===================== Product Identification =====================
MSDS NAME:ACCU-PEN #2
NIIN:00-782-2740
Kit Part:Y
MSDS Number: BFPPJ
=== Responsible Party ===
Company:PARKER DIVISION-OXY METAL INDUSTRIES CORP
Address:32100 STEPHENSON HWY
City:MADISON HEIGHTS
State:MI
ZIP:48071-1003
Country:US
Emergency Phone Num:NONE
CAGE:HO255
=== Contractor Identification ===
Company:OXY METAL INDUSTRIES CORP, PARKER CO
Address:32100 STEPHENSON HWY
Box:City:MADISON HEIGHTS
State:MI
ZIP:48071-1003
Country:US
CAGE:45738
Company:PARKER DIVISION-HOOKER CHEMICALS & PLASTICS CORP
Address:32100 STEPHENSON HWY
Box:City:MADISON HEIGHTS
State:MI
ZIP:48071-1003
Country:US
CAGE:HO255
============= Composition/Information on Ingredients =============
Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 66%
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1
Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: 9%
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192
Name:DICHLORODIFLUOROMETHANE (SARA III)
CAS:75-71-8
RTECS #:PA8200000
Fraction by Wt: 25%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1
===================== Hazards Identification =====================
Effects of Overexposure:MILD EYE IRRITATION.ANESTHESIA MAY OCCUR IN
RANGE OF 500 TO 1000 PPM
======================= First Aid Measures =======================
First Aid:EYES/SKIN-FLUSH WITH WATER.GET MEDICAL ATTENTION FOR
INJURIES.SWALLOWED-INDUCE VOMITING,CALL PHYSICIAN.INHALATION-REMOVE
TO FRESH AIR.IF BREATHING STOPS,GIVE ARTIFICIAL RESPIRATION.GET
MEDICAL HELP.
===================== Fire Fighting Measures =====================
Flash Point:NONE T.C.C.
Extinguishing Media:WATER FOG
Fire Fighting Procedures:USE SELF CONTAINED BREATHING GEAR
Unusual Fire/Explosion Hazard:ARE AEROSOL CANS-MAY EXPLODE WHEN HEATED
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL LEAKS-MOP UP OR SOAK UP.IMMEDIATELY MOVE
OUTSIDE.LARGE SPILLS-EVACUATE AREA.CONTAIN LIQUID.TRANSFER TO
CLOSED METAL CONTAINERS.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN CHEMICAL STORAGE AREA.HANDLE
WITH CARE.AVOID BREATHING VAPORS.DO NOT PUNCTURE OR INCINERATE
AEROSOL CONTAINERS.
Other Precautions:FOR DOCTOR-OVER EXPOSURE TO CHLORINATED SOLVENTS IF
ACCOMPANIED BY ANOXIA MAY TEMPORARILY INCREASE CARDIAC IRRITABILITY
MANTAIN ADEQUATE OXYGENATION UNTIL RECOVERY.SEE SUPPLEMENTAL DATA
============= Exposure Controls/Personal Protection =============
Respiratory Protection:SELF CONTAINED AS NEEDED TO LIMIT CONCENTRATION
TO TLV.
Ventilation:LOCAL RECOMMENDED
Protective Gloves:NOT NEEDED
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NO SPECIAL PROTECTIVE CLOTHING NEEDED
Supplemental Safety and Health
AVOID SYMPATOMIMETIC AMINES,SUCH AS EPINEPHRINE,WHICH MAY PRECIPITATE
ARRHYTHMIAS.
================== Physical/Chemical Properties ==================
HCC:V2
Boiling Pt:=73.9C, 165.F
Vapor Pres:100
Vapor Density:4.55
Spec Gravity:1.3
Solubility in Water:VERY SLIGHT
Appearance and Odor:YELLOW LIQUID
Percent Volatiles by Volume:91
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
WATER-SLOW HYDROLYSIS PRODUCES CORROSIVE ACID
Stability Condition to Avoid:OPEN FLAMES OR HIGH TEMPERATURE SOURCE
Hazardous Decomposition Products:HYDROGEN CHLORIDE,PHOSGENE & CHLORINE
==================== Disposal Considerations ====================
Waste Disposal Methods:SEND SOLVENT TO RECLAIMER.SEE ALSO MANUFACTURING
CHEMISTS ASSOCIATION SAFETY DATA SHEET SD-90.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|