VALCO CINCINNATI CONSUMER PRODUCTS INC.
MATERIAL SAFETY DATA SHEET
MATERIAL NAME: BRAKE AND PIPE LINE SEALANT GRADE 760 (710XX333, 710XX771)
EMERGENCY TELEPHONE NO.: CALL INFOTRAC AT 1-800-535-5053
PRODUCT INFORMATION NO.: (513) 874-6550
DATE ISSUED: SEPTEMBER 2006
SECTION I 鈥? GENERAL INFORMATION
MANUFACTURER鈥橲 NAME: VALCO CINCINNATI
ADDRESS: 411 CIRCLE FREEWAY DRIVE, CINCINNATI, OHIO 45246
TRADE NAME & SYNONYMS: BRAKE AND PIPE LINE SEALANT
HEALTH (NFPA): 1 FLAMMABILITY (NFPA): 1 REACTIVITY (NFPA): 1
D.O.T.: NOT REGULATED
SHELF LIFE: 2 YEARS
SECTION II 鈥? HAZARDOUS INGREDIENTS/IDENTITY INFORMATION
INGREDIENTS CAS# OSHA PEL ACGIH TLV %
Diethylene Glycol Dimethacrylate 2358-84-1 N/E N/E 70-80
Hydroperoxides, peroxy initiator 801-15-9 N/E 50 ppm 1-5
Methoxyphenol 150-76-5 N/E 375 ppm 1-2
Polyglycol oleates, maleates 150-76-0 N/E N/E 7-28
Tetrahydroquinoline 635-46-1 N/E 350 ppm 1-2
Sodium Sulfimide (Saccharin) 810-7-2 N/E N/A 2-5
Polyphosphoric Acid (PPA) 8017-16-1 N/E 50 ppm <1%
SECTION III 鈥? PHYSICAL/CHEMICAL CHARACTERISTICS
Appearance: White Paste, Mild Odor Boiling Point: 200潞F Melting Point: N/A
Specific Gravity: (H2O = 1) 1.08 at 75潞F Vapor Pressure: (mm Hg.) 0.01 mm at 75潞F
Vapor Density: (AIR = 1) 8.6 Evaporation Rate: (Butyl Acetate = 1) N/A
Solubility in Water: Insoluble
SECTION IV 鈥? FIRE AND EXPLOSION HAZARD DATA
Flashpoint: (F/C) SETA CC, ASTM D3278 250潞F
Fire Extinguishing Media: Water, Carbon Dioxide, Sand, Foam
Special Fire Fighting Procedures: None
Unusual Fire Fighting Procedures: None
Hazardous Products of Combustion: None
SECTION V 鈥? REACTIVITY DATA
INCOMPATIBILITY (MATERIALS TO AVOID): STRONG OXIDIZERS OR ACIDS
STABILITY AND REACTIVITY: EXOTHERMIC REACTION DURING POLYMERIZATION
TOXICOLOGICAL INFORMATION:
SECTION 313 SUPPLIER NOTIFICATION: THIS PRODUCT CONTAINS THE FOLLOWING TOXIC CHEMICALS
SUBJECT TO THE REPORTING RE-QUIREMENTS
OF SECTION 313 OF THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT OF 1986 AND OF 40
CFR, PART 372:
COMPONENT: CUMENE HYDROPEROXYDE CAS #: 80-15-9 PERCENT: 2 - 5%
TOXIC SUBSTANCES CONTROL ACT (TSCA) STATUS: THE INGREDIENTS OF THIS PRODUCT ARE ON THE
TSCA INVENTORY
PAGE 1 OF 2
VALCO CINCINNATI CONSUMER PRODUCTS INC.
MATERIAL SAFETY DATA SHEET
MATERIAL NAME: BRAKE AND PIPE LINE SEALANT GRADE 760 (710XX333, 710XX771)
EMERGENCY TELEPHONE NO.: CALL INFOTRAC AT 1-800-535-5053
PRODUCT INFORMATION NO.: (513) 874-6550
DATE ISSUED: SEPTEMBER 2006
SECTION VI 鈥? HEALTH HAZARD DATA
ROUTES OF ENTRY: EYES, SKIN, INGESTION, INHALATION
SKIN: REPEATED CONTACT MAY CAUSE REDDENING OR FLAKING OF SKIN.
