Part No.: 19-0205-02
MATERIAL SAFETY DATA SHEET
Vector庐 Plasma鈩? Standard Light Bulb
EMERGENCY PHONE NUMBERS:
MEDICAL: 800-225-3320 (Prosar) TRANSPORTATION: 800-424-9300 (Chemtrec)
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION SECTION 7. HANDLING AND STORAGE
Product Name: Vector庐 Plasma鈩? Standard Light Bulb For indoor and outdoor use if not exposed to the weather. Must be kept dry.
It is the responsibility of the waste generator to ensure proper classification of waste products,
EPA Reg. No.: Not Regulated
including this one.
Light Trap Product Code(s): 20-1080 (Vector庐 Plasma鈩?)
20-1083 (Vector庐 Plasma鈩? Screen)
SECTION 8. EXPOSURE CONTROL / PERSONAL PROTECTION
20-1080-1 (Vector庐 Plasma One鈩?)
These instructions only apply to broken lamps. As stated in Section 3, small numbers of broken lamps will
20-1084 (Vector庐 Plasma One鈩? Screen)
present no adverse health effects.
EPA Signal Word: Not Regulated
PERSONAL PROTECTIVE EQUIPMENT (PPE)
Distributed by: Whitmire Micro-Gen Research Laboratories, Inc.
3568 Tree Court Industrial Blvd. Respiratory Protection: Use NIOSH approved respirator with a mercury cartridge or canister with
St. Louis MO 63122-6682 any P prefilter.
Eye Protection: The use of safety glasses, goggles or face shields is recommended for handling
SECTION 2. COMPOSITION/INFORMATION ON INGREDIENTS broken glass.
There are no known health hazards from exposure to lamps that are intact. Protective Clothing: Wear appropriate protective clothing to prevent skin exposure.
Unless specified otherwise, the following materials are from the glass bulb part of the complete lamp. Hygiene: After handling broken lamps wash thoroughly before eating, handling tobacco products,
applying cosmetics or using the toilet facilities.
Unless specified otherwise the percentage weight refers to the complete lamp.
If the lamp is broken then the following materials may be released: VENTILATION
COMPOSITION INFORMATION Use both general and local exhaust ventilation to maintain exposure levels below the long or short term limits.
Long Term Short Term
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Exposure Limit Exposure Limit
INGREDIENTS (100%) % 8 Hour TWA 15 minute CAS NO. Not applicable for intact lamps.
Glass (Soda Lime) 40-60 % NA
SECTION 10. STABILITY AND REACTIVITY
Fluorescent Phosphor as dust <0.5% 10.0 mg m3 NA
lO3 <0.1% 10.0 mg m3 1344-28-1 REACTIVITY
Mercury (Hg) <0.1% 0.025 mg m3 7439-97-6 Stability: Stable.
Barium compounds as dust <0.1% 0.5 mg m3 7440-39-3 Conditions to Avoid: None for intact lamps.
Yttrium Oxide (as Y dust) 0-0.5% 1.0 mg m3 3.0 mg m3 7440-65-5 Incompatibility (Materials to Avoid): None for intact lamps
This product as supplied is not considered hazardous as defined in the US Code of Federal Regulations, Hazardous Polymerization: Will not occur.
29CFR 1910.1200. This product is considered an 'article' as supplied for its intended and foreseen use. HAZARDOUS DECOMPOSITION PRODUCTS
SECTION 3. HAZARDS IDENTIFICATION None for intact lamps products.
SECTION 11. TOXICOLOGICAL INFORMATION
The breakage of one or a small number of lamps will not result in significant concentrations of Mercury
vapor or fluorescent phosphor powder in air.
Not applicable for intact lamps.
HAZARDOUS DECOMPOSITION PRODUCTS
SECTION 12. ECOLOGICAL INFORMATION
None for intact lamps.
Not applicable for intact lamps.
SECTION 4. FIRST AID MEASURES
SECTION 13. DISPOSAL CONSIDERATION
There are no known health hazards from intact lamps.
It is always the end user's responsibility to ensure that lamps are disposed of in accordance with local, state and
SECTION 5. FIRE FIGHTING MEASURES
federal regulations. Some states and localities have different criteria than the federal government's Toxicity
FLAMMABALITY Characteristic Leaching Procedure (TCLP) standard, and have different statutes and regulations regarding lamp
disposal. Consult your local and state authorities for correct lamp disposal requirements. To check state
The lamp is non-combustible
regulations or to locate a recycler visit the following web site: http://www.almr.org/support_files/stringency2.html
FIRE EXTINGUISHING MATERIALS
No special materials are required. Use the ones most appropriate for the surrounding fire. SECTION 14. TRANSPORT INFORMATION
SPECIAL FIRE-FIGHTING PROCEDURE
This product is suitable for any transportation method.
Use self-contained breathing apparatus to prevent inhalation of dust or fumes that may come from
lamps broken by the heat or fire-fighting activities. SECTION 15. REGULATORY INFORMATION
SECTION 6. ACCIDENTAL RELEASE MEASURES Not applicable for intact lamps.
IN CASE OF SPILL OR OTHER RELEASE SECTION 16. OTHER INFORMATION
The following applies to broken lamps only.
No other information available.
Do not breathe vapors or dust. Avoid contact with skin, eyes and clothing. Do not flush into surface
water, ground water or sanitary sewer. Collect together all components of lamp and place in clean dry
container and seal. Remove for appropriate disposal.
Emergency Telephone Number of Chemtrec: 800-424-9300 (for transportation spills)
The information and recommendations contained herein are based upon data believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made
with respect to the information contained herein. For automatic MSDS updates, register at www.wmmg.com.
Questions concerning the safe handling of the product should be referred to the Whitmire Micro-Gen customer service department at 800-777-8570.
NA 鈥? Not Applicable Effective Date: 7/19/05
WHITMIRE MICRO-GEN
NE 鈥? Not Established Review Date: NA
PEL 鈥? Permissible Exposure Limit Supersedes: NA
RESEARCH LABORATORIES, INC.
TLV 鈥? Threshold Limit Value Code: NA
STEL 鈥? Short Term Exposure Limit (15 min.) Text ID: 070314-1
TWA 鈥? Time Weighted Average (8 hrs.) WMG Part No: 19-0205-02
Page 1 of 1
|