Hyperdrill CP 905
Page 1 of 3
MATERIAL SAFETY DATA SHEET
SECTION I: IDENTIFICATION OF PRODUCT
PRODUCT NAME: Hyperdrill CP 905
PRODUCT USE: CAS NO.
Cationic Flocculant
CHEMICAL FAMILY: Cationic acrylamide copolymer powder
WORK PLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS)
WHMIS CLASSIFICATION: D2B
WORK PLACE HAZARD: Skin and Eye Irritant
TRANSPORTATION OF DANGEROUS GOODS (TDG)
SHIPPING NAME: Not Regulated Under TDG
TDG CLASSIFICATION: N/A
UN NUMBER (PIN): N/A
PACKING GROUP: N/A
SECTION II: HAZARDOUS INGREDIENTS
INGREDIENT PERCENT CAS NUMBER LD Oral-Rat LLC Rat-Inhal ACGIH-TLV
(50) (50)
No Information
SECTION III: TOXICOLOGICAL PROPERTIES
ROUTE OF ENTRY: [XX] SKIN [XX] EYE CONTACT [XX] INHALATION [ ] INGESTION
EYE CONTACT: Testing conducted according to the Draize technique showed the material
produces no corneal or iridial effects and only slight transitory conjectival effects
similar to those which all granular materials have on conjunctivae.
SKIN CONTACT: Non-irritating
INHALATION: This product is not expected to be toxic by inhalation.
SECTION IV: FIRST AID MEASURES
SKIN CONTACT: Wash with water and soap as a precaution. In case of skin irritation, consult a
physician.
EYE CONTACT: Rinse thoroughly with plenty of water. In case of persistent eye irritation, consult a
physician.
Hyperdrill CP 905
Page 2 of 3
MATERIAL SAFETY DATA SHEET
INGESTION: No hazards that require special first aid measures.
INHALATION: Move to fresh air if subject is overcome by excessive dust. Consult a physician in
case of irritation or other symptoms.
SECTION V: PHYSICAL DATA
APPEARANCE AND ODOUR: White, Granular solid; odourless
BOILING POINT (掳C): Not applicable
MELTING POINT (掳C): Not applicable
SOLUBILITY IN WATER: See Technical Bulletin
pH: 2.5-4.5 @ 5 g/l
PERCENT VOLATILE BY VOLUME: Not applicable
EVAPORATION RATE: Not applicable
VAPOUR PRESSURE (mm Hg): Not applicable
VAPOUR DENSITY (lb/ft3): Not applicable
SECTION VI: FIRE AND EXPLOSION HAZARD DATA
FLASH POINT: Not Considered Flammable
FLAMMABLE LIMITS: Not Determined
EXTINGUISHING MEDIA: Water, water spray, foam, dry powder, carbon dioxide
SPECIAL FIRE FIGHTING PROCEDURES: Aqueous solutions or powders that become wet render
surfaces extremely slippery.
UNUSUAL FIRE AND EXPLOSION HAZARDS: Negligible fire hazard when exposed to heat or flame.
SECTION VII: REACTIVITY DATA
STABILITY: Stable [XX] Unstable [ ]
INCOMPATIBILITY (CONDITIONS TO AVOID): Oxidizing agents may cause exothermic reactions.
HAZARDOUS DECOMPOSITION PRODUCTS: Thermal decomposition may produce: hydrogen
chloride gas, nitrogen oxides (Nox, and carbon
dioxides)
HAZARDOUS POLYMERIZATION: Will not occur [XX] May occur [ ]
Hyperdrill CP 905
Page 3 of 3
MATERIAL SAFETY DATA SHEET
VIII: PREVENTIVE MEASURES
SPECIAL PROTECTION INFORMATION
RESPIRATORY PROTECTION: Dust safety masks are recommended where
concentration of total dust is more that 15 mg/m3.
VENTILATION: Simply, good ventilation.
PROTECTIVE GLOVES: Suggest plastic or latex.
EYE PROTECTION: Safety glasses with side shields. Do not wear contact
lenses.
OTHER PROTECTIVE EQUIPMENT: Chemical resistant apron or protective suite is splashing
or repeated contact with solution is likely. Make eye
bath and emergency shower available.
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING
Store in cool, dry place. Keep containers tightly closed at all times. Avoid ingestion. Practice
reasonable caution and personal cleanliness. Avoid skin and eye contact. Wash thoroughly after
handling.
STEPS TO BE TAKEN IN CASE THE MATERIAL IS SPILLED OR RELEASED
Always use suggested or required safety equipment. Do not flush with water. Clean up promptly by
scoop or vacuum. Keep in suitable and closed containers for disposal. After cleaning, flush away traces
with water.
WASTE DISPOSAL METHOD
Burn is adequate incinerator or bury in landfill in accordance with all applicable regulations.
SECTION IX: PREPARATION
THE INFORMATION CONTAINED HEREIN IS GIVEN IN GOOD FAITH, BUT NO WARRANTY,
EXPRESSED OR IMPLIED, IS MADE.
DATE PRINTED: BY: MILLENNIUM TECHNOLOGIES LTD.
April 6, 2006
DATE MODIFIED: June 20, 2005 APPROVED BY:
SUPERSEDES: October 1, 2003
24 HOUR PHONE: 403-252-5904
|