Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

124-38-9

File Name: orcbs_msu_edu---177.asp
                                                                                                                                      MATERIAL
Linde Gas LLC (216) 642-6600
LindeGAS,LLC (216) 642-6600
AGA Gas INC. SAFETY
P.O. Box 94737 WOODS BLVD
P.O. Box 94737
6055 ROCKSIDE DATA SHEET
Cleveland, Ohio 44101
Cleveland, Ohio 44101
P.O. BOX 94737
www.us.lindegas.com
www.us.lindegas.com
CLEVELAND, OH 44101-4737 No. 177

PRODUCT NAME CAS #
CO2 = 124-38-9
DryWash庐 Fluid
DOT I.D. No.:
UN 3163
TRADE NAME AND SYNONYMS
Liquefied Gas, N.0.S. (D.0.T.)
DOT Hazard Class:
Division 2.2
CHEMICAL NAME AND SYNONYMS

Formula
Trade Secret; Contains CO2
A Trade Secret Liquid Mixture. Contains Carbon Dioxide
ISSUE DATES AND REVISIONS Chemical Family:
Liquefied Gas Mixture
June 1998

HEALTH HAZARD DATA
TIME WEIGHTED AVERAGE EXPOSURE LIMIT
( For CO2) 5,000 Molar PPM; STEL = 30,000 Molar PPM (ACGIH 1998). 0SHA 1995 PEL (8 hr. TWA) =
5,000 Molar PPM.
SYMPTOMS OF EXPOSURE

Inhalation: Low concentrations (3-5) molar %) cause increased respiration and headache.
Eight to 15 molar % concentrations cause headache, nausea and vomiting which may lead to unconsciousness if not
moved to open air or given oxygen.
High concentrations cause rapid circulatory insufficiency leading to coma and death.
TOXICOLOGICAL PROPERTIES
Carbon dioxide is the most powerful cerebral vasodilator known. Inhaling large concentrations causes rapid circulatory
insufficiency leading to coma and death. Chronic, harmful effects are not known from repeated inhalation of low (3-5
molar %) concentrations.

This mixture is not listed in the IARC, NTP or by 0SHA as a carcinogen or potential carcinogen.

Persons in ill health where such illness would be aggravated by exposure to this mixture should not be allowed to work
with or handle this product.



RECOMMENDED FIRST AID TREATMENT

PROMPT MEDICAL ATTENTION IS MANDATORY IN ALL CASES OF OVEREXPOSURE T0 THIS MIXTURE.
RESCUE PERSONNEL SHOULD BE EQUIPPED WITH SELF-CONTAINED BREATHING APPARATUS.

Inhalation: Conscious persons should be assisted to an uncontaminated area and inhale fresh air. Quick removal from
the contaminated area is most important. Unconscious persons should be moved to an uncontaminated area, given
assisted respiration and supplemental oxygen. Assure that vomited material does not obstruct the airway by use of
positional drainage. Further treatment should be symptomatic and supportive.




Information contained in this material safety data sheet is offered without charge for use by technically qualified personnel at their discretion and
risk. All statements, technical information and recommendations contained herein are based on tests and data which we believe to be reliable, but
the accuracy or completeness thereof is not guaranteed and no warranty of any kind is made with respect thereto. This information is not intended
as a license to operate under or a recommendation to practice or infringe any patent of this Company or others covering any process, composition
of matter or use.
Since the Company shall have no control of the use of the product described herein, the Company assumes no liability for loss or damage incurred
from the proper or improper use of such product.
DryWash庐 Fluid

HAZARDOUS MIXTURES OF OTHER LIQUIDS, SOLIDS, OR GASES
Forms carbonic acid in the presence of water



PHYSICAL DATA
BOILING POINT LIQUID DENSITY AT BOILING POINT
Solid Density - 97.5 lb/ft3 (1562 kg/m3)
Sublimation point = -109.3掳F (-78.5掳C)
VAPOR PRESSURE GAS DENSITY AT 70掳F. 1 atm
@ 70掳F (21.1掳C) =856 psia (5900 kPa) .124 lb/ft3 (1.99 kg/m3)
SOLUBILITY IN WATER FREEZING POINT
\/ery soluble -69.8潞F (-56.6潞C) @ 75.1 psia (518 kPa)
EVAPORATION RATE SPECIFIC GRAVITY (AIR=1)
N/A (Gas) @70潞F (21.1潞C) = 1.65
For the mixture; Colorless gas with very slight aliphatic odor.
APPEARANCE AND ODOR




FIRE AND EXPLOSION HAZARD DATA
AUTO IGNITION TEMPERATURE
FLASH POINT (Method used) FLAMMABLE LIMITS % BY VOLUME (See Page 4)
N/A N/A N/A N/A
LE UEL
ELECTRICAL CLASSIFICATION
EXTINGUISHING MEDIA
Nonhazardous
Nonflammable, inert gas
SPECIAL FIRE FIGHTING PROCEDURES
None


UNUSUAL FIRE AND EXPLOSION HAZARDS
If cylinders are involved in a fire, safely relocate or keep cool with water spray.



REACTIVITY DATA
STABILITY CONDITIONS TO AVOID
Unstable None

Stable X
INCOMPATIBILITY (Materials to avoid) None

HAZARDOUS DECOMPOSITION PRODUCTS Carbon Monoxide

HAZARDOUS POLYMERIZATION CONDITIONS TO AVOID

May Occur
None
Will Not Occur X

SPILL OR LEAK PROCEDURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED

Evacuate all personnel from affected area. Use appropriate protective equipment. If leak is in user鈥檚 equipment, be
certain to purge piping with an inert gas prior to attempting repairs. If leak is in container or container valve, contact
your closest supplier location or call the emergency telephone number listed herein.


WASTE DISPOSAL METHOD
Do not attempt to dispose of waste or unused quantities. Return in the shipping container properly labeled, with any
valve outlet plugs or caps secured and valve protection cap in place to your supplier. For emergency disposal
assistance, contact your closest supplier location or call the emergency telephone number listed herein.

2
DryWash庐 Fluid
SPECIAL PROTECTION INFORMATION
Positive pressure air line with mask or self-contained breathing apparatus should be available for
RESPIRATORY PROTECTION
(Specify type)
emercency use.
VENTILATION LOCAL EXHAUST SPECIAL
N/A
To prevent accumulation above the TWA
See Local Exhaust MECHANICAL (Gen.) OTHER
N/A
N/A
PROTECTIVE GLOVES
Any material
EYE PROTECTION
Safety goggles or glasses
OTHER PROTECTIVE EQUIPMENT
Safety shoes

SPECIAL PRECAUTIONS*
SPECIAL LABELING INFORMATION

DOT Shipping Name: Liquified Gas, N.O.S. DOT Hazard Class: Division 2.2
DOT Shipping Label: Nonflammable Gas I.D. No. UN 3163
SPECIAL HANDLING RECOMMENDATIONS

Use only in well-ventilated areas. Valve protection caps must remain in place unless container is secured with valve
outlet piped to use point. Do not drag, slide, or roll cylinders. Use a suitable hand truck for cylinder movement. Use a
pressure reducing regulator when connecting cylinder to lower pressure (<1500 psig) piping or systems. Do not heat
cylinder by any means to increase the discharge rate of product from the cylinder. Use a check valve or trap in the
discharge line to prevent hazardous back flow into the cylinder.

For additional handling recommendations, consult Compressed Gas Associations鈥? Pamphlets P-1, G-6, G-6.1, and
G-6.2.



SPECIAL STORAGE RECOMMENDATIONS

Protect cylinders from physical damage. Store in cool, dry, well-ventilated area away from heavily trafficked areas and
emergency exits. Do not allow the temperature where cylinders are stored to exceed 125潞F (52潞C). Cylinders should be
stored upright and firmly secured to prevent falling or being knocked over. Full and empty cylinders should be
segregated. Use a 鈥渇irst in - first out鈥? inventory system to prevent full cylinders being stored for excessive periods of
time.

For additional storage recommendations, consult Compressed Gas Association鈥檚 Pamphlets P-1, G-6, G-6.1, and
G-6.2.



SPECIAL PACKAGING RECOMMENDATIONS
Dry carbon dioxide can be handled with most common structural materials. Moist carbon dioxide is corrosive by its
formation of carbonic acid. For these applications, 316, 309 and 310 stainless steels may be used as well as
Hastelloy庐 A, B and C and Monel庐. Ferrous nickel alloys are slightly corroded.

At normal temperatures carbon dioxide is compatible with most plastics and elastomers.



OTHER RECOMMENDATIONS OR PRECAUTIONS
Compressed gas cylinders should not be refilled except by qualified producers of compressed gases. Shipment of a
compressed gas cylinder which has not been filled by the owner or with his (written) consent is a violation of Federal
Law (49CFR).

(Continued on Page 4)


*Various Government Agencies (i.e. Department of Transportation, Occupational Safety and Health Administration, Food and Drug Administration
3
and others) may have specific regulations concerning the transportation, handling, storage or use of this product which will not be reflected in this
data sheet. The customer should review these regulations to ensure that he is in full compliance.
DryWash庐 Fluid Page 4

SPECIAL PRECAUTIONS

OTHER RECOMMENDATIONS OR PRECAUTIONS: (Continued)


Always secure cylinders in an upright position before transporting them. NEVER transport cylinders in trunks of vehicles,
enclosed vans, truck cabs or in passenger compartments. Transport cylinders secured in open flatbed or in open pick-up
type vehicles.

Reporting under SARA, Title III, Section 313 not required.

NFPA 704 No. for this mixture = 2 O O None




4

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
orcbs_msu_edu---144.asp 593-53-3
orcbs_msu_edu---145.asp 7727-37-9 2551-62-4
orcbs_msu_edu---146.asp 8006-14-2 74-82-8
orcbs_msu_edu---147.asp 7440-01-9
orcbs_msu_edu---148.asp 7783-54-2
orcbs_msu_edu---149.asp 75-56-9
orcbs_msu_edu---150.asp 7803-62-5
orcbs_msu_edu---151.asp 7783-60-0
orcbs_msu_edu---152.asp 10025-78-2
orcbs_msu_edu---153.asp 121-44-8
orcbs_msu_edu---154.asp 7783-82-6
orcbs_msu_edu---156.asp 107-25-5
orcbs_msu_edu---158.asp 1333-74-0
orcbs_msu_edu---159.asp 7782-44-7
orcbs_msu_edu---160.asp N/A
orcbs_msu_edu---161.asp 1333-74-0
orcbs_msu_edu---162.asp 7727-37-9
orcbs_msu_edu---165.asp 124-38-9 7727-37-9
orcbs_msu_edu---166.asp 10102-43-9 7440-37-1
orcbs_msu_edu---168.asp 7782-42-7 7727-37-9
orcbs_msu_edu---169.asp 7782-42-7 7440-59-7
orcbs_msu_edu---170.asp 7782-42-7 7440-59-7
orcbs_msu_edu---171.asp 7440-59-7 7440-37-1
orcbs_msu_edu---172.asp 7440-59-7
orcbs_msu_edu---173.asp 7782-44-7
orcbs_msu_edu---174.asp 133-74-0 7440-37-1
orcbs_msu_edu---176.asp 74-98-6
orcbs_msu_edu---177.asp 124-38-9
orcbs_msu_edu---178.asp 10102-43-9 7727-37-9
orcbs_msu_edu---180.asp N/A
orcbs_msu_edu---182.asp 7727-37-9 630-08-0
orcbs_msu_edu---183.asp 7446-09-5 10102-43-9
orcbs_msu_edu---184.asp 10026-04-7
orcbs_msu_edu---186.asp 10102-43-9 7440-59-7
orcbs_msu_edu---188.asp 7440-59-7
orcbs_msu_edu---189.asp 10102-43-9 7440-37-1
pennzoil-quakerstate_com---014978.asp 107-21-1 111-46-6 7732-18-5
pennzoil-quakerstate_com---015123.asp 64742-57-0 64742-54-7 64742-52-5 64742-65-0
pennzoil-quakerstate_com---016034.asp N/A
pennzoil-quakerstate_com---024403.asp 9003-29-6
pgbrands_com---3_1_2_3b_CarpetExtraction-UsingBonnetCleanerProduct.asp N/A
pgbrands_com---AUTO-DISH_DELIMER_130440_newansi_english_msds.asp 7664-38-2
pgbrands_com---AutoDishSanitizer.130350.newansi.english.msds.asp 7681-52-9 7647-14-5
pgbrands_com---Bounce_-_All_Varieties_Except_FREE.asp N/A
pgbrands_com---Cascade_Dishwasher_Detergent_Powder_031706_MSDS_eng.asp 497-19-8 7632-04-4 1344-09-8
pgbrands_com---Clean_Quick_Broad_Range_Sanitizer_12-06.asp 64-17-5
pgbrands_com---Clean_Quick_Chlorinated_Sanitizer_and_Cleaner_0900_MSDS.asp 2893-78-9
pgbrands_com---Clean_Quick_Chlorine_Sanitizer_0801_MSDS.asp 2893-78-9
pgbrands_com---Comet_Creme_Cleanser_MSDS_eng.asp 497-19-8 93763-70-3 7681-52-9
pgbrands_com---Comet_Disinfecting_Bathroom_Cleaner_MSDS_1007_eng.asp N/A

Free MSDS Search ( Providing 250,000+ Material Properties )