DEVCON FLEXANE ACCELERATOR MSDS
ISSUE DATE: 20 September, 2007
MATERIAL SAFETY DATA SHEET
FLEXANE ACCELERATOR
1 IDENTIFICATION OF THE MATERIAL AND SUPPLIER
PRODUCT NAME: DEVCON FLEXANE ACCELERATOR
PRODUCT NO. D15990 (Accelerator for two part polyurethane system)
SUPPLIER ITW POLYMERS & FLUIDS ITW POLYMERS & FLUIDS (NZ)
100 HASSALL ST UNIT 2 / 38 TRUEGOOD DRIVE
WETHERILL PARK EAST TAMAKI, 2013
NEW SOUTH WALES AUCKLAND
AUSTRALIA NEW ZELAND
T: 02 9757 8800 T: 09 272 1945
F: 02 9757 3855 F: 09 273 6489
EMERGENCY PHONE: T: 02 9757 8800 T: 09 272 1945
2 HAZARDS IDENTIFICATION
NON-HAZARDOUS SUBSTANCE. NON-DANGEROUS GOODS
(According to the criteria of the NOHSC and the ADG-6 code)
SIGNAL WORD(S)
Not considered hazardous in accordance with NOHSC criteria.
RISK PHRASES
None allocated
.
SAFETY PHRASES
None allocated
3 COMPOSITION / INFORMATION ON INGREDIENTS
Name CAS-No. Content Classification
OLEIC ACID 112-80-1 60 - < 100 %
4 FIRST AID MEASURES
GENERAL INFORMATION
In case of accident or if you feel unwell, seek medical advice immediately Show label or this safety data sheet to doctor in attendance if
possible.
INHALATION
Move the exposed person to fresh air at once. Contact physician if discomfort continues.
INGESTION
Do not induce vomiting. Rinse mouth with water. Drink plenty of water. Get medical attention.
SKIN CONTACT
Remove affected person from source of contamination. Wash skin thoroughly with soap and warm water for several minutes. Contact
physician if irritation persists.
EYE CONTACT
Promptly wash eyes with plenty of clean water while lifting the eye lids. Continue to rinse for at least 15 minutes and get medical
attention. Contact physician if irritation persists.
5 FIRE FIGHTING MEASURES
SUITABLE EXTINGUISHING MEDIA
Fire can be extinguished using: Water Spray, Foam, Carbon Dioxide (CO2). Dry Chemicals.
DEVCON FLEXANE ACCELERATOR MSDS Page 1 of 4
DEVCON FLEXANE ACCELERATOR MSDS
SPECIFIC HAZARDS
Avoid breathing fire vapours.
PROTECTIVE EQUIPMENT FOR FIREFIGHTERS
Self contained breathing apparatus and full protective clothing must be worn in case of fire.
SPECIAL FIRE FIGHTING PROCEDURES
Keep upwind to avoid fumes. Keep run-off water out of sewers and watercourses. Dike for water control.
6 ACCIDENTAL RELEASE MEASURES
PERSONAL PRECAUTIONS
Wear protective clothing as described in Section 8 of this safety data sheet.
ENVIRONMENTAL PRECAUTIONS
Do not allow to enter drains, sewers or watercourses. Spillages or uncontrolled discharges into watercourses must be IMMEDIATELY
alerted to the Environmental Agency or other appropriate regulatory body.
SPILL CLEAN UP METHODS
Absorb with sand or other inert absorbent. Transfer to a container for disposal. Containers with collected spillage must be properly
labeled with correct contents and hazard symbol.
7 HANDLING AND STORAGE
USAGE PRECAUTIONS
Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not
exceeded. Do not eat, drink or smoke when using the product. Observe good industrial hygiene practices.
STORAGE PRECAUTIONS
Store in tightly closed original container in a cool, dry well-ventilated place. Keep away from heat, sparks and open flame.
8 EXPOSURE CONTROL / PERSONAL PROTECTION
No exposure data available for product or ingredients.
