                                   Material Safety Data Sheet
Gen-Probe Incorporated Phone: 858-410-8000
10210 Genetic Center Drive Prepared: 1/26/06
San Diego, CA 92121-4362 Updated:
Page 1 of 6


Product Name: Syschek
Used In: BS0250
301078
MSDS Number: 1

I. Product and Company Description

Gen-Probe Incorporated.
10210 Genetic Center Drive
San Diego, CA 92121-4362

For Product Information/Emergency Phone Number:
(800) 424-9300 (CHEMTREC US)
(703) 527-3887 (CHEMTREC International)
(858) 410-8000 (Gen-Probe Corporate Office)

For product use see insert
Luminometer reference check

Chemical Name or Synonym:
N/A

II. Chemical Composition

Component CAS # EC # %Composition
Water 7732-18-5 231-791-2 99-97
Lithium Lauryl Sulfate 2044-56-6 218-058-2 1-3

III. Hazards Identification

A. Emergency Overview:
Information Pertaining To Particular Dangers For Man And Environment:
Irritant to eyes, mucous membranes and skin. Not to be inhaled or taken internally.

Physical Appearance:
Clear, colorless liquid with no odor

B. Potential Health Effects:
Acute Eye:
May cause irritation and redness with prolonged exposure and concentration.

Acute Skin:
May cause irritation.
Material Safety Data Sheet
Gen-Probe Incorporated Phone: 858-410-8000
10210 Genetic Center Drive Prepared: 1/26/06
San Diego, CA 92121-4362 Updated:
Page 2 of 6

Acute Inhalation:
May be harmful if inhaled.

Acute ingestion:
May be harmful if swallowed.

Medical Conditions Generally Aggravated by Exposure:
Not Determined.

IV. First Aid Measures

First Aid Measures for Accidental:
Eye Exposure:
Immediately flush eyes with copious amounts of water for at least 15 minutes. If irritation
develops, SEEK MEDICAL ATTENTION.

Skin Exposure:
Wash affected areas with soap and water. If irritation develops, SEEK MEDICAL ATTENTION.

Inhalation:
Move to fresh air. If not breathing, administer artificial respiration. If breathing is difficult, give
oxygen. SEEK MEDICAL ATTENTION.

Ingestion:
If swallowed, rinse mouth out with water. Never give fluids or induce vomiting if the victim is
unconscious or having convulsions. SEEK MEDICAL ATTENTION.

V. Fire Fighting Measures

Fire Hazard Data:
Autoignition: NA

Flash Point: NA

Flammability Limits (vol/vol%): Lower: Upper:
NA NA

Extinguishing Media:
Use extinguishing media appropriate for surrounding fire

Special Fire Fighting Procedures:
None

Unusual Fire and Explosion Hazards:
None
Material Safety Data Sheet
Gen-Probe Incorporated Phone: 858-410-8000
10210 Genetic Center Drive Prepared: 1/26/06
San Diego, CA 92121-4362 Updated:
Page 3 of 6

VI. Accidental Release Measures

Cleanup and Disposal of Spill:
Wear suitable laboratory protective clothing. Discard any product, residue, disposable container or liner in
full compliance with national regulations.

VII. Handling and Storage

Handling/Storage:
Observe good laboratory handling practices. Always wash hands thoroughly after removing protective
gloves. Avoid breathing vapors or mists. Ensure containers are labeled and tightly closed. Store product
in a temperature controlled environment (15-30掳C/59-86掳F).

VIII. Exposure Controls / Personal Protection

Exposure Guidelines:

Component ACGIH NIOSH OSHA-PELs
Water NA NA NA
Lithium Lauryl Sulfate ND ND ND

Engineering Controls:
Ventilation must be adequate to maintain the ambient workplace atmosphere below the exposure limit(s)
outlined in the MSDS. General room ventilation is satisfactory under anticipated use conditions.

Respiratory Protection:
Not required under anticipated use conditions.

Eye / Face Protection:
Wear appropriate safety glasses with side shields or chemical goggles as described by OSHA鈥檚 eye and
face protection regulations in 29CFR 1910.133 or European Standard EN166.

Skin Protection:
Wear chemical resistant gloves (such as latex or neoprene) and protective clothing to minimize skin
contact.

IX. Physical and Chemical Properties

Physical State: Clear liquid

Odor: None

pH: 3

Specific Gravity: approx. 1

Water Solubility: Soluble
Material Safety Data Sheet
Gen-Probe Incorporated Phone: 858-410-8000
10210 Genetic Center Drive Prepared: 1/26/06
San Diego, CA 92121-4362 Updated:
Page 4 of 6

Melting Point: ND

Freezing Point ND

Boiling Point: ND

Vapor Pressure: ND

Vapor Density: ND

Percent Volatiles by Volume: ND

Viscosity: ND

Molecular Weight: ND

X. Stability and Reactivity

Chemical Stability:
Stable

Conditions to Avoid:
None

Materials / Chemicals to Be Avoided:
Strong oxidizing agents.

Hazardous Decomposition Products:
Thermal decomposition may produce carbon oxides.

Hazardous Polymerization:
Will not occur.

XI. Toxicological Information

Carcinogenicity:
NTP: NO
IARC: NO
OSHA: NO

Acute Dermal Toxicity:
For Sodium Phosphate: Skin rabbit, standard Draize, 500 mg/24H, mild

Acute Oral Toxicity:
For Sodium Phosphate: Oral rat LD50: 17 g/kg

Acute Inhalation Toxicity:
ND
Material Safety Data Sheet
Gen-Probe Incorporated Phone: 858-410-8000
10210 Genetic Center Drive Prepared: 1/26/06
San Diego, CA 92121-4362 Updated:
Page 5 of 6

Chronic Toxicity:
Mutagenicity: ND
Reproductive effects: ND

XII. Ecological Information

Ecotoxicological Information:
Not Determined

XIII. Disposal Considerations

Waste Disposal Method:
Discard any product, residue, disposable container or liner in full compliance with national regulations.

Container Handling and Disposal:
Dispose of container and unused contents in accordance with national regulations.

XIV. Transportation Information

Shipping Name:

Not Regulated
Proper Shipping Name
Not Regulated
ADR/RID/IMO/ICAO Hazard Class
/US DOT
Not Regulated
ID Number
Not Regulated
Packaging Group

XV. Regulatory Information

U.S. Federal Regulations:

SARA Title III Hazard Classes:
Fire Hazard: No
Reactive Hazard: No
Release of Pressure: No
Acute Health Hazard: No
Chronic Health Hazard: No

TSCA
All components of this product are on the TSCA inventory or are not required to be listed.


Other Regulations:
U.S. State
None
Material Safety Data Sheet
Gen-Probe Incorporated Phone: 858-410-8000
10210 Genetic Center Drive Prepared: 1/26/06
San Diego, CA 92121-4362 Updated:
Page 6 of 6

European/International Regulations
Risk Phrases:
R 36/38 Irritating to eyes and skin
Safety Phrases:
S2 Keep out of the reach of children
S13 Keep away from food, drink and animal feeding stuffs.
S36 Wear suitable protective clothing
S46 If swallowed, seek medical advice immediately and show this container or label.

EU Hazard Symbol:




Xi: Irritant

XVI. Other Information

National Paint & Coating Hazardous Materials Identification System 鈥? HMIS(R):

Health Hazard: 2
Flammability: 0
Reactivity: 0

Key Legend Information:
N/A 鈥? Not Applicable
ND 鈥? Not Determined
ACGIH 鈥? American Conference of Governmental Industrial Hygienists
OSHA 鈥? Occupational Safety and Health Administration
TLV 鈥? Threshold Limit Value
PEL 鈥? Permissible Exposure Limit
TWA 鈥? Time Weighted Average
STEL 鈥? Short Term Exposure Limit
NTP 鈥? National Toxicology Program
IARC 鈥? International Agency for Research on Cancer

The information contained herein is based on the data available to us and is believed to be
correct. However Gen Probe Incorporated makes no warranty, expressed or implied regarding the
accuracy of this data or the results to be obtained from the use thereof.

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
gen-probe_com---302352.asp N/A
gen-probe_com---302352jp.asp N/A
gen-probe_com---302352pt.asp 139-33-3 10049-21-5 7783-20-2 77-92-9
gen-probe_com---302355.asp N/A
gen-probe_com---302355jp.asp N/A
gen-probe_com---302355sv.asp N/A
gen-probe_com---302380.asp 7681-52-9
gen-probe_com---302382.asp N/A
gen-probe_com---302554uk.asp N/A
gen-probe_com---302556uk.asp N/A
gen-probe_com---procleix_tcr_modifier_400174.asp 7732-18-5 1310-65-2
gen-probe_com---procleix_tigris_wnv_controls_kit.asp 7365-45-9 2044-56-6 110-16-6 1310-66-3
gen-probe_com---procleix_wnv_assay_kit.asp 7365-45-9 2044-56-6 110-15-6 1310-66-3
gen-probe_com---syschek.asp 7732-18-5 2044-56-6
hc-sc_gc_ca---eq-paq-eng.asp N/A
hc-sc_gc_ca---tab_com-eng.asp N/A
indium_com---97857.asp N/A
irmteam_com---msds-dynonobel-uan32.asp 0057-13-6 6484-52-2 7732-18-5
irmteam_com---msds-uan32.asp 0057-13-6 6484-52-2 7732-18-5
irmteam_com---msdsats.asp 7783-18-3
irmteam_com---msdsdynonobel-ulbu.asp 57-13-6 108-19-0
kumiai-chem_co_jp---20080320182133266.asp N/A
kumiai-chem_co_jp---20080321225241031.asp N/A
kumiai-chem_co_jp---20080321225624011.asp N/A
kumiai-chem_co_jp---20080321225728090.asp N/A
kumiai-chem_co_jp---20080321225937045.asp N/A
kumiai-chem_co_jp---20080321230231562.asp N/A
kumiai-chem_co_jp---20080321230424801.asp N/A
kumiai-chem_co_jp---20080321230514263.asp N/A
kumiai-chem_co_jp---20080321230612305.asp N/A
kumiai-chem_co_jp---20080321230706590.asp N/A
kumiai-chem_co_jp---20080321230802503.asp N/A
kumiai-chem_co_jp---20080321230853001.asp N/A
kumiai-chem_co_jp---20080321231039853.asp N/A
kumiai-chem_co_jp---20080321231126626.asp N/A
kumiai-chem_co_jp---20080321231409605.asp N/A
kumiai-chem_co_jp---20080323013748177.asp N/A
kumiai-chem_co_jp---20080323015025168.asp N/A
kumiai-chem_co_jp---20080323015245484.asp 80844-07-1
kumiai-chem_co_jp---20080323015404338.asp N/A
kumiai-chem_co_jp---20080323020605793.asp N/A
kumiai-chem_co_jp---20080323021409224.asp N/A
kumiai-chem_co_jp---20080323022257940.asp N/A
kumiai-chem_co_jp---20080323022358948.asp N/A
kumiai-chem_co_jp---adomaiya_1_ry.asp N/A
kumiai-chem_co_jp---adomaiya_f.asp N/A
kumiai-chem_co_jp---adomaiya_hry.asp N/A
kumiai-chem_co_jp---adomaiya_k_dl.asp N/A
kumiai-chem_co_jp---adomaiya_s.asp N/A
kumiai-chem_co_jp---adomaiya_wg.asp N/A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC