GFS CHEMICALS, INC.
P.O. Box 245 Powell, OH 43065
740-881-5501(Tel.) 740-881-5989(Fax)
1-800-424-9300(Chemtrec 24Hr. Info.)
MATERIAL SAFETY DATA SHEET
3126
cis-2,3-EPOXYBUTANE
CHEMICAL NAME & SYNONYMS DOT CLASS SARA TITLE 313
cis-2,3-Epoxybutane 3/II No
cis-2,3-Dimethyloxirane; cis-2-Butene Oxide TSCA listed - No
FORMULA REPORTABLE QUANTITY F.W. CAS#
CH 3(HCOCH)CH 3 N/A 72.11 1758-33-4
PHYSICAL DATA
Density 0.826; Boiling point 60-61掳C; Melting point -80掳C.
APPEARANCE & ODOR
Clear, colorless to light yellow liquid.
REACTIVITY & CONDITIONS TO AVOID
Stable. Incompatible with oxidizing materials, heat and sources of ignition. Will decompose on
exposure to moist air or water.
FIRE HAZARDS
Flammable liquid, will emit toxic fumes of carbon monoxide and carbon dioxide. Firefighters wear
SCBA.
EXTINGUISHER FLASHPOINT LEL UEL
CO 2, ABC dry powder, foam, water spray or fog. -26掳C Not known
HEALTH HAZARDS
The chemical, physical and toxicological properties of this product have not been fully
investigated. It is supplied for use in research and development only and must be used by or
under the supervision of a technically qualified individual. May be harmful by inhalation,
ingestion or skin absorption. May be irritating to skin, eyes and mucous membranes. LD/TD no
data. OSHA PEL/ACGIH TLV not established. Mutagenic data. While not a listed carcinogen, it may
be carcinogenic.
FIRST AID
Remove contaminated clothing immediately and launder before reuse. Discard contaminated shoes.
For eyes, flush with plenty of water for at least fifteen minutes. Seek medical attention
immediately. For skin, wash thoroughly with soap and water, while removing clothing. Seek
medical attention. For inhalation, remove to fresh air. If not breathing give mouth to mouth
resuscitation. If breathing is difficult, give oxygen. Seek medical attention at once. For
ingestion, seek medical attention at once.
SPECIAL PRECAUTIONS
Wear goggles, rubber gloves, protective clothing. Use only with adequate ventilation and/or
suitable respiratory protection. Avoid all contact. Store cylinder in a refrigerator, protected
from air and moisture.
SPILLS & LEAKS
Remove ignition sources. Ventilate area. Equip personnel with respirator. Take up spill in
absorbent and dispose to incinerator or other suitable hazardous waste.
CATALOG # PREPARED BY DATE
3126 MDM November 6, 2006
Full Warranty and Limitations Statement should be reviewed at www.gfschemicals.com/terms.asp.
|