Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

008003-34-7
000051-03-6
000124-38-9

File Name: indfumco_com---Turbocide_II_wPyrocide_MSDS_7.18.07.asp
                                                                                                        Page 1 of 6


MATERIAL SAFETY DATA SHEET
Date-Issued: 08/06/2004
#67
MSDS Ref. No:
Date-Revised: 12/15/2004
Revision No: New MSDS

TurboCide庐 II Pest Control System with PYROCIDE庐

1. PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NAME: TurboCide庐 II Pest Control System
PRODUCT DESCRIPTION: A Pressurized Aerosol Insecticide
PRODUCT CODE: #67, EPA REG. NO. : 1021-1821-47000

MANUFACTURER 24 HR. EMERGENCY TELEPHONE NUMBERS

Chem-Tech, Ltd CHEMTREC U.S. and CANADA: (800) 424-9300
4515 Fleur Dr. #303 CHEMTREC All Other Areas: (703) 527-3887
Des Moines, IA 50321 Emergency Phone: (888) 740-8712
Product Stewardship: Industrial Fumigant Co.
Customer Service: (913) 782-7600

COMMENTS: IFC Hours of operation are 8:00 am to 4:30 pm CST, 14:00 to 22:30 GMT.

For information regarding MEDICAL EMERGENCIES or PESTICIDE INCIDENTS, call the INTERNATIONAL
POISON CENTER 24 hours a day at 1-888-740-8712 .

2. COMPOSITION / INFORMATION ON INGREDIENTS

Chemical Name Wt.% CAS# EINECS #
Pyrethrins 0.5 008003-34-7 232-319-8
Piperonyl Butoxide 4 000051-03-6 200-076-7
Petroleum Distillates <10 64742 -47-8 265-149-8
Carbon Dioxide 75 - 90 000124-38-9 Not Avail.

COMMENTS: Ingredients not identified are proprietary or non-hazardous. Values are not product specifications.

3. HAZARDS IDENTIFICATION

EMERGENCY OVERVIEW
IMMEDIATE CONCERNS: CAUTION. Contents under pressure. Keep away from heat, sparks, open flame,
and any other ignition sources. Do not expose to temperatures above 130掳F (54.4掳C) as bursting may occur.
Harmful if swallowed. Contains petroleum distillates; Vomiting may pose an aspiration pneumonia hazard.
Avoid contact with skin, eyes, and clothing. Avoid breathing vapors or spray mists of this product.

DO NOT puncture or incinerate container.

POTENTIAL HEALTH EFFECTS
EYES: May cause eye irritation.
SKIN: Can cause skin irritation. Can cause a burning or prickling sensation on more sensitive areas (face,
eyes, mouth).
SKIN ABSORPTION: May be harmful if absorbed through the skin.
INGESTION: Harmful if swallowed. Small amounts of this product aspirated into the respiratory system during
ingestion or vomiting may cause mild to severe lung injury.
INHALATION: Excessive inhalation of mists can cause nasal and respiratory irritation.
TurboCide庐 II Pest Control System with PYROCIDE庐 Page 2 of 6


CHRONIC: None known.

4. FIRST AID MEASURES

EYES: Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if
present, after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for treatment
advice.

SKIN: Take off contaminated clothing. Rinse skin immediately with plenty of water for 15-20 minutes. Call a
poison control center or doctor for treatment advice.

INGESTION: If swallowed, IMMEDIATELY call a poison control center or doctor for treatment advice. DO NOT
give any liquid to the person. Do not induce vomiting unless told to do so by a poison contol center or a doctor.
Never give anything by mouth to an unconscious person.

INHALATION: Remove affected person to fresh air. If person is not breathing, call 911 or an ambulance, then
give artificial respiration, preferably mouth-to-mouth if possible. Call a poison control center or doctor for further
treatment advice.

NOTES TO PHYSICIAN: Contains Pyrethrins and Petroleum Distillates-vomiting may pose an aspiration
pneumonia hazard.
For skin effects, a highly efficient therapeutic agent for Pyrethrin exposure is topical application of Tocopherol
Acetate (Vitamin E).

5. FIRE FIGHTING MEASURES

FLAMMABLE CLASS: This aerosol is estimated to be NON-FLAMMABLE based on the materials in the
formulation.

EXTINGUISHING MEDIA: Foam, carbon dioxide or dry chemical.

HAZARDOUS COMBUSTION PRODUCTS: This product is classified as Non-Combustible, however in the
exteme temperatures that fires may produce, some of the constituents of this formula may decompose to give
off such gases as carbon dioxide, carbon monoxide, and nitrogen oxides.

EXPLOSION HAZARDS: Contents under pressure. Exposure to temperatures above 130掳F / 54.4掳C may cause
bursting.

