
Non flammable
Fire Hazards:
Non explosive
Explosive Hazards:
Irritating to eyes, skin, respiratory system and disturbances to
Health Hazards:
gastro intestines.
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 1
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
FIBERFRAX庐 RIGIDISER
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176
MATERIAL SAFETY DATA SHEET
Classified as Hazardous according to criteria of Worksafe Australia
3. COMPOSITION AND INFORMATION ON INGREDIENTS
Ingredients Name CAS Proportion
Amorphous silica 7631-86-9 14.5 - 50%
Water 7732-18-5 50 - 85%
Titratable Alkali (as Na20) 0.10 - 0.58%
4. FIRST AID MEASURES
If swallowed, give 2 glasses of water immediately and induce
Ingestion
vomiting. Seek medical advice.
Hold eye open and irrigate continuously for at least 15
Eye
minutes. Seek medical advice.
Wash affected areas with copious quantities of water.
Skin
If large amounts are inhaled remove to fresh air. If not
Inhalation
breathing give artificial respiration. If breathing is difficult give
oxygen. Lay person down, keep warm and rested. Ensure
passageway is clear, seek medical advice.
No special requirements.
First Aid Facilities
Treat symptomatically.
Advice to Doctor
5. FIRE FIGHTING MEASURES.
Not Flammable and not explosive.
Fire Explosion Hazard:
Refer to SAFE HANDLING INFORMATION
Hazardous Reactions/
Decomposition Products
None Allocated.
Hazchem Code:
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 2
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
FIBERFRAX庐 RIGIDISER
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176
MATERIAL SAFETY DATA SHEET
Classified as Hazardous according to criteria of Worksafe Australia
6. ACCIDENTAL RELEASE MEASURES
If spillage occurs in a confined space ensure adequate
Spills:
ventilation.
Contain all spills within a bund. Contain / prevent
contamination of drains and waterways. Use sand, earth or
Vermiculite to contain spillage. Treatment, storage,
transportation and disposal of waste must be in accordance
with applicable Federal, State and local regulatory
requirements.
7. HANDLING & STORAGE
SAFE HANDLING INFORMATION
Wear rubber or PVC gloves conforming to AS2161.
Handling:
Chemical goggles conforming to AS1336 and AS1337.
Keep containers tightly closed when not in use. Store at
Storage
temperatures above 20 C to avoid irreversible precipitation of
silica.
Do NOT store with food, drink or tobacco in areas where they
may become contaminated with this material.
8. EXPOSURE CONTROLS & PERSONAL PROTECTION
None established for the formulated substance.
Exposure Limits
Dust resulting from dried product spills or deposits may be
considered to be amorphous silica.
Amorphous Silica:
Worksafe TWA : 2mg/m3 respirable dust
Worksafe STEL : none established
: 10 mg/m3 total dust
TLV (ACGIH)
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 3
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
FIBERFRAX庐 RIGIDISER
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176
MATERIAL SAFETY DATA SHEET
Classified as Hazardous according to criteria of Worksafe Australia
8. Exposure Controls & Personal Protection cont鈥檇:
Ensure adequate ventilation to conform with exposure
Engineering Controls:
standard.
Wearing of the following personal protective equipment is
Personal Protection:
recommended.
Rubber or PVC gloves conforming to AS2161.
Chemical goggles conforming to AS1336 and AS1337.
9. PHYSICAL & CHEMICAL PROPERTIES
Blue or Cloudy liquid
Appearance
100掳 at 101.3 kPa
C
Boiling/Melting Point
24 mm Hg at 25 deg C
Vapour Pressure
1.21 鈥? 1.40
Specific Gravity
8.4 鈥? 10.4
Ph
None
Flash Point / Limit
Corrosiveness
Completely soluble.
Solubility in Water(g/L)
10. STABILITY & REACTIVITY
Stable under normal conditions of use.
Stability:
Refer to SAFE HANDLING INFORMATION
Hazardous Reactions
Decomposition Products
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 4
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
FIBERFRAX庐 RIGIDISER
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176
MATERIAL SAFETY DATA SHEET
Classified as Hazardous according to criteria of Worksafe Australia
11. TOXICOLOGICAL INFORMATION
HUMAN DATA
The alkalinity of this product could cause a chemical
Irritant Properties:
irritation to the skin and eyes if prolonged and repeated
contact.
None expected in the normal use of the product, when the
Respiratory Effects:
product has dried and during removal situations there is
the potential for dust generation, which can affect pre-
existing respiratory conditions. The amorphous silica used
to produce this product is of low acute toxicity, it is not
classed as carcinogenic or genotoxic
12. ECOLOGICAL INFORMATION
This material must not be disposed into drains or water causes.
13. DISPOSAL CONSIDERATIONS
Disposal of waste must be in accordance with applicable Federal, State and local
regulatory requirements.
14. TRANSPORT INFORMATION
No special transport requirements are necessary.
None Allocated
UN Number
None Allocated
Shipping Name
None Allocated
DG Class
None Allocated
Packaging Group
None Allocated
Hazchem Code
Not Scheduled
Poisons Schedule
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 5
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
FIBERFRAX庐 RIGIDISER
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176
MATERIAL SAFETY DATA SHEET
Classified as Hazardous according to criteria of Worksafe Australia
15. REGULATORY INFORMATION
Irritating to eyes, respiratory system and skin.
Risk Statement:
S22 Do not breathe dust. S52 Avoid contact with eyes. S38
Safety Statement:
In insufficient ventilation, wear suitable respiratory equipment.
S40 To clean floor and all objects contaminated by this
Material, use AS approved HEPA fitted vacuum cleaner.
S36/37/39 Wear suitable protective clothing, gloves and eye/
face protection.
Harmful, irritant.
Hazard Category:
Not scheduled.
Poisons Schedule:
16. OTHER INFORMATION
RCF DEVITRIFICATION
As produced, all RCG fibers are vitreous (glassy) materials which do not contain crystalline silica.
Continued exposure to elevated temperatures may cause these fibers to devitrify (become
crystalline). The first crystalline formation (mullite) begins to occur at approximately 985掳 C
(1805掳 F). Crystalline phase silica may begin to form at temperatures of approximately 1200掳 C
(2192掳 F). The occurrence and extent of crystalline phase formation is dependent on the duration
and temperature of exposure, fiber chemistry and/or the presence of fluxing agents. The
presence of crystalline phases can be confirmed only through laboratory analysis of the 鈥渉ot face鈥?
fiber.
IARC鈥檚 evaluation of crystalline silica states 鈥淐rystalline silica inhaled in the form of quartz or
cristobalite from occupational sources is carcinogenic to humans (Group 1)鈥? and additionally
notes 鈥渃arcinogenicity in humans was not detected in all industrial circumstances studied鈥? (IARC
Monograph Vol. 68, 1997). NTP lists all polymorphs of crystalline silica amongst substances
which may 鈥渞easonably be anticipated to be carcinogens鈥?.
IARC and NTP did not evaluate after-service RCF, which may contain various crystalline phases.
However, an analysis of after-service RCF samples obtained pursuant to an exposure monitoring
agreement with the USEPA, found that in the furnace conditions sampled, most did not contain
detectable levels of crystalline silica. Other relevant RCF studies found that (1) simulated after-
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 6
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
FIBERFRAX庐 RIGIDISER
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176
MATERIAL SAFETY DATA SHEET
Classified as Hazardous according to criteria of Worksafe Australia
service RCF showed little, or no, activity where exposure was by inhalation or by intraperitoneal
injection; and (2) after-service RCF was not cytotoxic to macrophage-like cells at concentrations
up to 320 g/cm虏 - by comparison, pure quartz or cristobalite were significantly active at much
lower levels (circa 20 g/cm虏).
CONTACT DETAILS:
+61 3 9463 0000
Contact: During Business Hours Ph:
Customer Service Toll Free: Ph: 1300 797 888
Emergency / After Hours Contact: Alan Smith
Ph: 0409 288 916
References: Replaces MSDS dated 27 March 2007.
NOTICE: The information presented herein is based on data considered to be accurate
as of the date of preparation of this Material Safety Data Sheet. However, no
warranty or representation, express or implied, is made as to the accuracy or
completeness of the foregoing data and safety information, nor is any
authorisation given or implied to practise any patented invention without
licence. In addition, no responsibility can be assumed by the vendor for any
damage or injury resulting from abnormal use, from any failure to adhere to
recommended practices, or from any hazards inherent in the nature of the
product.
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 7
Unifrax Australia Pty. Ltd.
326 Settlement Road
Thomastown, VIC 3074
FIBERFRAX庐 RIGIDISER
ACN 093 625 757
Ph: (03) 9463 0000 Fax: (03) 9464 1176
MATERIAL SAFETY DATA SHEET
Classified as Hazardous according to criteria of Worksafe Australia
... End Of Report ...
Authorised by: Alan Smith
Version: 1.4
Control Status: Controlled Document
Created on: 01/08/07 8
|