===================== Product Identification =====================
MSDS NAME:ENAMEL,ALKYD,LUST YELLOW 33538,ID 741310
NIIN:00-297-0570
MSDS Number: BHMLC
=== Responsible Party ===
Company:PRATT & LAMBERT, INC.
Address:INDUSTRIAL COATINGS DIVISION
Box:2153
City:WICHITA
State:KS
ZIP:67201
Country:US
Info Phone Num:(316) 733-1361
Emergency Phone Num:(316) 733-1361
Preparer's Name:W.A. ELLINSON
CAGE:FO127
=== Contractor Identification ===
Company:PRATT & LAMBERT, INC/BUFFALO, NY 14240
Box:22
CAGE:FO127
Company:PRATT AND LAMBERT INC
Address:Box:6027
City:CLEVELAND
State:OH
ZIP:44101-1027
Country:US
Phone:216-566-2902
CAGE:61196
============= Composition/Information on Ingredients =============
Name:MINERAL SPIRITS
(VAPOR PRESSURE 2 MM HG @ 20C)
CAS:8032-32-4
OSHA PEL:500PPM 2950 MG/CU M
ACGIH TLV:100 PPM 525 MG/CU M
Name:XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:LEAD CHROMATE (OSHA PEL FOR LEAD FROM 29CFR
1910.1025),(CRO3 CEILING 0.1 MG/M3)
CAS:7758-97-6
RTECS #:GB2975000
OSHA PEL:0.05 MG/M3 (PB)
ACGIH TLV:0.05MG/M3(CR)A2;8990
Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293
Name:SILICA, CRYSTALLINE - CRISTOBALITE
CAS:14464-46-1
RTECS #:VV7325000
OSHA PEL:SEE TABLE Z3
ACGIH TLV:0.05 MG/M3 RDUST9293
Name:SILICA, CRYSTALLINE - FUSED
CAS:60676-86-0
RTECS #:VV7328000
OSHA PEL:SEE TABLE Z3
ACGIH TLV:0.1 MG/M3 RDUST;9293
Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192
Name:LEAD (SARA III)
CAS:7439-92-1
RTECS #:OF7525000
OSHA PEL:0.05 MG/M3;1910.1025
ACGIH TLV:0.15 MG/M3;DUST 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:VOC. ORGANIC CMPD 3.7 LB/GL LESS WATER & NPRS* 444 G/L LESS
WATER VOC 8.4 LB/GAL SOLIDS 1008 G/L SOLIDS CALCULATED.
RTECS #:9999999VO
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:REPORTS HAVE ASSOCIATED
PROLONGED/REPEATED OCCUPATIONAL OVEREXPOSURE TO SOLVENTSWITH
PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY
DELIBERTLY CONCENTRATING & INHALING THE CONTENTS MA Y BE HARMFUL
OR FATAL.
Explanation of Carcinogenicity:LEAD CHROMATE HAS BEEN LISTED AS
POTENTIAL CARCINOGEN TITANIUM DIOXIDE IS NOT LISTED AS A
CARCINOGEN
Effects of Overexposure:SWALLOWING CAN CAUSE GASTROINTESTINAL
IRRITATION,NAUSEA,VOMITING, & DIARRHEA. INHALATION MAY CAUSE
IRRITATION OF THE NOSE & THROAT, & ACUTE NERVOUS SYSTEM
DEPRESSION. CHARACTERIZED BY HEADACHE,DI
ZZINESS,CONFUSION,NAUSEA,UNCONSCIOUSNESSAND EVEN ASPHYXIATION.
EYE/SKIN: EYE IRRITATION, SKIN DEFATTING/IRRITATION.
Medical Cond Aggravated by Exposure:ASPIRATION OF MATERIAL INTO THE
LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.
======================= First Aid Measures =======================
First Aid:IF SWALLOWED, INDUCE VOMITING IMMEDIATELY BY GIVING TWO
GLASSES OF WATER & STICKFINGER DOWN THROAT. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON. REMOVE TO FRESH AIR
IMMEDIATELY. IF BREA THING HAS STOPPED, GIVE ARTIFICIAL RESPIRTION.
KEEP WARM & QUIET. FLUSH EYES W/LARGE AMOUNTS OF WATER FOR 15MINS.
SKIN WASH AFFECTED AREA W/SOAP & WATER. GET MEDICAL ATTENTION IF
IRRITATION PRESISTS.
===================== Fire Fighting Measures =====================
Flash Point:80F/26.67C
Extinguishing Media:USE NFPA CLASS B FIRE EXTINGUISHERS DESIGNED TO
EXTINGUISH FLAMMABLE LIQ FIRES. POLYMER FOAM IS PREFERRED FOR LG
FIRES.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS. WATER
MAYBE INEFFECTIVE, MAYBE USED TO COOL EXPOSED CONTAINERS. IF WATER
IS USED, FOG NOZZLEES ARE PREFERABLE.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
FROM HEAT,ELECTRICAL EQUIPMENT,SPARKS & FLAME. CLOSED CONTAINERS
MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT.
================== Accidental Release Measures ==================
Spill Release Procedures:KEEP SPECTATORS AWAY. ELIMINATE ALL IGNITION
SOURCES (FLAMES,HOT SURFACES,ELECTRICAL,STATIC, ORSPARKS). DIKE
& CONTAIN SPILL W/INERT MATERIAL (SAND, EARTH, ETC.). TRANSFER
LIQUIDS TO COVERED METAL CONTAINERS FOR RECOVERY/DISPOSAL
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 120F. CLOSE
CONTAINER AFTER EACH USE. DO NOT TAKE INTERNALLY. DO NOT BREATH
SANDING DUST.
Other Precautions:EMPTY CONTAINERS MUST NOT BE WASHED AND REUSED FOR
ANY PURPOSE. DO NOT WELD, BRAZE OR CUT ON EMPTY CONTAINER. NEVER
USE PRESSURE TO EMPTY. DRUM IS NOT A PRESSURE VESSEL.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHEN SPRAYING OUTDOORS,IN OPEN, OR WELL
VENTILATED AREAS,USE NIOSH APPROVED MECHANICAL FILTER
RESPIRATOR TO REMOVE OVERSPRAY. IN CONFINED AREAS USE A NIOSH
APPROVED AIR SUPPLIED RESPIRATOR.
Ventilation:PROVIDE GENERAL DILUTION/LOCAL EXHAUST VENT IN SUFFICIENT
VOLUME.
Protective Gloves:SOLVENT IMPERMEABLE GLOVES
Eye Protection:SAFETY SPECTACLES W/SIDE SHIELDS
Other Protective Equipment:WEAR FACE SHIELD AS NECESSARY WHEN SPRAYING
Work Hygienic Practices:NONE
Supplemental Safety and Health
NK
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:244F - 395F
Vapor Density:> AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:56
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACID OR ALKALINE MATERIALS
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING OR CUTTING. WILL PRODUCE SMOKE, CARBON MONOXIDE AND CARBON
DIOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDNCE W/FEDERAL,STATE,LOCAL LAWS.
INCINERATE ONLY IN PERMITTED FACILITY. DONOT IN CINERATE CLOSED
CONTAINERS. CONTAMINATED ABSORBANTMAY BE DISPOSED IN A HAZARDOUS
WASTE LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|