FIRE FIGHTING PROCEDURES: Treat as an oil fire. Use a full-faced self-contained breathing apparatus along
with full protective gear. Keep nearby containers and equipment cool with a water stream.

SENSITIVITY TO IMPACT: Forceful impacts can cause damage to aerosol unit and may cause a bursting or
explosion hazard.

6. ACCIDENTAL RELEASE MEASURES

SMALL SPILL: Stop release, if possible without risk. Dike or contain release, if possible, and if immediate
response can prevent further damage or danger. Isolate and control access to the release area. Take actions to
reduce vapors. Absorb with appropriate absorbent such as sand, or vermiculite. Clean spill area of residues
and absorbent.

LARGE SPILL: Stop release, if possible without risk. Dike or contain release, if possible, and if immediate
response can prevent further damage or danger. Isolate and control access to the release area. Take actions to
reduce vapors. Collect product into drums, storage tanks, etc., via drains, pumps, etc. Absorb with appropriate
absorbent such as sand or vermiculite. Clean spill area of residues and absorbent.

ENVIRONMENTAL PRECAUTIONS
WATER SPILL: Contains Pyrethrins, which are toxic to fish and other aquatic invertebrates. Contaminated
absorbent and wash water should be disposed of according to local, state, and federal regulations.
TurboCide庐 II Pest Control System with PYROCIDE庐 Page 3 of 6


7. HANDLING AND STORAGE

GENERAL PROCEDURES: Do not use near heat, open flame, or any other ignition source.

HANDLING: Contents under pressure. Do not pucture or incinerate. Do not use near heat,sparks, open flame, or
any other ignition sources. Do not remain in the building during treatment. Ventilate thoroughly for 30 minute's
before reoccupying treated area. Avoid breathing vapor or spray mists. Do not contaminate water, feed or food
by storage, handling or disposal.

READ AND OBSERVE ALL PRECAUTIONS AND INSTRUCTIONS ON THE LABEL.

STORAGE: This cylinder must be checked periodically. A defective cylinder should not be used. A cylinder that
has parts missing, is plainly worn or distorted should be replaced immediately.

Store in a cool, dry, well-ventilated, preferably locked storage area. Exposure to temperatures above 130掳F /
54.4掳C may cause bursting. Store containers upright and closed. Keep away from heat, ignition sources, and
strong oxidizers. Emptied containers may retain product residues.

KEEP OUT OF REACH OF CHILDREN

8. EXPOSURE CONTROLS / PERSONAL PROTECTION

EXPOSURE GUIDELINES:
OSHA HAZARDOUS COMPONENTS (29 CFR 1910.1200)
EXPOSURE LIMITS
OSHA PEL ACGIH TLV Supplier OEL
3 ppm mg/m3 ppm mg/m3
ppm mg/m
Pyrethrins TWA 5 5
Piperonyl Butoxide TWA None None None
Petroleum Distillates TWA None None 200 100 525
Carbon Dioxide TWA 5000 9000 5000 9000
STEL 30000 3000 5400

ENGINEERING CONTROLS: Ventilate treatment area thoroughly before re-entry.

PERSONAL PROTECTIVE EQUIPMENT
EYES AND FACE: Take prudent precautions to avoid contact with eyes.
SKIN: Take prudent precautions to avoid contact with skin and clothing.
RESPIRATORY: Wearing a respirator is not normally required when handling this product. Use in well
ventilated areas. Take prudent precautions to avoid breathing vapors and/ or spray mists of this product.

WORK HYGIENIC PRACTICES: DO NOT SMOKE, EAT, OR DRINK, OR APPLY COSMETICS IN WORK
AREA!
Wash promptly if skin becomes contaminated. Wash at the end of each work shift and before eating, smoking,
or using the toilet.

9. PHYSICAL AND CHEMICAL PROPERTIES

PHYSICAL STATE: Liquefied gases and liquid.
ODOR: Slight odor of petroleum distillates.
pH: Not Available
VAPOR PRESSURE: Not Available
VAPOR DENSITY: 8.54 (Air=1)
BOILING POINT: Not Available
TurboCide庐 II Pest Control System with PYROCIDE庐 Page 4 of 6


FREEZING POINT: Not Available
MELTING POINT: Not Available
SOLUBILITY IN WATER: Not Determined
EVAPORATION RATE: Not Available
DENSITY: Not Available
SPECIFIC GRAVITY: 1.02 (Water = 1) Hydrometer @ 20掳C (68掳F)
VISCOSITY: Not Available
COMMENTS:
VAPOR DENSITY: Vapor Density measurement is for the aerosol contents less the compressed gas
propellent (i.e., Non-Volatiles).
SPECIFIC GRAVITY: Specific Gravity is for the aerosol contents less the compressed gas propellent (i.e.,
Non-Volatiles).


