GFS CHEMICALS, INC.
P.O. Box 245 Powell, OH 43065
740-881-5501(Tel.) 740-881-5989(Fax)
1-800-424-9300(Chemtrec 24Hr. Info.)
MATERIAL SAFETY DATA SHEET
3191
trans-3-HEXEN-1-OL
CHEMICAL NAME & SYNONYMS DOT CLASS SARA TITLE 313
trans-3-Hexen-1-ol 3/III No
Farchan Prod. No. 157795 TSCA listed - Yes
FORMULA REPORTABLE QUANTITY F.W. CAS#
CH 3CH 2CH=CHCH 2CH 2OH N/A 100.16 928-97-2
PHYSICAL DATA
Boiling point 61-2掳C @ 12 mm Hg. Density 0.817. Index of refraction 1.4374.
APPEARANCE & ODOR
Clear, colorless to yellow liquid.
REACTIVITY & CONDITIONS TO AVOID
Stable. Hazardous polymerization will not occur. Incompatible with strong acids and oxidizing
agents.
FIRE HAZARDS
Flammable liquid, will emit toxic fumes of carbon monoxide, carbon dioxide. Firefighters wear
SCBA. NFPA # 0-2-0.
EXTINGUISHER FLASHPOINT LEL UEL
CO 2, ABC dry powder, foam, water spray or fog. 58掳C Not known
HEALTH HAZARDS
May be irritating to skin, eyes and mucous membranes. May be harmful if swallowed, inhaled or
absorbed through skin. The HEALTH RISKS of this product HAVE NOT BEEN FULLY DETERMINED. Avoid
contact with skin and eyes. Avoid breathing vapor. LD/TD information not found for this isomer.
LD 50 (oral-rat) 4700 mg (cis- isomer)/kg. OSHA PEL/ACGIH TLV not established. This material is
not a listed carcinogen. It DOES NOT indicate absence of carcinogenicity.
FIRST AID
Remove contaminated clothing immediately and launder before reuse. Discard contaminated shoes.
For eyes, flush with plenty of water for at least fifteen minutes. Seek medical attention
immediately. For skin, wash thoroughly with soap and water, while removing clothing. Seek
medical attention if rash should occur. For inhalation, remove to fresh air. If not breathing
give mouth to mouth resuscitation. If breathing is difficult, give oxygen. Seek medical
attention at once. If ingested, do NOT induce vomiting. If conscious, give 2-4 cups of milk
or water. Seek medical attention at once.
SPECIAL PRECAUTIONS
Goggles, rubber gloves, protective clothing are required. Use only with adequate ventilation
and/or suitable respiratory protection. Avoid all contact.
SPILLS & LEAKS
Ventilate area. Equip personnel with SCBA and full protective clothing. Take up spill in
absorbent and dispose to incinerator or other suitable hazardous waste. Wash spill area
thoroughly with water after absorbent is picked up.
CATALOG # PREPARED BY DATE
3191 MDM February 18, 2004
|