Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: hc-sc_gc_ca---tab_com-eng.asp
OFFICIAL METHOD
Determination of the Disintegration Time of Tablets




Published by authority of the
Minister of Health




Date 1989/07/05

Administrative Changes Date 2003/11/17




Health Products and Food Branch
Health Canada Determination of the Disintegration Time of Tablets
Official Method DO-25

APPLICATION
I.

This method shall be used to measure the disintegration time of uncoated, plain coated and enteric
coated tablets, intended to be swallowed whole, as described in Section C.01.015 of the Food and
Drug Regulations.

APPARATUS
II.

A device for raising and lowering the basket-rack assembly, vertically along its axis, in the
(1)
immersion fluid at a constant frequency between 28 and 32 cycles per minute through a
distance of not less that 5.0 cm and not more than 6.0 cm.

A basket-rack assembly (see Figures I and II) containing six open-ended glass tubes, each
(2)
7.75 卤 0.25 cm long and having an inside diameter of not less than 21.0 mm and not more that
22.5 mm and a wall approximately 2 mm thick. The tubes are held in a vertical position by two
superimposed plastic plates each about 9 cm in diameter and 6 mm in thickness, with six holes,
each about 24 in diameter, equidistant from the centre of the plate and equally spaced from one
another. These holes are bored completely through the lower plate, but only through the lower
4 mm of the upper plate. The upper 2 mm of the plate contains six 21 mm diameter holes
concentric with the 24 mm holes in the bottom portion of the plate, thereby forming a lip to
retain the glass tubes. Alternatively the holes may be bored through the upper plate which is
then covered with a stainless steel disk perforated by six holes about 22 mm in diameter which
fit over the tubes. Attached to the underside of the lower plate in woven stainless steel wire
cloth made from wire 0.635 mm in diameter having mesh apertures of about 2.0 mm and which
retains the tubes. The plates are held rigidly in position, 77.5 mm apart, by means of 3 metal
bolts, about 6.0 mm in diameter, passing through the upper and lower plates. A metal rod,
about 8 cm in length and 7 mm in diameter, is also fixed to the centre of the upper plate and
provided with a suitable means to suspend the assembly from the raising or lowering device
(NOTE 1).

Six slatted and perforated cylindrical disks 9.5 卤 0.15 mm thick and 20.7 卤 0.15 mm in
(3)
diameter. Each disk is made of a suitable transparent plastic material having a specific gravity of
between 1.18 and 1.20. Five 2 mm holes extend between the ends of the disk, one of the holes
being through the cylinder axis and the others parallel with it, equally spaced on a 6 mm radium
around it. Equally spaced on the sides of the disk are four V-shaped notches. The dimensions
of each notch are such that the openings on the bottom of the disk are 1.6 mm square and those
on the top are 9.5 mm wide and 2.55 mm deep at the centre (and about 1.3 mm deep at the
ends). All surfaces of the disk are smooth.


Date: 1989/07/05; Administrative Changes Date: 2003/11/17 1
Determination of the Disintegration Time of Tablets Health Canada
DO-25 Official Method

Six plungers each consisting of two plastic disks and a 3.2 mm diameter stainless steel rod
(4)
approximately 9 cm in length. The lower disk is cylindrical and smooth, 7.5 卤 0.15 mm thick
and 20.7 卤 0.15 mm in diameter. Six holes, 4.0 卤 0.1 mm in diameter, are bored through the
disk symmetrically distributed in a circle around the axis of the disk. One end of the stainless
steel rod is permanently embedded in the centre and flush with the lower edge of the disk. The
upper disk is smooth and approximately 7.5 mm thick. The lower half has a diameter of 20.7 卤
0.15 mm and the upper half has a diameter of approximately 24 mm. This provides for an
indent to enable the seating of the plunger in the glass tube. Twelve holes 2.4 卤 0.1 mm in
diameter, are bored through the disk symmetrically in two circles around the axis. A 3.2 mm
hole is bored through the axis of the disk, through which the stainless steel rod is inserted such
that when the apparatus is assembled the lower edge of the bottom disk is 2.8 卤 0.1 cm from
the bottom of the glass tube.

A cylindrical glass jar having an outside diameter of about 15 cm and a height of 20-21 cm.
(5)

A water bath or other suitable means of maintaining the text fluid in the jar at 37 卤 2掳C.
(6)




2 Date: 1989/07/05; Administrative Changes Date: 2003/11/17
Health Canada Determination of the Disintegration Time of Tablets
Official Method DO-25


FIGURE I

Diagram of Assembled Apparatus




Date: 1989/07/05; Administrative Changes Date: 2003/11/17 3
Determination of the Disintegration Time of Tablets Health Canada
DO-25 Official Method


FIGURE II

Diagram of Glass Tube, Plastic Disk and Plunger




4 Date: 1989/07/05; Administrative Changes Date: 2003/11/17
Health Canada Determination of the Disintegration Time of Tablets
Official Method DO-25

MATERIALS AND SOLUTIONS
III.

