LORAL HYCOR INC -- 6133060, MK 214 MOD 0 RF SEDUCTION, (SUPDAT)
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CGRWF
MSDS NAME: 6133060, MK 214 MOD 0 RF SEDUCTION, (SUPDAT)
Responsible Party
Name: LORAL HYCOR INC
Address: 10 GILL ST
City: WOBURN MA 01801
Info Phone: 617-935-5950
Emergency Phone Number: 617-935-5950
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LORAL HYCOR INC
Address: 10 GILL ST
City: WOBURN MA 01801
Phone: 617-935-5950
=======================================================
Ingredients
=======================================================
Name: EXPLOSIVE INGREDIENTS
% Wt: 0.6
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Name: BULLSEYE PROPELLANT HERCULES (36 EXP. WT.)
% Wt: 36
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Name: M30 PROPELLANT (50 EXP. WT.)
% Wt: 50
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Name: SKNO3 PELLETS (4 EXP. WT.)
% Wt: 4
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 78-11-5
RTECS #: RZ2620000
Name: PENTAERYTHRITOL, TETRANITRATE (8 EXP. WT.)
% Wt: 8
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 121-82-4
RTECS #: XY9450000
Name: S-TRIAZINE, HEXAHYDRO-1,3,5-TRINITRO-; (CYCLONITE) (1 EXP. WT.)
% Wt: 1
OSHA PEL: S, 1.5 MG/M3
ACGIH TLV: S, 1.5 MG/M3
------------------------------
Cas: 13424-46-9
RTECS #: OF8650000
Name: LEAD AZIDE (1 EXP. WT.)
% Wt: 1
OSHA PEL: RULE IN PROCESS
ACGIH TLV: 0.15 MG PB/M3
------------------------------
Name: ALUMINIZED FIBERGLASS
% Wt: 49
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 25038-81-7
Name: POLYIMIDE POLYMER; (KAPTON)
% Wt: 9
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 7439-92-1
RTECS #: OF7525000
Name: LEAD (SARA 313) (CERCLA)
% Wt: 6
OSHA PEL: SEE 1910.1025
ACGIH TLV: 0.15MG/M3 DUST
EPA Rpt Qty: 1 LB
DOT Rpt Qty: 1 LB
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: PRIMARY ROUTE OF ENTRY: NONE-EXCEPT WHEN ITEM IS
FUNCTIONED, THEN INHALATION OF PRODUCTS OF COMBUSTION. LEAD APPEARS ON THE
NAVY LISTING OF OCCUP CHEM REPROD HAZARDS. SEEK CONSULTATION FROM APPROP HLT
H PROFESSIONALS CONCERNING LATEST HAZARD LIST INFO & SAFE HNDLG &
EXPOS INFO (FP N).
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: TREAT BURNS & LACERATIONS BY CLEANING & APPLYING STERILE
BANDAGES. CALL EMER MED HELP IMMED. INGEST: CALL MED IMMEDIATELY (FP N).
INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE OXYG/ARTF RESP) (FP N) .
EYES: IMMED FLUSH W/POTABLE WATER FOR@ LST 15 MINS, SEEK ASSISTANCE FROM MD
(FP N). SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD (FP N).
=======================================================
Handling and Disposal
=======================================================
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. CONTACT MANUFACTURER IF THERE ARE ANY DISPOSAL
QUESTIONS.
Handling And Storage Precautions: KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAMES.
ELIMINATE STATIC DISCHARGE SOURCES.
Other Precautions: ACCESS TO THIS ITEM SHOULD BE LIMITED TO AUTHORIZED
PERSONNEL TRAINED IN THE HANDLING OF EXPLOSIVES AND PURCTECHNIC DEVICES.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: WATER, CARBON DIOXIDE OR FOAM.
Fire Fighting Procedures: NIOSH APPRVD SCBA & FULL PROT EQUIP (FP N).
EXPLOSIVE 1.45. DO NOT FIGHT FIRES. EVACUATE PERS FROM AREA, ESPECIALLY IF LG
QTYS OF CARTRIDGES ARE (SUPDAT)
Unusual Fire/Explosion Hazard: PRODS OF REACTION ARE TOXIC. DO NOT
INHALE/INGEST. POSSIBLE EXPLOSIVE SHOCK WAVE AND SHRAPNAL.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN (FP N).
Ventilation: MECHANICAL VENTILATION ONLY REQUIRED WHEN FUNCTIONING ITEM IN
CONFINED AREAS.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N).
GROUNDING STRAPS AND/OR CONDUCTIVE FOOTWARE.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: MFR TRADE NAME/PART NO: CARTRIDGE DRAWING. FIRE
FIGHT PROC: INVOLVED. MATL WILL BURN RAPIDILY PRDCG HIGH TEMP FLAMES, HOT
HIGH VELOCITY GASES & PARTICULATE MATTER. EXPLO RXN MAY OCCUR, WHICH
WOULD PRD CE METAL SHRAPNEL.
=======================================================
Physical/Chemical Properties
=======================================================
Solubility in Water: INSOLUBLE
Appearance and Odor: NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume: NEGLIG
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: STORE IN AN APPROVED MAGAZINE FOR EXPLOSIVE 1.48
AT AMBIENT TEMPERATURE AND HUMIDITY.
Materials To Avoid: CHECK EXPLOSIVE STORAGE INCOMPATIBILITY.
Hazardous Decomposition Products: PRODUCTS OF REACTION ARE TOXIC. DO NOT INHALE
OR INGEST. POSSIBLE EXPLOSIVE SHOCK WAVE AND SHRAPNAL.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 6133060, MK 214 MOD 0 RF SEDUCTION, (SUPDAT)
Company: LORAL HYCOR INC
Street: 10 GILL ST
City: WOBURN MA
Zipcode: 01801
Health Emergency Phone: 617-935-5950
Label Required IND: Y
Date Of Label Review: 03/23/1998
Status Code: C
Label Date: 03/23/1998
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: Severe
Hazard And Precautions: EXPLOSIVE! EXPLOSIVE SHOCK WAVE AND SHRAPNEL. PRODUCTS
OF REACTION ARE TOXIC. ACUTE: INHALATION OF PRODUCTS OF COMBUSTION. CHRONIC:
LEAD APPEARS ON NAVY OCCUPATIONAL CHEMICAL REPRODUCTIVE HAZARDS LIST (FP N).
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.