MATERIAL SAFETY DATA SHEET
http://www.rayovac.com
1. We would like to inform our customers that these batteries are exempt articles and are not subject to the 29 CFR
1910.1200 OSHA requirement, or to the Canadian WHMIS requirements and the sheets are supplied as a service to you. For
other MSDSs and related information, visit: http://www.rayovac.com/technical/msds.htm.
2. THESE BATTERIES ARE SUITABLE FOR LANDFILL DISPOSAL (SEE SECTION 7).

1. IDENTIFICATION
PRODUCT NAME: Rechargeable Alkaline Batteries

SIZES: All

EMERGENCY TELEPHONE NUMBER: 800-424-9300 (24 hr, Chemtrec)

Environmental Health & Safety Information: 608-275-2482

EDITION DATE:03/05/2007 APPROVED BY: Kevin J. Domack



2. INGREDIENTS

INGREDIENT NAME CAS # % TLV*
C5.0 mg/m3 (Mn, TWA)
Manganese Dioxide 1313-13-9 32 - 38
Steel 7439-89-6 19 - 23 Not Listed
5 mg/m3 (ZnO, Dust, TWA)
Zinc 7440-66-6 11 - 16
Potassium Hydroxide 1310-58-3 5-9 Not Listed
Graphite 7782-42-5 3-5 15 mppcf
15 mg/m3 (TWA)
Barium Sulfate 7727-43-7 <5
0.01 mg/m3 (TWA)
Silver (soluble, as Ag) 7440-22-4 <0.5
Water, paper, plastic, other -- Balance --
*Source: OSHA 29 CFR 1910.1000 Table Z-1, 2 or 3 3-01-2007



3. PHYSICAL DATA

Boiling Point @ 760 mm Hg (掳C): NA
Vapor Pressure (mm Hg @ 25掳C): NA
Vapor Density (Air = 1): NA
Density (grams/cc): NA
Percent Volatile by Volume (%): NA
Evaporation Rate (Butyl Acetate = 1): NA
Physical State: NA
Solubility in Water (% by Weight): NA
pH: NA
Appearance and Odor: geometric solid object




NA = Not Applicable Rechargeable Alkaline Batteries 03-05-2007 Page 1 of 3
4. FIRE & EXPLOSION HAZARD DATA
FLASH POINT: NA LOWER (LEL): NA

FLAMMABLE LIMITS IN AIR (%): NA UPPER (UEL): NA

EXTINGUISHING MEDIA: Use water, foam or dry powder, as appropriate.

AUTO-IGNITION: NA

SPECIAL FIRE FIGHTING PROCEDURES: As with any fire, wear self-contained breathing apparatus to
avoid inhalation of hazardous decomposition products (See section 2).

SPECIAL FIRE EXPLOSION HAZARDS: Like any sealed container, battery cells may rupture when
exposed to excessive heat; this could result in the release of flammable or corrosive materials.



5. HEALTH HAZARD DATA

THRESHOLD LIMIT VALUE (TLV) AND SOURCE: NA

EFFECTS OF OVEREXPOSURE: None. (In fire or rupture situation see section 2 and section 4)

EMERGENCY FIRST AID PROCEDURES:

Skin and Eyes:
In the event that battery ruptures, flush exposed skin with copious quantities of flowing lukewarm water for a
minimum of 15 minutes. Get immediate medical attention for eyes. Wash skin with soap and water.
Swallowing:
Ingestion of a battery can be harmful. Call The National Capital Poison Center (800-222-1222), day or night,
for advice and follow-up.

For more information, visit: http://www.nema.org/gov/ehs/committees/drybat/



6. REACTIVITY DATA
STABLE OR UNSTABLE: Stable

INCOMPATIBILITY (MATERIALS TO AVOID): NA

HAZARDOUS DECOMPOSITION PRODUCTS: NA

DECOMPOSITION TEMPERATURE (0掳F): NA

HAZARDOUS POLYMERIZATION: Will Not Occur

CONDITIONS TO AVOID: Avoid electrical shorting.




NA = Not Applicable Rechargeable Alkaline Batteries 03-05-2007 Page 2 of 3
7. SPILL OR LEAK PROCEDURES
PROCEDURES TO CONTAIN AND CLEAN UP LEAKS OR SPILLS: In the event of a battery rupture,
prevent skin contact and collect all released material in a plastic lined metal container.

REPORTING PROCEDURE: Report all spills in accordance with Federal, State and Local reporting
requirements.

WASTE DISPOSAL METHOD: When shredded per Toxicity Characteristic Leachate Procedure (TCLP)
parameters and tested per SW 846, 3rd Edition, Test Methods for Evaluating Solid Waste, independent
certified laboratory analyses have indicated these Rayovac battery types to have no hazardous waste
characteristics (per 40 CFR, Part 261.24) and can be landfilled if all other Federal, State and Local
regulations are complied with. For additional information on disposal or recycling options, visit:
http://www.nema.org/gov/ehs/committees/drybat/


8. PROTECTION INFORMATION
RESPIRATORY PROTECTION (SPECIFY TYPE): NA

VENTILATION: Local Exhaust: NA
Mechanical (General): NA
Special: NA
Other: NA

PROTECTIVE GLOVES: NA

EYE PROTECTION: NA

OTHER PROTECTIVE CLOTHING: NA


9. SPECIAL PRECAUTIONS
HANDLING AND STORAGE: Store in a dry place. Storing unpackaged cells together could result in cell
shorting and heat build-up. Charge Rayovac Rechargeable Alkaline (Renewal) Batteries only in a Rayovac
battery charger designed specifically for Rechargeable Alkaline batteries. See back of charger for details.
Placing these batteries in any other charging device may cause the batteries to burst and leak.

