Western Poly Page 2 of 4
SYNERGISTIC No information available.
PRODUCTS:
SECTION IV: FIRST AID MEASURES
SKIN CONTACT: No first aid measures required
EYE CONTACT: Flush with gently flowing warm water until particles are dislodged. If
irritation persists, obtain medical attention.
INGESTION: Not toxic. If symptoms develop, obtain medical attention.
INHALATION: If symptoms develop, move victim to fresh air. Apply oxygen or
artificial respiration if required. If breathing difficulties or distress
continues obtain medical attention.
SECTION V: PHYSICAL DATA
APPEARANCE AND ODOUR: Clear film or pellets; odourless
SPECIFIC GRAVITY: Not available
Not available
BOILING POINT ( C):
160
MELTING POINT ( C):
SOLUBILITY IN WATER: Insoluble pH: Not applicable
PERCENT VOLATILE BY VOLUME: Not available
VAPOUR PRESSURE (mmHg): Not available
VAPOUR DENSITY (air = 1): Not available
BULK DENSITY: Not available
SECTION VI: FIRE AND EXPLOSION HAZARD DATA
FLASH POINT: Not applicable
FLAMMABLE LIMITS: Not applicable
EXTINGUISHING MEDIA: Water, foam, dry chemical, CO2.
SPECIAL FIRE FIGHTING Self-contained breathing apparatus required for fire
PRODCEDURES: fighting personnel. Move containers from fire area,
or cool with water spray, if possible.
UNUSUAL FIRE AND Material will burn. Avoid spraying water directly on
EXPLOSION HAZARDS: molten material to prevent splashing and spread of
fire.
SECTION VII: REACTIVITY DATA
STABILITY: STABLE [XX] UNSTABLE [ ]
INCOMPATIBILITY Avoid heat, open flames and other sources of
(CONDITIONS TO AVOID): ignition.
Western Poly Page 3 of 4
CONDITIONS OF REACTIVITY: None known.
HAZARDOUS DECOMPOSITION Oxides of carbon and HCl.
PRODUCTS:
HAZARDOUS POLYMERIZATION: WILL NOT OCCUR [XX] MAY OCCUR [ ]
SECTION VIII: PREVENTATIVE MEASURES
SPECIAL PROTECTION INFORMATION
RESPIRATORY PROTECTION: None required under normal conditions of use.
VENTILATION: None required under normal conditions of use. If
dusting conditions occur, use local exhaust
ventilation to maintain TLV鈥檚.
PROTECTIVE GLOVES: None required.
EYE PROTECTION: Safety glasses with side-shields suggested.
OTHER PROTECTIVE EQUIPMENT Protective clothing and footwear should be worn.
(Specify): Ensure that safety shower and eyewash station are
available.
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING
Avoid ingestion. Practice reasonable caution and personal cleanliness. Avoid skin and eye
contact. Store in cool dry area away from heat and sources of ignition. If heated during use take
precautions to avoid contact and inhalation of vapours.
STEPS TO BE TAKEN IN CASE THE MATERIAL IS SPILLED OR RELEASED
Use appropriate safety equipment. Eliminate ignition sources. Spillage should be swept-up or
vacuumed immediately to prevent a slip hazard. Collect uncontaminated material for
repackaging. Collect contaminated material in approved containers for disposal. Prevent
material from entering storm sewers and public waterways.
WASTE DISPOSAL METHOD
Dispose in accordance with federal, provincial, and local regulations. This product can be
landfilled in many areas; check with local operator. It is the responsibility of the end-user to
determine if material meets the criteria of hazardous waste at the time of disposal. Empty
packaging must be disposed of, or recycled, in accordance with local regulations.
SECTION IX: PREPARATION
THE INFORMATION CONTAINED HEREIN IS GIVEN IN GOOD FAITH,
BUT NO WARRANTY, EXPRESSED OR IMPLIED, IS MADE.
DATE ISSUED: December 3, 2003 BY: Product safety committee
SUPERSEDES: December 20, 2001
Western Poly Page 4 of 4
Diversity Technologies Corp. is the parent company of
Canamara-United Supply, Hollimex Products and The Drilling Depot.
|