10. STABILITY AND REACTIVITY

STABLE: YES

HAZARDOUS POLYMERIZATION: NO

CONDITIONS TO AVOID: Not compatible with strong acids or bases. Not compatible with strong oxidizers.

11. TOXICOLOGICAL INFORMATION

ACUTE
Acute toxicological data not available.

COMMENTS: None of the components present in this material at concentrations equal to or greater than
0.1% are listed by IARC, NTP, OSHA or ACGIH as being carcinogens.

Carcinogenicity/ Oncogenicity-Pyrethrum has been tested in chronic feeding studies in mice and rats.
Slightly elevated incidences of benign tumors of the thyroid and liver were seen in rats following high
doses of Pyrethrum. Further detailed scientific studies into the mechanism causing these responses
indicate that these effects in the animals only occur at doses greatly exceeding the likely human
exposure levels. Thus, the effects seen in animals are of little relevance to humans.

Marginally higher incidences of benign liver tumors in mice were observed following lifetime high dose
exposures to PBO. The significance of these observations is questionable and under review. The doses
at which tumors were observed for PBO greatly exceeded potential human exposure from labeled uses.
Doses at which these effects were observed greatly exceed anticipated human dietary intake. At
anticipated dietary exposure levels, it is highly unlikely that this product will result in carcinogenic
effects.

12. ECOLOGICAL INFORMATION

ENVIRONMENTAL DATA: Environmental data not available for this product.

ECOTOXICOLOGICAL INFORMATION: This product is toxic to fish. Do not apply where runoff is likely to occur.
Do not apply when weather conditions favor drift from areas treated. Do not contaminate water when disposing
of washwaters. Shrimp and crabs may be killed at application rates recommended on this label. Do not apply
where these are important resources.

13. DISPOSAL CONSIDERATIONS

DISPOSAL METHOD: Pesticide that cannot be used according to label directions must be returned to the point
of purchase in its' original container.
TurboCide庐 II Pest Control System with PYROCIDE庐 Page 5 of 6


EMPTY CONTAINER: Cylinders must not be disposed of in any manner. Cylinders must be returned to supplier
or point of purchase for credit. All cylinders, valves and caps remain the property of the manufacturer. Federal
regulations prohibit the refilling of cylinders without written consent of the manufacturer.

RCRA/EPA WASTE INFORMATION: This product contains the following RCRA/CERCLA Hazardous
wastes/substances:

Component, RCRA ID#, Cercla RQ

Pyrethrins, N/A, 1 Lb.

14. TRANSPORT INFORMATION

DOT (DEPARTMENT OF TRANSPORTATION)
PROPER SHIPPING NAME: Insecticide Gases, N.O.S. (Carbon Dioxide, Pyrethrins)
PRIMARY HAZARD CLASS/DIVISION: 2.2
UN/NA NUMBER: UN1968

AIR (ICAO/IATA)
PROPER SHIPPING NAME: Insecticide Gases, N.O.S. (Carbon Dioxide, Pyrethrins)
PRIMARY HAZARD CLASS/DIVISION: 2.2
UN/NA NUMBER: UN1968

VESSEL (IMO/IMDG)
PROPER SHIPPING NAME: Not Available

15. REGULATORY INFORMATION

UNITED STATES
SARA TITLE III (SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT)
311/312 HAZARD CATEGORIES:
FIRE: NO PRESSURE GENERATING: YES REACTIVITY: NO ACUTE: YES
313 REPORTABLE INGREDIENTS:
COMPONENT, CAS#, Max %

Piperonyl Butoxide, 000051-03-6, 4.00
302/304 EMERGENCY PLANNING
EMERGENCY PLAN: There are no SARA Title III Section 302 extremely hazardous substances present
in this formulation. (40 CFR 355).

See Section 13 of this MSDS for the components that are subject to emergency requirements under
CERCLA Section 103(a)(40 CFR 302.4).
TSCA (TOXIC SUBSTANCE CONTROL ACT)
TSCA STATUS: All chemical substances found in this product comply with the Toxic Substances Control
Act's inventory reporting requirements.

16. OTHER INFORMATION

REVISION SUMMARY New MSDS
TurboCide庐 II Pest Control System with PYROCIDE庐 Page 6 of 6


HMIS RATING

1
HEALTH:

1
FLAMMABILITY:

1
PHYSICAL HAZARD:

PERSONAL PROTECTION:


HMIS RATINGS NOTES: We assign HMIS ratings to this product based on the hazards of its ingredients(s).
Since the customer is most aware of the applications and conditions of use, he or she must ensure that the
proper Personal Protective Equipment is provided, consistent with the information contained in Section's 7 and
8 of this MSDS.

COMMENTS: The data contained herein is based on information currently available to the Manufacturer, and
believed to be factual and the opinions expressed to be those of qualified experts; however, this data is not to
be taken as a warranty or representation for which the Manufacturer assumes legal
responsibility.

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
indfumco_com---Trapper_Glue_Boards_MSDS_6.22.05.asp N/A
indfumco_com---Trapper_Max_MSDS_3.29.05.asp N/A
indfumco_com---Trece_Lures_MSDS_5.13.05.asp N/A
indfumco_com---Trece_Trap_Glue_MSDS_8.17.05.asp N/A
indfumco_com---TRI-DIE_MSDS_10.17.06.asp N/A
indfumco_com---Turbocide_Gold_II_wPyrocide__MSDS_7.18.07.asp 008003-34-7 000051-03-6 000112-34-5
indfumco_com---Turbocide_II_wPyrocide_MSDS_7.18.07.asp 008003-34-7 000051-03-6 000124-38-9
indfumco_com---ULD_BP-100_MSDS.asp N/A
indfumco_com---ULD_BP-100_Plus_MSDS_6.22.05.asp N/A
indfumco_com---ULD_BP-300_Contact_Insecticide_MSDS_7.17.07.asp N/A
indfumco_com---Vangrip_MSDS_8.18.05.asp N/A
indfumco_com---Vap-20_CO2_MSDS_8.18.05.asp N/A
indfumco_com---Vap-5_MSDS_7.18.07.asp N/A
indfumco_com---Vapo-Cide_MSDS_7.2.07.asp N/A
indfumco_com---Vector_Bio-5_MSDS_8.18.05.asp N/A
indfumco_com---Vector_Nova_Supernova_with_Pher_MSDS_3.27.06.asp N/A
indfumco_com---Xlure_Combo-4_MSDS_10.2.06.asp N/A
indfumco_com---Xlure_RTU_Inspector_MSDS_3.27.06.asp N/A
indfumco_com---ZP_Rodent_Bait_MSDS.asp N/A
indfumco_com---ZP_Tracking_Powder_MSDS_9.20.04.asp N/A
jm_com---EN1001_CFr.asp 65997-17-3 1333-86-4
jm_com---EN1004_CFr.asp 65997-17-3
jm_com---EN1009_CFr.asp 65997-17-3 25038-59-9 25637-99-4 1333-86-4 1309-64-4
jm_com---EN1012.asp N/A
jm_com---EN1013_CFr.asp 65997-17-3 9011-05-6 471-34-1 50-00-0
jm_com---EN1014.asp 55918-56-4 9011-05-6 1333-86-4 50-00-0
jm_com---EN1021_CFr.asp 65997-17-3 1309-64-4
jm_com---EN1025.asp 65997-17-3 7429-90-5 1309-64-4
jm_com---EN1027.asp 8052-42-4 7429-90-5 65997-17-3 1309-64-4
jm_com---EN1035.asp 7732-18-5
jm_com---EN1041.asp 1333-86-4
jm_com---EN1042.asp 65997-17-3 100-97-0 1333-86-4 7664-41-7 50-00-0 108-95-2
jm_com---EN1056.asp 1309-64-4
jm_com---EN1064.asp N/A
jm_com---EN1075.asp N/A
jm_com---EN1105.asp 65997-17-3
jm_com---EN1121.asp N/A
jm_com---EN2055.asp 7732-18-5 1317-65-3 21645-51-2 1309-42-8 1309-64-4 68610-51-5 148-79-8 14808-60-7
jm_com---EN2402.asp 55918-56-4
jm_com---EN3012_CFr.asp 65997-17-3 78-78-4 287-92-3
jm_com---EN3106_Cfr.asp 108-88-3 67-64-1 142-82-5 110-54-3 64742-89-8 110-82-7 100-41-4 50-00-0
jm_com---EN3112.asp 65997-17-3 64742-93-4 25104-55-6 9003-07-0
jm_com---EN3129_Spanish.asp 1317-65-3 1333-86-4 63231-67-4 1305-78-8 64742-52-5 69102-90-5 7631-86-9 13463-67-7 14808-60-7
jm_com---EN3149_Cfr.asp 1330-20-7 100-41-4 108-88-3 71-43-2
jm_com---EN3152_Cfr.asp 1330-20-7 100-41-4 8052-41-3 13463-67-7 108-88-3
jm_com---EN3201_Spanish.asp N/A
jm_com---EN3204_Spanish.asp 141-78-6 75-07-0
jm_com---EN3206_Spanish.asp 109-99-9 108-94-1
jm_com---EN3208_Spanish.asp 13463-67-7 1317-65-3 1330-20-7 100-41-4 101-68-8 1333-86-4
jm_com---EN3225.asp 1317-65-3 1305-78-8

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC