Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

N/A

File Name: jm_com---EN1012.asp
                                         Material Name: Fiber Glass Chopped Strand                                   Safety Data Sheet
ID: 1012

Section 1 - Product and Company Identification
Hazard Label CAUTION label
Company Information
Johns Manville Engineered Products Group Telephone: 303-978-2000 8:00AM-5:00PM M-F
Mats and Reinforcements Division Internet Address: http://www.jm.com
P.O. Box 5108 Emergency: 800-424-9300 (Chemtrec, in English)
Denver, CO 80127 USA

Trade Names: 700 Star Stran Series; 700 ThermoFlow庐 Series

Use: Reinforcements for use in various applications.
Section 2 - Hazards Identification
Summary
Breathing dust from this product may cause a scratchy throat, congestion, and slight coughing. Getting dust or fibers on the
skin, or in the eyes may cause itching, rash, or redness. Additional health and safety information is provided in Section 11 of
this safety data sheet.
Inhalation
Irritation of the upper respiratory tract (scratchy throat), coughing, and congestion may occur in extreme exposures.
Skin
Temporary irritation (itching) or redness may occur.
Ingestion
This product is not intended to be ingested (eaten). If ingested, it may cause temporary irritation to the gastrointestinal
(digestive) tract.
Eyes
Temporary irritation (itching) or redness may occur.
Ears
Temporary irritation (itching) or redness may occur.
Primary Routes of Entry (Exposure)
Eyes, skin, inhalation (breathing dust and fibers) and ingestion.
Target Organs
Nose (nasal passages), throat, lungs, skin, eyes
Medical Conditions Aggravated by Exposure
Pre-existing chronic respiratory, skin, or eye diseases or conditions.
Section 3 - Composition/Information on Ingredients
CAS # Component Percent
Not Available Continuous filament glass fibers 97-99
Not Available Sizing <1

Component Information
Filament (fiber) average diameters are > 10 microns.

Sizing is a chemical mixture applied to the glass strands. Sizing is less than 1% of the finished product by weight and is a
mixture of polymers and small amounts of other additives.
General Product Description
White glass fibers in chopped form. No significant odor.
Section 4 - First Aid Measures
First Aid: Inhalation
If dust is inhaled in excess of exposure limits referenced in section 8 of this safety data sheet, remove individual to fresh air.
Drink water to clear throat, and blow nose to remove dust. A saline spray in the nose may help clear any fibers.
First Aid: Skin
Wash gently with soap and water to remove dust and fibers. Alternatively, fibers can be removed from the skin by use of
ordinary masking or wrapping tape. Should irritation persist, seek medical attention.


____________________________________________________________
Page 1 of 5 Issue Date: 03/07/2008 Revision: 1.0006
Material Name: Fiber Glass Chopped Strand Safety Data Sheet
ID: 1012

First Aid: Ingestion
Rinse mouth with water to remove dust and fibers and drink plenty of water to help reduce irritation. If irritation persists, seek
medical attention.
First Aid: Eyes
Do not rub or scratch eyes. Dust particles may cause the eye to be scratched. Flush eyes with large amounts of water until
irritation subsides. If irritation persists, seek medical attention.
First Aid: Ears
Wash exposed skin with soap and water. If irritation develops in the inner ear, seek medical attention.
First Aid: Notes to Physician
Dust from the product may cause mechanical irritation of the eyes, skin, and upper respiratory tract. Treat symptomatically.
Section 5 - Fire Fighting Measures
Flash Point: Not applicable Method Used: Not applicable
Upper Flammable Limit (UFL): Not applicable Lower Flammable Limit (LFL): Not applicable
Auto Ignition: Not determined Flammability Classification: Not determined
Rate of Burning: Not determined
General Fire Hazards
There is no potential for spontaneous fire or explosion. Inorganic glass fibers are naturally non-combustible and non-
flammable.
Extinguishing Media
Carbon dioxide (CO2), water, water fog, dry chemical.
Fire Fighting Equipment/Instructions
No special procedures are expected to be necessary for this product. Normal fire fighting procedures should be followed to
avoid inhalation of smoke and gases.
Section 6 - Accidental Release Measures
Clean-Up Procedures
Pick up large pieces. Vacuum dusts. If sweeping is necessary, use a dust suppressant such as water. Do not dry sweep dust
accumulation. These procedures will help to minimize potential exposures.
Section 7 - Handling and Storage
Handling Procedures
Use protective equipment as described in Section 8 of this safety data sheet when handling uncontained material. Handle in
accordance with good industrial hygiene and safety practices.
Storage Procedures
Warehouse storage should be in accordance with package directions, if any. Material should be kept clean, dry, and in original
packaging.
Section 8 - Exposure Controls / Personal Protection
The Occupational Safety and Health Administration (OSHA) has not adopted specific occupational exposure standards for
fiber glass. Fiber glass is treated as a nuisance dust and is regulated by OSHA as a particulate not otherwise regulated (total
dust) shown in CFR 1910.1000 Table Z-3.
Respirable fraction 5 mg/m3
Total dust 15 mg/m3

JM has adopted the fiber glass industry voluntary Product Stewardship Program (PSP), formerly the NAIMA-OSHA Health and
Safety Partnership Program (HSPP). Under the PSP, JM recommends that exposures be limited to the voluntary concentration
of 1 f/cc TWA for fibers longer than 5 microns with a diameter less than 3 microns. This will help minimize potential irritation
effects. The PSP also includes the PPE recommendations described below.

PERSONAL PROTECTIVE EQUIPMENT
Personal Protective Equipment: Eyes/Face
Safety glasses with side shields are recommended to keep dust out of the eyes.
Personal Protective Equipment: Ears
Use ear protection (earplugs, hood, or earmuffs) to prevent airborne dust or fibers from entering the ear, if necessary.



____________________________________________________________
Page 2 of 5 Issue Date: 03/07/2008 Revision: 1.0006
Material Name: Fiber Glass Chopped Strand Safety Data Sheet
ID: 1012

Personal Protective Equipment: Skin
Leather or cotton gloves should be worn to protect against mechanical abrasion. See also Personal Protective Equipment:
General, below.
Personal Protective Equipment: Respiratory
A respirator should be used if ventilation is unavailable, or is inadequate for keeping dust and fiber levels below the applicable
exposure limits referenced in Section 8 of this SDS. Wear a NIOSH-certified disposable or reusable particulate respirator with
an efficiency rating of N95 or higher (per 42 CFR 84) when dust or fiber concentrations exceed the applicable exposure limits.
Operations such as sawing, blowing, tear out, and spraying may generate airborne fiber concentrations requiring a higher level
of respiratory protection. For exposures up to 50 times the established exposure limits use a full-face respirator, rated N99 or
higher.
Ventilation
In fixed manufacturing settings, local exhaust ventilation should be provided at areas of cutting to remove airborne dust and
fibers. General dilution ventilation should be provided as necessary to keep airborne dust and fibers below the applicable
exposure limits and guidelines. The need for ventilation systems should be evaluated by a professional industrial hygienist,
while the design of specific ventilation systems should be conducted by a professional engineer.
Personal Protective Equipment: General
Protective equipment should be provided as necessary to prevent irritation of the throat, eyes, and skin, and to keep
exposures below the applicable exposure limits identified in Section 8.

Section 9 - Physical & Chemical Properties
Appearance: Odor:
White glass fibers in chopped form No significant odor
Physical State: pH:
Solid Not applicable
Vapor Pressure: Vapor Density:
Not applicable Not applicable
Boiling Point: Melting Point:
Not applicable >871潞C/1600潞F
Solubility (H2O): Specific Gravity:
Nil 2.54 g/cm
Freezing Point: Softening Point:
Not applicable 845潞C/1553潞F
Evaporation Rate: Percent Volatile:
Not applicable 0
VOC: Not determined

Section 10 - Stability & Reactivity Information
Stability
These products are not reactive.
Hazardous Decomposition
May form carbon dioxide and carbon monoxide.
Hazardous Polymerization
Will not occur.
Section 11 - Toxicological Information
Acute Toxicity
A: General Product Information
If dust evolves from this product during use it may cause temporary mechanical irritation or scratchiness of the throat and/or
itching of the eyes and skin.
B: Component Analysis - LD50/LC50
No LD50/LC50's are available for this product's components.
Component Carcinogenicity
Continuous filament glass fibers (Not Available)
ACGIH: A4 - Not Classifiable as a Human Carcinogen
IARC: Group 3 - Not Classifiable (IARC Monograph 81 [2002] (listed under Man-made mineral fibres),
Monograph 43 [1988])




____________________________________________________________
Page 3 of 5 Issue Date: 03/07/2008 Revision: 1.0006
Material Name: Fiber Glass Chopped Strand Safety Data Sheet
ID: 1012

Chronic Toxicity
Continuous Filament Glass Fiber: No chronic health effects are known to be associated with exposure to continuous filament
fiber glass. Results from epidemiologic studies have not shown any increases in respiratory disease or cancer. The
International Agency for Research on Cancer (IARC) has classified continuous filament fiber glass as a Group 3 substance,
not classifiable as to its carcinogenicity to humans. Because of the large diameter of continuous filament fibers, these products
are not considered respirable.
Section 12 - Ecological Information
Ecotoxicity
A: General Product Information
Not expected to be dangerous to the environment.
B: Component Analysis - Ecotoxicity - Aquatic Toxicity
No ecotoxicity data are available for this product's components.
Section 13 - Disposal Considerations
US EPA Waste Number & Descriptions
A: General Product Information
This product is not expected to be a hazardous waste when it is disposed of according to the U.S. Environmental Protection
Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. Product characterization after use is
recommended to ensure proper disposal under federal and/or state requirements.
B: Component Waste Numbers
No EPA Waste Numbers are applicable for this product's components.
Disposal Instructions
Dispose of waste material according to Local, State, Federal, and Provincial Environmental Regulations.
Section 14 - Transport Information
International Transport Regulations
These products are not classified as dangerous goods according to international transport regulations.
Section 15 - Regulatory Information
US Federal Regulations
A: General Product Information
SARA 311/312: This product is not classified as hazardous under SARA 311/312.
B: Component Analysis
None of this products components are listed under SARA Section 302 (40 CFR 355 Appendix A), SARA Section 313 (40 CFR
372.65), or CERCLA (40 CFR 302.4).
State Regulations
General Product Information
The glass fibers in this product are not known to be regulated.

Other state regulations may apply. Check individual state requirements.
TSCA Status
This product and its components are listed on the TSCA 8(b) inventory.

None of the components listed in this product are listed on the TSCA Export Notification 12(b) list.
International Regulations
A: General Product Information
These products are considered articles under both U.S. and international product regulations and as such, these products do
not require registration or notification on the various country-specific inventories.
B: Component Analysis - WHMIS IDL
The following components are identified under the Canadian Hazardous Products Act Ingredient Disclosure List:
Component CAS # Minimum Concentration
Continuous filament glass fibers Not Available 1 % (related to Fibrous glass)

WHMIS Classification
This is not a WHMIS controlled product. This product has been classified in accordance with the hazard criteria of the
Controlled Products Regulations. This SDS contains all the information required by the Controlled Products Regulations.


____________________________________________________________
Page 4 of 5 Issue Date: 03/07/2008 Revision: 1.0006
Material Name: Fiber Glass Chopped Strand Safety Data Sheet
ID: 1012

Section 16 - Other Information
Other Information
Prepared for:
Johns Manville Engineered Products Group
Mats & Reinforcements Division
P.O. Box 5108
Denver, CO 80217-5108

Prepared by:
Johns Manville Technical Center
P.O. Box 625005
Littleton, CO USA 80162-5005

As of the date of preparation of this document, the foregoing information is believed to be accurate and is provided in good
faith to comply with applicable federal and state law(s). However, no warranty or representation with respect to such
information is intended or given.

Date MSDS # Reason
08/01/00 1012-1.0000 New MSDS authoring system.
07/05/01 1012-1.0001 Sect. 15: corrected inventory status of continuous filament glass
fiber.
03/19/02 1012-1.1002 Minor edits.
09/13/04 1012-1.0003 Sect 1. addition of ThermoFlow庐 700 Series to trade names; Label
ID update. Sect. 2 addition of fiber diameter and sizing description.
07/03/06 1012-1.0004 Section 2 addition of the three TSCA 12b chemicals present only in
706 chopped strand sizing. Section 15 addition of article statement
for chemical inventories.
01/15/07 1012-1.0005 Section 15 removal of the three TSCA 12b chemicals (methyl
acetate, 2-methyl 3-isothiazolone, 5-chloro, 2-methyl-3-
isothiazolone) present only in 706 chopped strand sizing. These
products are articles under TSCA and are not required to be
reported under TSCA 12b per 40CFR 搂707.60(b).
03/07/08 1012-1.0006 Updated SDS to GHS format.