TRANSPORTATION-SHIPPING: These are "batteries, dry" and are not considered to be a "hazardous
material" per the Dept. of Transportation (USDOT) regulations or "dangerous goods" per the International
Air Transport Association (IATA) regulations. Shipments must comply with the general duty clause of
USDOT 49 CFR 172.102 (a) (1) special provision 130, 鈥渢o prevent shorting potential while transporting.鈥?


10. SARA 313
Notification is not required because these products are article(s) that do not release a covered toxic chemical
under the normal conditions of processing or use.


NOTICE: The information and recommendations set forth are made in good faith and are believed to be accurate at
the date of preparation. Rayovac Corporation makes no warranty expressed or implied.



NA = Not Applicable Rechargeable Alkaline Batteries 03-05-2007 Page 3 of 3

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
quickcable_com---510410.asp 115-10-6 7732-18-5 7632-00-0
quickcable_com---510420.asp 68476-86-8 102-71-6
quickcable_com---510430.asp 68476-86-8 102-71-6
quickcable_com---510450.asp 68476-86-8 111-76-2 64-17-5 108-10-1 67-56-1 7732-18-5
quickcable_com---510455.asp 68476-86-8 67-63-0 111-76-2
quickcable_com---5577.asp 7439-92-1 7440-36-0 7440-38-2 7440-31-5
quickcable_com---5611.asp N/A
quickcable_com---5702.asp N/A
quickcable_com---5950.asp 7440-50-8 7440-31-5
quickcable_com---604010.asp N/A
quickcable_com---6902.asp 63148-62-9
quickcable_com---msds_120131.asp 144-55-8 75-28-5 106-97-8 74-98-6 111-76-2
quickcable_com---msds_120132.asp 144-55-8 7732-18-5 75-28-5 74-98-6 111-76-2
quickcable_com---msds_120141.asp 8009-03-8 1330-20-7 6474-28-8 107-83-5 110-54-3 142-82-5
quickcable_com---msds_120142.asp 8009-03-8 1330-20-7 8052-41-3 107-83-5 110-54-3 142-82-5 100-41-4
quickcable_com---msds_6022_6023.asp N/A
quickcable_com---msds_6621_6622_6626_6628.asp 64742-52-5
rayovac_com---007121.asp 1313-13-9 7439-89-6 7440-66-6 1310-58-3 7782-42-5 7727-43-7 7440-22-4
rayovac_com---007122.asp 7440-22-4 7439-89-6 7440-66-6 1310-58-3 7782-42-5 7439-97-6 1313-13-9
rayovac_com---007123.asp 7439-97-6 7439-89-6 7440-66-6 1310-58-3 1313-13-9 03-05-2
rayovac_com---007124.asp 03-05-2 51311-17-2 108-32-7 9003-07-0 110-71-4 7439-93-2
rayovac_com---007125.asp 7439-89-6 12031-55-1 12031-65-1 12057-17-9 7782-42-5 7440-50-8 7429-90-5 7440-02-0 21324-40-3 96-49-1 623-53-0 616-38-6 105-58-8 79-20-9
rayovac_com---007126.asp 1313-13-9 110-71-4 7782-42-5 33454-82-9 7439-93-2 108-32-7 03-01-2
rayovac_com---007127.asp 1313-13-9 7439-95-4 10034-81-8 10294-40-3 7440-44-0 14307-35-8
rayovac_com---007128.asp 7440-02-0 7439-89-6 7440-43-9 1310-58-3 1310-73-2 1310-65-2 7440-48-4 03-05-2
rayovac_com---007129.asp 7440-02-0 1310-58-3 7440-48-4 7439-96-5 7429-90-5 7440-66-6
rayovac_com---007130.asp 7439-92-1 7664-93-9 03-05-2
rayovac_com---007131.asp 7440-66-6 7439-89-6 7440-02-0 7440-50-8 7440-47-3 7782-42-5 1310-58-3 7439-97-6
resene_com_au---arm221h.asp 68410-23-1 1330-20-7 107-98-2 64742-95-6 90-72-2
resene_com_au---magnetic_magic.asp 13463-67-7 7732-18-5
resene_com_au---total_colour_industrial_tin.asp 1330-20-7
rhinolinings_com_au---tds_pp1195.asp N/A
ril_com---msdsremax1.asp N/A
ril_com---msds_cbfs.asp N/A
ril_com---msds_of_liquefied_petoleum_gas.asp 68476-85-7 74-98-6 106-97-8
ril_com---msds_propylene.asp 115-07-1
ril_com---msds_pvc_reon.asp 9002-86-2
ril_com---msds_relene.asp 9002-88-4 91-22-3
ril_com---msds_relene_ultra.asp 9002-88-4 91-22-3
roche-applied-science_com---03535614_msds.asp 49-89-1
roche-applied-science_com---1004646.asp 37691-11-5
roche-applied-science_com---1011375.asp N/A
roche-applied-science_com---1017128.asp 24365-47-7
roche-applied-science_com---1034731.asp N/A
roche-applied-science_com---104159.asp N/A
roche-applied-science_com---1051458.asp N/A
roche-applied-science_com---1059467.asp 1405-41-0
roche-applied-science_com---1062603.asp 56-81-5
roche-applied-science_com---106801.asp 133-92-6
roche-applied-science_com---107409.asp 50-07-7

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC