                                 MATERIAL SAFETY DATA SHEET
SECTION 1 - PRODUCT IDENTIFICATION AND USE
PRODUCT IDENTIFICATION NUMBER (PIN):
PRODUCT IDENTIFIER

Oil of Fennel (Natural) OF100X
PRODUCT USE

MANUFACTURERS NAME: SUPPLIERS NAME:
Xenex Labs XENEX LABORATORIES INC.
STREET ADDRESS: STREET ADDRESS:
2402 CANOE AVENUE
CITY: PROVINCE: CITY: PROVINCE:
COQUITLAM B.C.
POSTAL CODE: EMERGENCY TELEPHONE NO: POSTAL CODE: EMERGENCY TELEPHONE NO:
SPE100 V3K 6C2 (CHEMTREC) 1-800-424-9300
SECTION 2 - HAZARDOUS INGREDIENTS
HAZARDOUS INGREDIENTS % CAS NUMBER LD50 OF INGREDIENT
(SPECIFY SPECIES) (SPECIFY ROUTE AND DOSE)

Oil of Fennel (Natural) 100 8006-84-6 RAT ORAL: 3120 mg / kg
RABBIT DERMAL > 5 Gm / kg




SECTION 3 - PHYSICAL DATA
PHYSICAL STATE APPEARANCE ODOR ODOR THRESHOLD (ppm)
Liquid Colorless or pale yellow Odor of fennel Not Available
MELTING POINT (C) BOILING POINT (C) VOLATILITY VAPOR PRESSURE VAPOR DENSITY
5掳C 227掳C Not Available Not Available Not Available
pH SPECIFIC GRAVITY COEFF. WATER/OIL DIST. SOLUBILITY
Not Available 0.953 (Water=1) Not Available Not Available
SECTION 4 - FIRE AND EXPLOSION DATA
NO YES
FLAMMABILITY IF YES, UNDER WHAT CONDITIONS?
Flammable - Heat, Excessive heat, open flames, and other sources of ignition

MEANS OF EXTINCTION
SMALL: Use DRY chemical powder.
LARGE: Use water spray, fog or foam. Do NOT use water jet.
UPPER FLAMMABLE LIMIT (% BY VOLUME)
FLASHPOINT (C) AND METHOD LOWER FLAMMABLE LIMIT (% BY VOLUME)
62.78掳C (145掳F) Not Available Not Available
AUTOIGNITION TEMPERATURE (C) HAZARDOUS COMBUSTION PRODUCTS
Not Available (CO,CO2) Carbon oxides, Acrid smoke and fumes
SECTION 5 - REACTIVITY DATA
YES NO IF NO, UNDER WHICH CONDITIONS?
CHEMICAL STABILITY
The product is stable, Avoid excess heat, open flames, and ignition sources.

NO YES
INCOMPATIBILITY WITH OTHER SUBSTANCES IF SO, WHICH ONES?
Strong oxidizing agents, strong reducing agents

REACTIVITY, AND UNDER WHAT CONDITIONS
Not Available

HAZARDOUS DECOMPOSITION PRODUCTS
Not Available
MATERIAL SAFETY DATA SHEET
OF100X
PRODUCT IDENTIFIER
Oil of Fennel (Natural)
SECTION 6 - TOXICOLOGICAL PROPERTIES
ROUTE OF ENTRY
INGESTION
INHALATION
SKIN CONTACT SKIN ABSORPTION EYE CONTACT
EFFECTS OF ACUTE EXPOSURE TO PRODUCT
Slightly hazardous in case of skin contact (irritant), of eye contact (irritant), of inhalation, of ingestion
EFFECTS OF CHRONIC EXPOSURE TO PRODUCT
Same as above
EXPOSURE LIMITS IRRITANCY OF PRODUCT SENSITIZATION OF PRODUCT CARCINOGENICITY
Not Available Yes possible Not Available
REPRODUCTIVE TOXICITY MUTAGENICITY SYNERGISTIC PRODUCTS
TERATOGENICITY
Not Available Not Available Not Available Not Available
SECTION 7 - PREVENTATIVE MEASURE
PERSONAL PROTECTIVE EQUIPMENT
GLOVES (SPECIFY) RESPIRATOR (SPECIFY) EYE (SPECIFY)
Yes ( impervious ) Approved / Certified Vapor respirator Safety goggles, face shield
FOOTWEAR (SPECIFY) CLOTHING (SPECIFY) OTHER (SPECIFY)
No Coveralls / Lab coat Eyewash equipment nearby
ENGINEERING CONTROLS (SPECIFY eg. VENTILATION, ENCLOSED PROCESS)
Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their
respective threshold limit value. Ensure that eyewash stations and safety showers are proximal to the work-station
location.
LEAK AND SPILL PROCEDURE
Absorb with an inert material and put the spilled material in an appropriate waste disposal. Finish cleaning by spreading
water on the contaminated surface and allow to evacuate through the sanitary system.
WASTE DISPOSAL
According to local, provincial, and federal regulations.
HANDLING PROCEDURES AND EQUIPMENT
Keep away from heat. Keep away from sources of ignition. Empty containers pose a fire risk, evaporate the residue
under a fume hood. Ground all equipment containing material. Do not breathe gas/fumes/ vapor/spray.
STORAGE REQUIREMENTS
Keep container dry. Keep in a cool place. Ground all equipment containing material. Keep container tightly closed. Keep
in a cool, well-ventilated place. Combustible materials should be stored away from extreme heat and away from strong
oxidizing agents.
SPECIAL SHIPPING INFORMATION
No special requirements
SECTION 8 - FIRST AID MEASURES
SPECIFIC MEASURES
After contact with skin, wash immediately with plenty of water. Gently and thoroughly wash the
SKIN
contaminated skin with running water and non-abrasive soap. Be particularly careful to clean folds,
crevices, creases and groin. Cover the irritated skin with an emollient. If irritation persists, seek
medical attention. Wash contaminated clothing before reusing.
Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of
EYES
water for at least 15minutes. Get medical attention
If inhaled remove to fresh air. If not breathing give artificial respiration. If breathing is difficult, give
INHALATION
oxygen. Get medical attention.
INGESTION Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by
mouth to an unconscious person. Loosen tight clothing such as collar, tie, belt or waistband. Seek
immediate medical attention
IF IRRITATION PERSISTS AND IN ALL OTHER CASES, GET IMMEDIATE MEDICAL ATTENTION.
SECTION 9 - PREPARATION DATE OF M.S.D.S.
PREPARED BY (GROUP, DEPARTMENT, ETC.) PHONE NUMBER DATE:
CONTROL DEPARTMENT (604) 552 3031 October 23 2006

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
xenexlabs_com---msds.oa140x.asp 8007-70-3
xenexlabs_com---msds.ob135x.asp 8007-75-8
xenexlabs_com---msds.of100x.asp 8006-84-6
xenexlabs_com---msds.of120x.asp N/A
xenexlabs_com---msds.ol100x.asp 8008-28-0
xenexlabs_com---msds.ol110x.asp 8008-56-8
xenexlabs_com---msds.op150x.asp 8006-90-4
xenexlabs_com---msds.or140x.asp N/A
xenexlabs_com---msds.os105x.asp 8016-63-5
xenexlabs_com---msds.ot115x.asp 68647-73-4
xenexlabs_com---msds.oy160x.asp 8006-81-3
xenexlabs_com---msds.oz130x.asp 6153-56-6
xenexlabs_com---msds.oz150x.asp 131-57-7
xenexlabs_com---msds.pa113x.asp 13149-69-4 77700-02-8
xenexlabs_com---msds.pe110x.asp 8030-00-0 8006-90-4 64-17-5
xenexlabs_com---msds.pl100x.asp 25322-68-3
xenexlabs_com---msds.pl120x.asp 25322-68-3
xenexlabs_com---msds.re100x.asp 108-46-3
xenexlabs_com---msds.re110x.asp 102-29-4
xenexlabs_com---msds.re120x.asp 302-79-4
xenexlabs_com---msds.rf100x.asp 83-88-5
xenexlabs_com---msds.rh100x.asp 81-88-9
xenexlabs_com---msds.sa100x.asp 6155-57-3
xenexlabs_com---msds.sa120x.asp 69-72-7
xenexlabs_com---msds.se160x.asp N/A
xenexlabs_com---msds.sl115x.asp 7631-86-9 7732-18-5 7757-82-6
xenexlabs_com---msds.sl120x.asp 7761-88-8
xenexlabs_com---msds.so110x.asp 6131-90-4
xenexlabs_com---msds.so115x.asp 9005-38-3
xenexlabs_com---msds.so280x.asp 151-21-3
xenexlabs_com---msds.so310x.asp 7632-00-0
xenexlabs_com---msds.su050x.asp 85-83-6
xenexlabs_com---msds.sy100x.asp N/A
xenexlabs_com---msds.ta110x.asp 1401-55-4
xenexlabs_com---msds.ta120x.asp 87-69-4
xenexlabs_com---msds.ta130x.asp 107-35-7
xenexlabs_com---msds.te050x.asp 2451-01-6
xenexlabs_com---msds.te120x.asp 136-47-0
xenexlabs_com---msds.te130x.asp 64-75-5
xenexlabs_com---msds.th060x.asp 58-55-9
xenexlabs_com---msds.th100x.asp 67-03-8
xenexlabs_com---msds.tr210x.asp 64-17-5 57-55-6 2174-16-5
xenexlabs_com---msds.transderma_plo_gel.asp N/A
xenexlabs_com---msds.ur100x.asp 57-13-6
xenexlabs_com---msds.va100x.asp 8008-88-6 64-17-5
xenexlabs_com---msds.va115x.asp 27774-13-6
xenexlabs_com---msds.va125x.asp N/A
xenexlabs_com---msds.wh100x.asp 8009-03-8
xenexlabs_com---msds.wt120x.asp 64-17-5
xenexlabs_com---msds.wt130x.asp 68988-92-1 7778-77-0 7558-79-4 67-56-1

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC