MATERIAL SAFETY DATA SHEET
ROSCO NEW HAZEMAKER FLUID
I. PRODUCT IDENTIFICATION
******************************
Manufacturer鈥檚 Name: ROSCO LABORATORIES, INC.
Regular Telephone No: (203) 708-8900 Eastern Time
(323) 462-2233 Pacific Time
Emergency No: (800) 424-9300
Address: 52 Harbor View Avenue, Stamford, CT 06902, USA
Product Name: ROSCO NEW HAZEMAKER FLUID
Synonyms:
II. INGREDIENTS
*****************************
Material or Component: CAS
Polyethylene glycol 200 25322-68-3
De-ionized water
Material(s) or Component (s): There are no ingredients in this product that meet the
definitions of a hazardous material as determined in 29 CFR 1910.1200, Appendix B, (The
Hazard Communication Standard).
Occupational exposure limits (PELs or TLVs) have not been established for any of the
components of this products.
III . PHYSICAL DATA
*********************
Boiling Point: 244.8oC (estimated) Melting Point: -36 to 鈥?38 掳C
Specific Gravity (water = 1): >1 Vapor Pressure: <0.01 mm Hg
Vapor Density (air = 1): >1 Solubility: Soluble in water
1 of 5 pages
MATERIAL SAFETY DATA SHEET
ROSCO NEW HAZEMAKER FLUID
III. PHYSICAL DATA (Cont鈥檇)
***************************
% Volatiles by Vol.: 5% as water, < 0.01% VOCs Evaporation Rate (N = 1): < 1
(N= butyl acetate)
Molecular Weight: 190-210 g/M Molecular Composition:
(C2H4O)nH2O
Freezing Point: <-65o C pH: approx. 9-9.5
Density: 1.125 g/cm3
Appearance & Odor: Clear, colorless or slightly yellow-colored, bitter or slightly burning taste
IV. FIRE FIGHTING MEASURES
*******************************
Flash Point: Not Determined
Autoignition Temp.: Will not auto-ignite
Flammable Limits in Air (% by Vol.): Not Determined
Extinguishing Media: Non-flammable aqueous liquid, all purpose foam (large fires), CO2 or dry
chemical (small fires)
Special Fire Fighting Procedures: Use air-supplied breathing apparatus when fighting fires in
enclosed areas.
Unusual Fire and Explosion Hazard: Product will not burn
V. HEALTH HAZARD INFORMATION
************************************
Routes of Exposure: Inhalation, ingestion or dermal/eye contact
Effects of Over-exposure
Ingestion: This product is not an ingestion hazard.
2 of 5 pages
MATERIAL SAFETY DATA SHEET
ROSCO NEW HAZEMAKER FLUID
V. HEALTH HAZARD INFORMATION (Cont鈥檇)
******************************************
Inhalation: Non-irritating and non-lethal by inhalation. Persons with asthma or reactive
airway disorders (employees or spectators) should be warned that they may experience
asthma-like effects from exposure to this or any aerosolized material.
Skin contact: Prolonged skin contact with concentrated liquid can result in reversible
irritation.
Eye contact: Direct eye contact with liquid may cause transient mild reversible irritation.
Chronic: No chronic adverse health effects have been reported.
Emergency and First Aid Procedures
Eyes: If concentrated liquid contacts eyes, flush eyes with large amounts of water until
material is removed from eyes. If irritation persists seek medical attention.
Skin: If concentrated liquid contacts skin, flush with water and wash with soap to remove
residues. Remove contaminated clothing and wash before reuse. If skin irritation develops
and persists, seek appropriate medical attention.
Inhalation: This product is not an inhalation hazard, however if irritation occurs from
exposure to high vapor or aerosol concentrations, remove individual to fresh air.
Ingestion: Induce vomiting. Keep at rest and get prompt medical attention.
VI. REACTIVITY DATA
**********************
Conditions Contributing to Instability: None
Incompatibility: Strong oxidizers and acids
Hazardous Decomposition Products: None
Conditions Contributing to Hazardous Polymerization: None
3 of 5 pages
MATERIAL SAFETY DATA SHEET
ROSCO NEW HAZEMAKER FLUID
VII. SPILL OR LEAK PROCEDURES
**********************************
Steps to be taken if Material is Released or Spilled
Small Spills: Can be flushed into sewer if permitted by local, state and federal regulations.
Large Spills: Restrict area to personnel need to contain and cleanup spill. Soak up with
absorbent material and dispose of according to local, state or federal regulations
Neutralizing Chemicals: Not applicable
Waste Disposal Method: Contact commercial chemical waste company to dispose of waste
in accordance with federal, state, and local regulations.
VIII. SPECIAL PROTECTION INFORMATION
*******************************************
Ventilation Requirements: General ventilation should be satisfactory under normal use
conditions. If aerosol is used in a confined space, local exhaust ventilation may be used to
control mist.
Specific Personal Protective Equipment
Respiratory: No specific controls are needed. If aerosol is used in confined space, an
OSHA/NIOSH-approved respirator may be necessary.
Eye: No specific controls are required during normal use, however safety glasses can be used
to prevent eye contact with concentrated liquid when handling.
.
Skin: No specific controls are needed, however gloves that are not water soluble, e.g.
polyvinyl alcohol, can be used to prevent skin contact. Gloves are not generally needed
when handling the concentrated liquid under normal use conditions.
4 of 5 pages
MATERIAL SAFETY DATA SHEET
ROSCO NEW HAZEMAKER FLUID
IX. SPECIAL PRECAUTIONS
***************************
Precautionary Statements: None
Other Handling and Storage Requirements: None
X. REGULATORY INFORMATION
***************************
Clean Air Act: This material does not contain any hazardous air pollutants, Class I or II ozone
depletors.
Clean Water Act: This material does not contain any chemicals listed as a hazardous substance,
priority pollutant, or toxic pollutant under the Clean Water Act.
SARA: This material does not contain any materials that have a Reportable Quantity (RQ,
Section 302) or is reportable under Section 313 of SARA.
RCRA: Not listed as a material banned from land disposal.
International Regulations: This material does not contain any material that is on the Canadian
DSL/NDSL list. None of the ingredients in this material is on the Canadian Ingredient Disclosure
List.
California Proposition 65: This material is not listed as having a significant risk level.
*******************************************************************************
Prepared by: Stan Miller, President
Address: ROSCO Laboratories, Inc.
52 Harbor View Avenue
Stamford, CT 06902 USA
Date: June 1, 2001