EYE: MAY CAUSE PAIN. MAY CAUSE SLIGHT TRANSIENT (TEMPORARY) IRRITATION WITH SLIGHT
TRANSIENT CORNEAL INJURY.
INHALATION: CAUSES IRRITATION OF THE NOSE, EYES AND UPPER RESPIRATORY TRACT
INGESTION: CAUSES IRRITATION OF THE MOUTH, THROAT AND DIGESTIVE TRACT
SIGNS AND SYMPTOMS OF EXPOSURE: SENSITIVE EYES, REDDENING OF SKIN, SHORTNESS OF BREATH OR
DIZZINESS
AGGRAVATION OF EXISTING CONDITIONS: PRE-EXISTING EYE OR SKIN AND RESPIRATORY DISORDERS MAY
BE AGGRAVATED BY EXPOSURE
EMERGENCY AND FIRST AID PROCEDURES:
EYES: FLUSH WITH WATER FOR 15 MINUTES. CALL A PHYSICIAN.
SKIN: WASH WITH WARM SOAPY WATER. REMOVE CONTAMINATED CLOTHING. IF IRRITATION OCCURS,
GET MEDICAL ATTENTION
INGESTION: DO NOT GIVE LIQUIDS IF VICTIM IS UNCONSCIOUS OR VERY DROWSY. DO NOT INDUCE
VOMITING, CALL A PHYSICIAN.
INHALATION: REMOVE TO FRESH AIR. TREAT SYMPTOMS. CALL A PHYSICIAN.
MEDICAL CONDITION: EXPOSURE MAY CAUSE MYOCARDIAL IRRITABILITY
SECTION VII 鈥? PRECAUTIONS FOR SAFE HANDLING AND USE
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: ALLOW TO CURE THEN SCRAPE UP
PUTTY AND PLACE IN CONTAINER SUIT-ABLE FOR DISPOSAL. AVOID BREATHING FUMES/SPRAY/MIST,
VENTILATE CONFINED SPACES. KEEP FROM WATER COURSES AND SEWERS. DISPOSE OF MATERIAL IN
ACCORDANCE WITH ALL LAWS, FEDERAL, STATE AND LOCAL.
WASTE DISPOSAL METHOD: DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL
REGULATIONS AT TIME OF DISPOSAL.
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: KEEP AWAY FROM FOODSTUFFS. WASH
THOROUGHLY AFTER USE. DO NOT EAT, DRINK, OR SMOKE WHILE USING. SAFETY SHOWER, EYE BATH, AND
WASHING FACILITIES SHOULD BE AVAILABLE.
SECTION VII 鈥? CONTROL MEASURES
RESPIRATORY PROTECTION: IF IT IS POSSIBLE TO GENERATE SIGNIFICANT LEVELS OF VAPORS OR MISTS, A
NIOSH APPROVED OR EQUIVALENT RESPIRATOR IS RECOMMENDED.
VENTILATION: GENERAL VENTILATION IS RECOMMENDED.
PROTECTIVE EQUIPMENT: USE IMPERMEABLE GLOVES AND CHEMICAL SPLASH GOGGLES WHEN ATTACHING
FEEDING EQUIPMENT OR DOING MAINTENANCE.
IF CLOTHING IS CONTAMINATED, REMOVE CLOTHING AND THOROUGHLY WASH THE AFFECTED AREA.
LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
SECTION IX 鈥? DISCLAIMER
TO THE BEST OF OUR KNOWLEDGE, THE INFORMATION CONTAINED HEREIN IS ACCURATE; OBTAINED FROM
SOURCES BELIEVED BY VALCO CINCINNATI, INC. TO BE ACCURATE. SINCE THE CONDITIONS AND METHODS
OF USE OF OUR PRODUCT ARE BEYOND OUR CONTROL, WE DISCLAIM ANY AND ALL LIABILITY ARISING OUT
OF THE IMPROPER USE OF THIS PRODUCT OR THE INFORMATION PROVIDED HEREWITH.
PAGE 2 OF 2
|