End of Sheet 1012




____________________________________________________________
Page 5 of 5 Issue Date: 03/07/2008 Revision: 1.0006

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
indfumco_com---Trapper_Glue_Boards_MSDS_6.22.05.asp N/A
indfumco_com---Trapper_Max_MSDS_3.29.05.asp N/A
indfumco_com---Trece_Lures_MSDS_5.13.05.asp N/A
indfumco_com---Trece_Trap_Glue_MSDS_8.17.05.asp N/A
indfumco_com---TRI-DIE_MSDS_10.17.06.asp N/A
indfumco_com---Turbocide_Gold_II_wPyrocide__MSDS_7.18.07.asp 008003-34-7 000051-03-6 000112-34-5
indfumco_com---Turbocide_II_wPyrocide_MSDS_7.18.07.asp 008003-34-7 000051-03-6 000124-38-9
indfumco_com---ULD_BP-100_MSDS.asp N/A
indfumco_com---ULD_BP-100_Plus_MSDS_6.22.05.asp N/A
indfumco_com---ULD_BP-300_Contact_Insecticide_MSDS_7.17.07.asp N/A
indfumco_com---Vangrip_MSDS_8.18.05.asp N/A
indfumco_com---Vap-20_CO2_MSDS_8.18.05.asp N/A
indfumco_com---Vap-5_MSDS_7.18.07.asp N/A
indfumco_com---Vapo-Cide_MSDS_7.2.07.asp N/A
indfumco_com---Vector_Bio-5_MSDS_8.18.05.asp N/A
indfumco_com---Vector_Nova_Supernova_with_Pher_MSDS_3.27.06.asp N/A
indfumco_com---Xlure_Combo-4_MSDS_10.2.06.asp N/A
indfumco_com---Xlure_RTU_Inspector_MSDS_3.27.06.asp N/A
indfumco_com---ZP_Rodent_Bait_MSDS.asp N/A
indfumco_com---ZP_Tracking_Powder_MSDS_9.20.04.asp N/A
jm_com---EN1001_CFr.asp 65997-17-3 1333-86-4
jm_com---EN1004_CFr.asp 65997-17-3
jm_com---EN1009_CFr.asp 65997-17-3 25038-59-9 25637-99-4 1333-86-4 1309-64-4
jm_com---EN1012.asp N/A
jm_com---EN1013_CFr.asp 65997-17-3 9011-05-6 471-34-1 50-00-0
jm_com---EN1014.asp 55918-56-4 9011-05-6 1333-86-4 50-00-0
jm_com---EN1021_CFr.asp 65997-17-3 1309-64-4
jm_com---EN1025.asp 65997-17-3 7429-90-5 1309-64-4
jm_com---EN1027.asp 8052-42-4 7429-90-5 65997-17-3 1309-64-4
jm_com---EN1035.asp 7732-18-5
jm_com---EN1041.asp 1333-86-4
jm_com---EN1042.asp 65997-17-3 100-97-0 1333-86-4 7664-41-7 50-00-0 108-95-2
jm_com---EN1056.asp 1309-64-4
jm_com---EN1064.asp N/A
jm_com---EN1075.asp N/A
jm_com---EN1105.asp 65997-17-3
jm_com---EN1121.asp N/A
jm_com---EN2055.asp 7732-18-5 1317-65-3 21645-51-2 1309-42-8 1309-64-4 68610-51-5 148-79-8 14808-60-7
jm_com---EN2402.asp 55918-56-4
jm_com---EN3012_CFr.asp 65997-17-3 78-78-4 287-92-3
jm_com---EN3106_Cfr.asp 108-88-3 67-64-1 142-82-5 110-54-3 64742-89-8 110-82-7 100-41-4 50-00-0
jm_com---EN3112.asp 65997-17-3 64742-93-4 25104-55-6 9003-07-0
jm_com---EN3129_Spanish.asp 1317-65-3 1333-86-4 63231-67-4 1305-78-8 64742-52-5 69102-90-5 7631-86-9 13463-67-7 14808-60-7
jm_com---EN3149_Cfr.asp 1330-20-7 100-41-4 108-88-3 71-43-2
jm_com---EN3152_Cfr.asp 1330-20-7 100-41-4 8052-41-3 13463-67-7 108-88-3
jm_com---EN3201_Spanish.asp N/A
jm_com---EN3204_Spanish.asp 141-78-6 75-07-0
jm_com---EN3206_Spanish.asp 109-99-9 108-94-1
jm_com---EN3208_Spanish.asp 13463-67-7 1317-65-3 1330-20-7 100-41-4 101-68-8 1333-86-4
jm_com---EN3225.asp 1317-65-3 1305-78-8

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC