Toxicity: Eye irritant.
Estimated oral LD50 more than 5000mg/kg
Estimated dermal LD50 more than 2000mg/kg
Primary Routes of Entry: None known
Signs and symptoms
of Exposure: May cause dermatitis on prolonged contact in sen-
sitive individuals.
Existing Conditions
Aggravated by Exposure: None known
Literature Referenced Carcinogen
Ingredients Target Organ and Other Health Effects NTP IARC OSHA
Polyglycol dimethacrylate ALG IRR NO NO NO
Bisphenol A fumarate resin ALG IRR NO NO NO
SACCHARIN No Data YES 2B NO
CUMENE HYDROPEROXIDE ALG CNS COR IRR MUT NO NO NO
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 02 of 04
Product Name: 271(TM) High Strength Threadlocker Red
Item No.: 27100
3. HAZARDS IDENTIFICATION (continued)
N,N-Dialkyltoluidines No Data NO NO NO
-------------------------------------------------------------------------------
Abbreviations
2B Possibly carcinogenic to humans ALG Allergen
CNS Central nervous system COR Corrosive
IRR Irritant MUT Mutagen
4. FIRST AID MEASURES
Ingestion: Do not induce vomiting. Keep individual calm.
Obtain medical attention.
Inhalation: Does not apply
Skin Contact: Flush with water.
Eye Contact: Flush at least 15 minutes with water. Obtain
medical attention.
5. FIRE FIGHTING MEASURES
Flash Point: More than 200掳F Method: Tag Closed Cup
Recommended
Extinguishing Agents: Carbon dioxide, foam, dry chemical
Hazardous Products formed
by Fire or Thermal Decomp Irritating organic vapors
Unusual Fire or
Explosion Hazards: None
Explosive Limits:
(% by volume in air)Lower Not available
(% by volume in air)Upper Not available
6. ACCIDENTAL RELEASE MEASURES
Steps to be taken in case
of spill or leak: Soak up in an inert absorbent. Store in a partly
filled, closed container until disposal.
7. HANDLING AND STORAGE
Safe Storage: Store below 100 deg. F
(Contact Loctite Customer Service 1-800-243-4874 for shelf Life information)
Handling: Avoid prolonged skin contact. Keep away from eyes.
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 03 of 04
Product Name: 271(TM) High Strength Threadlocker Red
Item No.: 27100
8. EXPOSURE CONTROLS, PERSONAL PROTECTION
Eyes: Safety glasses or goggles.
Skin: Neoprene, rubber, or butyl rubber gloves.
Ventilation: Does not apply
See Section 2 for Exposure Limits.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Red liquid
Odor: Mild
Boiling Point: More than 300掳F
pH: Does not apply
Solubility in Water: Slight
Specific Gravity 1.10 at 80掳F
Volatile Organic Compound
(EPA Method 24) 12.0%; 132 g/l
Vapor Pressure: Less than 5mm at 80掳F
Vapor Density: Not available
Evaporation Rate
(Ether = 1) Not available
10. STABILITY AND REACTIVITY
Stability: Stable
Hazardous Polymerization: Will not occur
Incompatibility: None
Hazardous Decomposition
Products (non-thermal): None
11. TOXICOLOGICAL INFORMATION
See Section 3.
12. ECOLOGICAL INFORMATION
No data available
13. DISPOSAL CONSIDERATIONS
Recommended methods of
disposal: Incinerate following EPA and local regulations.
EPA Hazardous Waste
Number NH - Not a RCRA Hazardous Waste Material
LOCTITE CORPORATION 09/11/96
ROCKY HILL, CONNECTICUT 06067
EMERGENCY PHONE: (860) 571-5100
MATERIAL SAFETY DATA SHEET Page 04 of 04
Product Name: 271(TM) High Strength Threadlocker Red
Item No.: 27100
14. TRANSPORT INFORMATION
DOT (49 CFR 172)
Domestic Ground Transport
Proper Shipping Name: Unrestricted
Hazard Class or
Division: Unrestricted
Identification Number: None
Marine Pollutant: None
IATA
Proper Shipping Name: Unrestricted
Class or Division: Unrestricted
UN or ID Number: None
15. REGULATORY INFORMATION
CA Proposition 65: This product contains Saccharin. No prop65 hazard
warning is necessary if this product is used as
reasonably anticipated.
16. OTHER INFORMATION
Estimated NFPA(R) Code:
Health Hazard: 1
Fire Hazard: 1
Reactivity Hazard: 1
Specific Hazard: Does not apply
Estimated HMIS(R) Code:
Health Hazard: 1
Flammability Hazard: 1
Reactivity Hazards: 1
Personal Protection: See Section 8.
NFPA is a registered trademark of the National Fire Protection Assn.
HMIS is a registered trademark of the National Paint and Coatings Assn.
Prepared By: Stephen Repetto
Title: Research Chemist, Environmental Health & Safety
Company: Loctite Corp., 1001 Tr Br Cr, Rocky Hill CT 06067
(24hr.) Phone: (860) 571-5100
Revision Date: January 22, 1996 Revision: 0025