INTERNATIONAL PAINT INC -- INTERSHIELD PRORECO 469, PRA460
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CGRVR
MSDS NAME: INTERSHIELD PRORECO 469, PRA460
Kit Part: Y
Responsible Party
Name: INTERNATIONAL PAINT CO INC
Address: 2270 MORRIS AVE
City: UNION NJ 07083-0386
Info Phone: 908-964-2206
Emergency Phone Number: 800-854-6813;800-424-9300(CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: INTERNATIONAL PAINT INC
Address: 6001 ANTOINE DR
City: HOUSTON TX 77091
Phone: 800-589-1267/800-854-6813
=======================================================
Ingredients
=======================================================
Cas: 1344-28-1
RTECS #: BD1200000
Name: ALUMINUM OXIDE (2:3) (SARA 313)
% Wt: 25-50
OSHA PEL: 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
------------------------------
Cas: 110-43-0
RTECS #: MJ5075000
Name: 2-HEPTANONE; (METHYL N-AMYL KETONE)
% Wt: 10-25
OSHA PEL: 100 PPM
ACGIH TLV: 50 PPM
------------------------------
Cas: 13463-67-7
RTECS #: XR2275000
Name: TITANIUM OXIDE; (TITANIUM DIOXIDE)
% Wt: 1-10
OSHA PEL: 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
------------------------------
Cas: 108-94-1
RTECS #: GW1050000
Name: CYCLOHEXANONE (CERCLA)
% Wt: 1-10
OSHA PEL: 50 PPM, S
ACGIH TLV: 25 PPM, S
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 60676-86-0
RTECS #: VV7328000
Name: SILICA, CRYSTALLINE - FUSED; (SILICA, AMORPHOUS)
% Wt: 1-10
OSHA PEL: N/K (FP N)
ACGIH TLV: 0.1 MG/M3 RDUST
------------------------------
Cas: 25322-69-4
RTECS #: TR5250000
Name: POLYPROPYLENE GLYCOL
% Wt: 1-10
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 65308-91-0
RTECS #: 9999999ZZ
Name: EXTENDED POLYETHER POLYOL
% Wt: 1-10
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 107-15-3
RTECS #: KH8575000
Name: 1,2-ETHANEDIAMINE (SARA 302) (CERCLA)
OSHA PEL: 10 PPM
ACGIH TLV: 10 PPM, S
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Name: EYE PROT: & FULL LENGTH FACESHIELD (FP N).
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: YES
IARC: YES
OSHA: NO
Effects of Exposure: INHALATION: VAPOR HARMFUL. MAY AFFECT THE BRAIN OR NERVOUS
SYSTEM CAUSING DIZZINESS, HEADACHE OR NAUSEA. CAUSES NOSE AND THROAT
IRRITATION. CAUSES LUNG IRRITATION. EYE CONTACT: CAUSES EYE BURNS. SKIN
CONTACT: CAUSES SKIN BURNS. CAN BE ABSORBED THRU SKIN. MAY CAUSE ORGAN
DAMAGE. INGESTION: MAY BE (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: SILICA, CRYSTALLINE-FUSED: IARC MONO, VOL 68,
1997:GROUP 1. NTP 7TH ANNUAL REPORT ON CARCINS, 1994:ANTIC TO BE CARCIN.
Signs And Symptions Of Overexposure: HLTH HAZ: FATAL IF SWALLOWED AND MAY CAUSE
ORGAN DAMAGE. NOTICE: REPORTS HAVE ASSOCIATED REPEATED AND PROLONGED
OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND NERVOUS SYSTEM
DAMAGE. IN TENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND INHALING THE
CONTENTS MAY BE HARMFUL OR FATAL.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: IN ALL CASES OF DOUBT OR WHEN SYMPS PERSIST, SEEK MED ATTN. NEVER
GIVE ANYTHING BY MOUTH TO UNCON PERSON. INHAL: REMOVE TO FRESH AIR. IF
DISCOMFORT IS PRESENT OR BRTHG ABSENT GET MED ATTN IMMED. EYES: FLUSH IMMED
W/PLENTY OF WATER FOR AT LEAST 15 MIN UNTIL IRRIT SUBSIDES. IF IRRIT
PERSISTS, GET MED ATTN. SKIN: FLUSH W/LG AMTS OF WATER. USE SOAP IF AVAIL.
REMOVE SEVERELY CONTAM CLTHG (INCL (SUPDAT)
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CONTAIN SPILLED LIQUID WITH SAND OR EARTH. DO NOT USE
COMBUSTIBLE MATERIALS SUCH AS SAWDUST. ABSORB SPILL WITH AN INERT MATERIAL
(EG, DRY SAND OR EARTH), THEN PLACE IN A CHEMICAL WASTE CONTAINER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS. DO NOT INCINERATE UNOPENED CONTAINERS.
Handling And Storage Precautions: KEEP CONTAINER CLOSED. LOOSEN CLOSURE
CAUTIOUSLY BEFORE OPENING. STORE IN A COOL, WELL VENTD PLACE AWAY FROM
INCOMPATIBLE MATERIALS.
Other Precautions: KEEP AWAY FROM HEAT, SPARKS & FLAMES. PROTECT MATL FROM
DIRECT SUNLIGHT. GROUND & BOND CONTAINERS WHEN TRANSFERRING MATLS. EMPTY
CONTAINERS MAY RETAIN HAZARDOUS PROPERTIES. FOLLOW ALL MSDS/LABEL WARNI NGS,
EVEN AFTER CONTAINER IS EMPTIED.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: 115F,46C
Lower Limits: 1.1%
Extinguishing Media: FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N).
Unusual Fire/Explosion Hazard: ISOLATE FROM HEAT, SPARKS, ELEC EQUIP & OPEN
FLAME. CLSD CNTNRS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. IN ABSENCE OF
ELECTRICITY, WATER SPRAY (FOG (SUPDAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH APPROVED RESPIRATOR IN ACCORDANCE WITH 29 CFR
1910.134 TO REMOVE PARTICULATES (AND VAPORS IF THERE IS OVEREXPOSURE TO
VAPORS GENERATED DURING THE PROCESSING OF THIS PRODUCT).
Ventilation: PROVIDE SUFFICIENT VENT, IN VOL & PATTERN TO: A) KEEP TLV OF
HAZ INGREDS BELOW SPECIFIED LIMS; B) REMOVE VOLATS (SUPDAT)
Protective Gloves: CHEMICAL RESISTANT GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). AS
NEEDED, USE BODY PROTECTION TO AVOID CONTACT WITH PRODUCT.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: EXPLO HAZ:NOZZ PREF) MAY BE USED TO COOL
CNTNRS. DECOMP & COMBUST PRODS MAY BE TOX. FIRST AID PROC: SHOES) &
WASH BEFORE REUSE. IF IRRIT PERSISTS, GET MED ATTN. INGEST: DO NOT INDUCE
VOMIT. KEEP AT RE ST. GET PROMPT MED ATTN. VENT: PRDCED DURING CURE &
DECOMP PRODS PRDCED DURING WELDING/CUTTING ON SURFS COATED W/PROD.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 305F,152C
Vapor Density: HVR/AIR
Spec Gravity: 1.819
Evaporation Rate & Reference: SLOWER/ETHER
Appearance and Odor: LIQUID.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products: MAY PRODUCE HAZARDOUS FUMES WHEN HEATED TO
DECOMP AS IN WELDING. FUMES MAY PRODUCE CARBON DIOXIDE & CARBON MONOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: INTERSHIELD PRORECO 469, PRA460
Company: INTERNATIONAL PAINT INC
Street: 6001 ANTOINE DR
City: HOUSTON TX
Zipcode: 77091
Health Emergency Phone: 800-854-6813;800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 03/25/1998
Status Code: C
Label Date: 03/25/1998
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Severe
Contact Hazard: Severe
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE: INHALATION: VAPOR HARMFUL. MAY
AFFECT THE BRAIN OR NERVOUS SYSTEM CAUSING DIZZINESS, HEADACHE OR NAUSEA.
CAUSES NOSE, THROAT AND LUNG IRRITATION. EYE CONTACT: CAUSES EYE BURNS. SKI N
CONTACT: CAUSES SKIN BURNS. CAN BE ABSORBED THROUGH SKIN. MAY CAUSE ORGAN
DAMAGE. INGESTION: MAY BE FATAL IF SWALLOWED AND MAY CAUSE ORGAN DAMAGE.
CHRONIC: CANCER HAZARD. CONTAINS SILICA, CRYSTALLIN E-FUSED WHICH IS LISTED
AS A HUMAN LUNG CARCINOGEN (FP N). OVEREXPOSURE TO SOLVENTS IS ASSOCIATED
WITH PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE MAY BE
HARMFUL OR FATAL.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.