Water. Use distilled water.
(1)

Hydrochloric Acid. Use ACS reagent grade.
(2)

Sodium Chloride. Use ACS reagent grade.
(3)

Pepsin. Use FCC grade.
(4)

Potassium Phosphate, Monobasic. Use ACS reagent grade.
(5)

Pancreatin. Use USP grade.
(6)

Hydrochloric Acid Solution (0.1 M). Dilute 8.5 ml of hydrochloric acid to 1000 ml with water,
(7)
or dilute a commercial volumetric solution with water to obtain a final concentration of 0.1 M.

Sodium Hydroxide Solution (0.2 M). Use ACS reagent grade. Dissolve 8 g of sodium
(8)
hydroxide in, and dilute to 1000 ml with, carbon dioxide-free water, or dilute a commercial
volumetric solution with carbon dioxide-free water ta give a final concentration of 0.2 M.

Simulated Gastric Fluid. Dissolve 2.0 g of sodium chloride and 3.2 g of pepsin in 500 ml of
(9)
water, add 7.0 ml of hydrochloric acid and dilute to 1000 ml with water. The pH is about 1.2.
(NOTE 2).

Simulated Intestinal Fluid. Dissolve 6.8 g of potassium phosphate, monobasic, in 250 ml of
(10)
water. Mix with 190 ml of Sodium Hydroxide Solution (0.2 M) and 400 ml of water. Add 10.0
g of pancreatin, mix and adjust the pH of the resulting solution to 7.5 卤 0.1 with Sodium
Hydroxide Solution (0.2 M). dilute with water to 1000 ml. (NOTE 2).

PROCEDURE
IV.

The test shall be carried out in accordance with the following instructions:

Uncoated and Plain Coated Tablets

assemble the apparatus when the device for raising and lowering the basket-rack assembly is at
(1)
rest and its cylinder is in the extreme down position;


Date: 1989/07/05; Administrative Changes Date: 2003/11/17 5
Determination of the Disintegration Time of Tablets Health Canada
DO-25 Official Method

with 2.5 L of water in the cylindrical jar, adjust the apparatus until the level of fluid in the jar
(2)
coincides approximately with the mid-line of the upper plastic plate (see Figure II);

maintain the temperature of the fluid at 37 卤 2掳C by a suitable means as indicated under
(3)
APPARATUS (6);

remove the basket-rack assembly from the water and disassemble;
(4)

select at random six tablets from the sample and place one in each of the tubes of the basket-
(5)
rack assembly;

place a plastic disk on each tablet, ensuring the orientation specified under APPARATUS (3)
(6)
and then a plunger as specified under APPARATUS (4), (See Figure I);

re-insert the assembly ln the water and set the machine in motion;
(7)

the plastic disks should travel up and down freely, exerting a gentle rubbing action on each
(8)
tablet;

after 45 or 60 minutes (see (10) and (11) below), remove the basket-rack assembly from the
(9)
water;

uncoated tablets pass the test if each of the six uncoated tablets disintegrates (NOTE 3) in not
(10)
more that 45 minutes;

plain coated tablets pass the test if each of the six plain coated tablets disintegrates in not more
(11)
than 60 minutes. If any of the tablets has not disintegrated at the end of 60 minutes, repeat the
test on a further six plain coated tablets, replacing the water in the cylindrical jar with
Hydrochloric Acid Solution (0.1 M). The tablets pass the test if each of the six tablets
disintegrates within 60 minutes in this acid medium.

Enteric Coated Tablets

assemble the apparatus as described in (1) to (3) under "Uncoated and Plain Coated Tablets",
(1)
using 2.5 L of Simulated Gastric Fluid in place of water;

remove the basket-rack assembly from the Simulated Gastric Fluid and disassemble;
(2)

select at random six tablets from the sample and place one in each of the tubes of the basket-
(3)
rack assembly;

place a plunger in each tube as specified under Apparatus (4) and as shown in Figure II
(4)
(omitting the plastic disk);


6 Date: 1989/07/05; Administrative Changes Date: 2003/11/17
Health Canada Determination of the Disintegration Time of Tablets
Official Method DO-25


(5) insert the assembly in the Simulated Gastric fluid and set the machine in motion;

(6) at the end of 60 minutes of operation, remove the basket-rack assembly from the fluid and
gently rinse with water;

(7) enteric coated tablets fail the test if any now show distinct evidence of disintegration;

(8) replace the Simulated Gastric Fluid in the jar with 2.5 L of Simulated Intestinal Fluid;

(9) remove the plungers, place a plastic disk on each tablet ensuring the orientation specified under
APPARATUS (3);

(10) re-insert the plunger as specified under APPARATUS (4);

(11) continue the test by setting the machine in motion;

(12) after 60 minutes remove the basket-rack assembly from the fluid;

(13) enteric coated tablets pass the test if each of the six tablets disintegrates (NOTE 3) in not more
than 60 minutes in the Simulated Intestinal Fluid

V. NOTES

1. The design of the basket-rack assembly may be varied somewhat provided that the
specifications for the glass tubes, disks, plungers, plunger position and wire mesh are
maintained.

2. Stock solution of the digestive fluids may be prepared; however, the enzymes must be omitted
to avoid decomposition. The pepsin or pancreatin shall be added to the respective stock
solution in the proper quantity just before use.

3. Disintegration is considered to be that state in which any residue, except fragments of insoluble
coating, remaining on the screen is a soft mass having no palpably firm core.

The method described above, being comprised of seven pages including Figures I and II and identified
as DO-25, DETERMINATION OF THE DISINTEGRATION TIME OF TABLETS and dated July
5, 1989, is hereby designated the "official method" referred to in Section C.01.015 of the Food and
Drug Regulations.




Date: 1989/07/05; Administrative Changes Date: 2003/11/17 7

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
gen-probe_com---302352.asp N/A
gen-probe_com---302352jp.asp N/A
gen-probe_com---302352pt.asp 139-33-3 10049-21-5 7783-20-2 77-92-9
gen-probe_com---302355.asp N/A
gen-probe_com---302355jp.asp N/A
gen-probe_com---302355sv.asp N/A
gen-probe_com---302380.asp 7681-52-9
gen-probe_com---302382.asp N/A
gen-probe_com---302554uk.asp N/A
gen-probe_com---302556uk.asp N/A
gen-probe_com---procleix_tcr_modifier_400174.asp 7732-18-5 1310-65-2
gen-probe_com---procleix_tigris_wnv_controls_kit.asp 7365-45-9 2044-56-6 110-16-6 1310-66-3
gen-probe_com---procleix_wnv_assay_kit.asp 7365-45-9 2044-56-6 110-15-6 1310-66-3
gen-probe_com---syschek.asp 7732-18-5 2044-56-6
hc-sc_gc_ca---eq-paq-eng.asp N/A
hc-sc_gc_ca---tab_com-eng.asp N/A
indium_com---97857.asp N/A
irmteam_com---msds-dynonobel-uan32.asp 0057-13-6 6484-52-2 7732-18-5
irmteam_com---msds-uan32.asp 0057-13-6 6484-52-2 7732-18-5
irmteam_com---msdsats.asp 7783-18-3
irmteam_com---msdsdynonobel-ulbu.asp 57-13-6 108-19-0
kumiai-chem_co_jp---20080320182133266.asp N/A
kumiai-chem_co_jp---20080321225241031.asp N/A
kumiai-chem_co_jp---20080321225624011.asp N/A
kumiai-chem_co_jp---20080321225728090.asp N/A
kumiai-chem_co_jp---20080321225937045.asp N/A
kumiai-chem_co_jp---20080321230231562.asp N/A
kumiai-chem_co_jp---20080321230424801.asp N/A
kumiai-chem_co_jp---20080321230514263.asp N/A
kumiai-chem_co_jp---20080321230612305.asp N/A
kumiai-chem_co_jp---20080321230706590.asp N/A
kumiai-chem_co_jp---20080321230802503.asp N/A
kumiai-chem_co_jp---20080321230853001.asp N/A
kumiai-chem_co_jp---20080321231039853.asp N/A
kumiai-chem_co_jp---20080321231126626.asp N/A
kumiai-chem_co_jp---20080321231409605.asp N/A
kumiai-chem_co_jp---20080323013748177.asp N/A
kumiai-chem_co_jp---20080323015025168.asp N/A
kumiai-chem_co_jp---20080323015245484.asp 80844-07-1
kumiai-chem_co_jp---20080323015404338.asp N/A
kumiai-chem_co_jp---20080323020605793.asp N/A
kumiai-chem_co_jp---20080323021409224.asp N/A
kumiai-chem_co_jp---20080323022257940.asp N/A
kumiai-chem_co_jp---20080323022358948.asp N/A
kumiai-chem_co_jp---adomaiya_1_ry.asp N/A
kumiai-chem_co_jp---adomaiya_f.asp N/A
kumiai-chem_co_jp---adomaiya_hry.asp N/A
kumiai-chem_co_jp---adomaiya_k_dl.asp N/A
kumiai-chem_co_jp---adomaiya_s.asp N/A
kumiai-chem_co_jp---adomaiya_wg.asp N/A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC