MATERIAL SAFETY DATA SHEET
EMERGENCY NUMBER : 989-496-3780
SECTION I
Manufacturer鈥檚 Name: CPI Engineering Services, Inc.
Address: 2300 James Savage Road 鈥? P.O. Box 1924 - Midland, MI 48641-1924
Trade Name & Synonyms: CPI Compressor Cleaner (Sullair Part #250029-018 & 250029-019)
Chemical Family: Diester
SECTION II
HAZARDOUS INGREDIENTS
Hazardous Mixtures of Other Liquids, Solids, of Gases: No hazardous materials present. Product does not
contain any known carcinogens. No special label or hazard warnings are required under OSHA 29 CFR 1910.
SECTION III
PHYSICAL DATA
Boiling Point: 770掳F Specific Gravity (H2O=1): 0.91
Vapor Pressure (mm Hg.): Negligible Percent Volatile by Volume (%): Negligible
Vapor Density (Air=1): N/A Evaporation Rate: Negligible @ ambient temp.
Solubility in Water: Negligible
Appearance and Odor: Clear, light yellow, mild odor
SECTION IV
FIRE AND EXPLOSION HAZARD DATA
Flash Point (method used): 465掳F
Extinguishing Media: CO2, foam or dry chemical
Special Fire Fighting Procedures: Do not use water
Unusual Fire and Explosion Hazards: Avoid inhalation of smoke or vapors
SECTION V
HEALTH HAZARD DATA
Threshold Limit Value: TLV not established
Effects of Overexposure: May be a slight skin or eye irritant, although believed essentially non-toxic. May cause
diarrhea if ingested.
Emergency and First Aid Procedures:
Skin Contact - Wash with soap and water
Eye Contact - Flush well with water
Ingestion - Call a physician
Page 1
Product: CPI Compressor Cleaner
SECTION VI
REACTIVITY DATA
Stability: Stable
Hazardous Polymerization: Will not occur
SECTION VII
SPILL OR LEAK PROCEDURES
Steps to be taken in case material is released or spilled: Handle as a lubricating oil
Waste Disposal Method: Normal petroleum methodology
SECTION VIII
SPECIAL PROTECTION INFORMATION
Respiratory Protection (Specify type): None required under normal conditions.
Ventilation: Local exhaust in adequate
Protective Gloves: Use for prolonged exposure
Eye Protection: Use where splashing may occur
SECTION IX
SPECIAL PRECAUTIONS
Precautions to be taken in handling and storing: Normal precautions common to good manufacturing practice
should be followed in handling and storage.
SECTION X
WASTE DISPOSAL METHODS
Incinerate this product and all associated wastes in a licensed facility in accordance with Federal, State, and Local
Regulations.
The information in this Material Safety Data Sheet should be provided to all who use, handle, store, transport, or are
otherwise exposed to this product. CPI believes the information in this document to be reliable and up to date of
publication, but makes no guarantee that it is.
Page 2
|