HEXAGON CH -- HEXAFLOC KSP
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CGSDK
MSDS NAME: HEXAFLOC KSP
Responsible Party
Name: HEXAGON CH
Box: 23163
City: LOUISVILLE KY 40223
Info Phone: 502-429-8990
Emergency Phone Number: 502-228-4001
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: HEXAGON CHEMICAL CO INC
Address: 3600 CHAMBERLAIN LN
Box: 23163
City: LOUISVILLE KY 40241-1988
Phone: 502-429-8990 / FAX 502-429-8911
Name: HEXAGON TECHNOLOGIES, INC.
Address: UNKNOWN
Box: 23163
City: LOUISVILLE KY 40223
Phone: 502-429-8990/502-228-4001
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYE CONTACT: IRRITATING AND WILL INJURE EYE TISSUE IF NOT
WASHED OFF PROMPTLY AND THOROUGHLY. SKIN CONTACT: IRRITATING. LOW ORDER OF
TOXICITY. INHALATION: IRRITATING TO EYES AND RESPIRATORY TRACT IN H IGH
CONCENTRATIONS. INGESTION: SMALL AMOUNTS OF LIQUID ASPIRATED INTO RESPIRATORY
SYSTEM DURING (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ: INGESTION OR FROM VOMITING MAY
CAUSE BRONCHIOPNEUMONIA OR PULMONARY EDEMA.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYES: IMMED FLUSH EYES W/LARGE AMTS OF WATER FOR AT LEAST 15 MIN.
SEEK MED ATTN. SKIN: FLUSH W/LARGE AMTS OF WARM WATER; USE SOAP IF AVAIL.
REMOVE GROSSLY CONTAM CLTHG, INCLUDING SHOES & LAUNDER BEFOR E REUSE.
INHAL: USING PROPER NIOSH APPRVD RESP PROT, IMMED REMOVE AFFECTED VICTIM FROM
EXPOSURE. ADMIN ARTF RESP IF BRTHG IS STOPPED. KEEP AT REST. CALL FOR PROMPT
MED ATTN. INGEST: IF
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: LAND SPILL: FOR SM SPILLS IN WORK AREAS, IMPLEMENT
CLEANUP PROCS USING DRY ABSORBS. FOR LARGE SPILLS, IMPLEMENT CLEANUP PROCS
& IF IN PUBLIC AREA, KEEP PUBLIC AWAY & ADVISE AUTHS. PREVENT LIQ
FROM ENT ERING, SEWERS, WATERCOURSES OR LOW AREAS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: CONSULT AN EXPERT ON DISPOSAL OF RECOVERED MATERIAL AND
ENSURE CONFORMITY TO LOCAL, STATE AND FEDERAL DISPOSAL REGULATIONS.
Handling And Storage Precautions: PROTECT FROM FREEZING. IF FROZEN, LET SIT IN
A WARM AREA.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: SCC
Flash Point Text: >300F,>149C
Extinguishing Media: USE FOAM, DRY CHEMICAL OR WATER SPRAY TO EXTINGUISH FIRE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N). USE WATER TO COOL HOT SURFACES AND TO PROCTECT PERSONNEL.
Unusual Fire/Explosion Hazard: LOW HAZ-LIQ CAN BURN UPON HEATING TO TEMPS
>FL PT. "EMPTY" CNTNRS CAN RETAIN PROD RESIDUE (LIQ &/OR VAP) &
CAN BE DANGEROUS. DO NOT PRESSURIZE, CUT, (SUPDAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: WHERE CONCENTRATIONS IN AIR MAY EXCEED THE LIMITS GIVEN
ABOVE, NIOSH APPROVED RESPIRATORS MAY BE NECESSARY TO PREVENT OVEREXPOSURE.
Ventilation: USE OF MECH DILUTION VENT IS RECOM WHENEVER PROD IS USED IN
CONFINED SPACE, IS HEATED ABOVE AMBIENT TEMPS OR AGITATED.
Protective Gloves: CHEMICAL RESISTANT GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). FOR
OPEN SYSTEMS WHERE CONTACT IS LIKELY, WEAR LONG SLEEVES.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). PH, NEAT: 4-6. EXPLO HAZ: WELD, BRAZE, SOLDER,
DRILL, GRIND/EXPOSE SUCH CNTNRS TO HEAT, FLAME, SPKS, STATIC ELEC/OTHER
SOURCES O F IGNIT; THEY MAY EXPLODE & CAUSE INJURY/DEATH. EMPTY DRUMS
SHOULD BE COMPLETELY DRAINED, PROPERLY BUNGED &
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 212F,100C
M.P/F.P Text: >10F,>-12C
Vapor Pres: <10 @ 77F
Spec Gravity: 1.26-1.44(FP N)
PH: SUPDAT
Solubility in Water: SOLUBLE
Appearance and Odor: DARK VISCOUS LIQUID.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: AVOID TEMPERATURES ABOVE 130F. AVOID TEMPERATURES
BELOW 32F.
Materials To Avoid: STRONG ACIDS, ALKALIS OR OXIDIZING AGENTS MAY DEGRADE
PRODUCT.
Hazardous Decomposition Products: NONE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: HEXAFLOC KSP
Assigned IND: Y
Company: HEXAGON TECHNOLOGIES, INC.
Street: UNKNOWN
PO Box: 23163
City: LOUISVILLE KY
Zipcode: 40223
Health Emergency Phone: 502-228-4001
Label Required IND: Y
Date Of Label Review: 03/17/1998
Status Code: C
Label Date: 03/17/1998
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: EYE CONTACT: IRRITATING AND WILL INJURE EYE
TISSUE IF NOT WASHED OFF PROMPTLY AND THOROUGHLY. SKIN CONTACT: IRRITATING.
INHALATION: IRRITATING TO EYES AND RESPIRATORY TRACT IN HIGH CONCENTRATIO NS.
INGESTION: SMALL AMOUNTS OF LIQUID ASPIRATED INTO RESPIRATORY SYSTEM DURING
INGESTION OR FROM VOMITING MAY CAUSE BRONCHIOPNEUMONIA OR PULMONARY EDEMA.
CHRONIC: NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.