PROTECTIVE EQUIPMENT
PROCESS CONDITIONS
Provide eyewash, quick drench.
ENGINEERING MEASURES
Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not
exceeded.
RESPIRATORY EQUIPMENT
Not usually required in well ventilated areas.
Select and use respirators in accordance with AS/NZS 1715/1716.
In poorly ventilated areas use Type A organic vapour/gas filter with half face piece.
When sanding/grinding cured product the use of a P1 dust mask (disposable) or with replaceable filters is recommended.
Filter capacity and respirator type depends on exposure levels and type of contaminant. If entering spaces where the airborne
concentration of a contaminant is unknown then the use of a Self-contained breathing apparatus (SCBA) with positive pressure air
supply complying with AS/NZS 1715 / 1716, or any other acceptable International Standard is recommended.
HAND PROTECTION
Use protective gloves made of: Rubber or plastic.
EYE PROTECTION
Wear approved chemical safety goggles where eye exposure is reasonably probable.
HYGIENE MEASURES
DEVCON FLEXANE ACCELERATOR MSDS Page 2 of 4
DEVCON FLEXANE ACCELERATOR MSDS
Keep away from food, drink and animal feeding stuffs. Good personal hygiene is necessary. Wash hands and contaminated areas with
water and soap before leaving the work site. Do not eat, drink or smoke when using the product. Change work clothing daily before
leaving work place.
SKIN PROTECTION
Apron or protection suit should be worn.
9 PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE Liquid
COLOUR Colourless
ODOUR Slight odour
SOLUBILITY Slightly soluble in water
BOILING POINT (掳C) > 280 RELATIVE DENSITY 1.12 @ 20 潞C
pH-VALUE, CONC. SOLUTION 8.5 @ 20 潞C FLASH POINT (掳C) >183
AUTO IGNITION TEMPERATURE (潞C) > 350
10 STABILITY & REACTIVITY
STABILITY
Stable under normal temperature conditions and recommended use.
CONDITIONS TO AVOID
Avoid heat, flames and other sources of ignition.
MATERIALS TO AVOID
Avoid contact with: Strong acids. Strong oxidising agents. Strong alkalies.
HAZARDOUS DECOMPOSITION PRODUCTS
Fire or high temperatures create: Oxides of: Carbon monoxide (CO), Carbon dioxide (CO2), Other toxic vapours / fumes.
11 TOXICOLOGICAL INFORMATION
INGESTION
Harmful if swallowed.
SKIN CONTACT
Avoid contact with skin
EYE CONTACT
Avoid contact with eyes.
12 ECOLOGICAL INFORMATION
ECOTOXICITY
Avoid release to the environment.
MOBILITY
Do not discharge into drains, water courses or onto the ground.
DEGRADABILITY
No available information
13 DISPOSAL INFORMATION
DISPOSAL METHODS
Dispose of waste and residues in accordance with local authority requirements.
14 TRANSPORT INFORMATION
Not classified as Dangerous Goods in accordance with ADG-6.
Not covered by International regulations (IMDG, IATA, ADR/RID)
DEVCON FLEXANE ACCELERATOR MSDS Page 3 of 4
DEVCON FLEXANE ACCELERATOR MSDS
15 REGULATORY INFORMATION
POISONS SCHEDULE: None allocated
6 OTHER INFORMATION
REVISION DATE: 20 September, 2007
Contact Point: Technical Manager (02) 9757 8800 (Australia)
DISCLAIMER
This information relates only to the specific material designated and may not be valid for such material used in combination
with any other materials or in any process. Such information is, to the best of the company's knowledge and belief, accurate
and reliable as of the date indicated. However, no warranty guarantee or representation is made to its accuracy, reliability or
completeness. It is the user's responsibility to satisfy himself as to the suitability of such information for his own particular use.
DEVCON FLEXANE ACCELERATOR MSDS Page 4 of 4
|