AQ 191A
Page 1 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
SECTION I: PRODUCT INFORMATION
Sika速 AnchorFix速-1
PRODUCT: PART A REVISION DATE: February 13, 2007
USAGE:
MANUFACTURER: Exchem Mining & Construction SUPPLIER: SIKA CANADA INC.
P.O. Box 7, Venture Crescent 601, avenue Delmar
Alfreton, Derbyshire Pointe Claire, QC
DE55 7RE, England H9R 4A9, Canada
EMERGENCY TELEPHONE NUMBER: CANUTEC (collect) (613) 996-6666
TDG CLASSIFICATION: Not Regulated UN NUMBER: Not Regulated
TDG Class: Not Regulated Packaging Group: Not Regulated
WHMIS Classification: B3, D2A, D2B
SECTION II: HAZARDOUS INGREDIENTS
Hazardous % T.L.V. # CAS LD50 (mg/kg) LC50
(species, route) (species, route)
Ingredients (mg/m3)
SILICA SAND 30-60 0.10 14808-60-7 N.A. N.A.
DIETHYLENEGLYCOL
5-10 N.A. 2358-84-1 N.A. N.A.
DIMETHACRYLATE
DIVINYL BENZENE
5-10 N.A. 1321-74-0 N.A. N.A.
(MIXED ISOMERS)
* Exposure to silica, quartz is applicable only if cured with part B and sanded.
SECTION III: PHYSICAL CHARACTERISTICS
Physical State: Paste, Solid Boiling Point: Not Established
Appearance and Odor: White Paste /Characteristic Freezing Point: Not Established
odor Density: 1.6 g/ml
Odor Threshold: Not Established Solubility in water: Insoluble
Evaporation Rate: Not Established pH: Not Established
Vapor Density: Not Established % volatile: Not Established
Vapor Pressure: Not Established Coefficient water/oil: Not Established
AQ 191A
Page 2 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART A
SECTION IV: FIRE AND EXPLOSION HAZARDS
Flammability: Not known TDG Flammability Class: Not Regulated
If Yes, under what conditions: Flammable upper limits (% vol.): Not Established
Flammable lower limits (% vol.): Not Established
Flash Point (method used): 69属C
Extinguishing methods: CO2, alcohol or polymer Auto-ignition temperature: Not Established
foam, alcohol resistant
foam. Dangerous Combustion Products: Carbon oxides,
Fire and Explosion Hazards: None known Explosion Data :
Protect from mechanical impact: No
Special Methods: Fire fighters must wear
usual protective clothing
Protect from static discharge: No
and NIOSH-approved self
contained breathing
respiratory equipment
with a full face piece
operated in the pressure
demand or other positive
pressure mode.
SECTION V: REACTIVITY DATA
Chemical stability: Stable, Dangerous decomposition products: Carbon oxides,
If not, under what conditions: Heat, sources of aldehydes and
ignition other organics
Incompatibility with other material: Yes Polymerization Risks: Will not occur.
If Yes, which ones: Strong oxidizing
Conditions to avoids: Heat, sources of
materials, acids
ignition
and bases
AQ 191A
Page 3 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART A
SECTION VI: TOXIC PROPERTIES
ROUTE OF ENTRY / CONTACT
Eyes: Cause irritation. Carcinogenicity Not accordingly to NTP or
OSHA; According to the
IARC the quartz silica is a
Skin: May cause irritation. probable cause of cancer.
Inhalation: May cause respiratory tract irritation. Toxic effects on reproduction: No established
Ingestion: May be harmful if swallowed. Teratogenicity: No established
Mutagenicity: No established
Product with synergistic effect.: Not established
Chronic or acute exposure will increase the problems such as eye disease, skin disorders and allergies, chronic
respiratory disease.
AQ 191A
Page 4 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART A
SECTION VII: PREVENTIVE MEASURES
PERSONAL PROTECTIVE EQUIPMENT OTHERS
Gloves: Chemical resistant gloves. Ventilation: Use of a system of local and/or
general exhaust to keep
Respiratory equipment: NIOSH approved mask for VOC employee below applicable
when the permissible exposure exposure limits.
limit might be exceeded
Procedure in
Eyes: Safety glasses or goggles. case of leaks: Avoid release to the environment.
Wear proper protective
Shoes: Safety shoes equipment. Contain spill and
collect with absorbent material
Clothing: Lab coat or other work clothing. and transfer into suitable
Launder before reuse. containers. Do not flush to sewer
or allow entering waterways.
Other: Eye wash station, shower Ventilated enclosed area.
available closely. Wash hands
before smoking or eating. Handling and
Equipment methods: Wash thoroughly with soap and
water after handling.
Warehouse
Requirements: Keep all containers tightly closed.
Keep in a cool, dry and well
ventilated area.
Special Shipping
Instructions: See TDG class.
Waste Disposal: Dispose in accordance with
applicable municipal, provincial or
federal regulations.
AQ 191A
Page 5 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART A
SECTION VIII: FIRST AID
Skin : Remove contaminated clothing and shoes.
Wash clothing before re-wearing.
Wash immediately with plenty of soap and water for at least 15 minutes.
If symptoms develop (redness, rash, blistering), consult a physician.
Eyes : Rinse eyes immediately, holding eyelids apart, with plenty of water for at least 15
minutes.
Consult a physician if irritation develops and persists.
Inhalation : In the case of overexposure, evacuate to fresh air.
If breathing has stopped, institute artificial respiration.
Consult a physician.
Ingestion : Dilute with one or two cups of water or milk.
Do not induce vomiting, unless to do so by medical personnel.
Do not give anything by mouth to an unconscious person.
See a physician immediately.
SECTION IX: PREPARATION INFORMATION
Prepared By : Steve Gosselin
Telephone # : (514) 697-2610
Fax # : (514) 694-2792
Notice To Reader
The information contained in this Material Safety Data Sheet applies only to the actual Sika Canada product identified and described herein. This
information is not intended to address, nor does it address the use or application of the identified Sika product in combination with any other material,
product or process. All of the information set forth herein is based on technical data regarding the identified product that Sika believes to be reliable
as of the date hereof. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's
current Technical Data Sheet, product label and Material Safety Data Sheet for each Sika product, which are available at web site and/or telephone
number listed in Section 1 of this MSDS.
SIKA MAKES NO WARRANTIES EXPRESS OR IMPLIED AND ASSUMES NO LIABILITY ARISING FROM THIS INFORMATION OR ITS USE.
SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES AND SHALL NOT BE
RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL
PROPERTY RIGHTS HELD BY OTHERS.
All sales of Sika products are subject to its current terms and conditions of sale available at www.sikacanada.com or 514-697-2610.
AQ 191A
Page 1 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
SECTION I: PRODUCT INFORMATION
Sika速 AnchorFix速-1
PRODUCT: PART B REVISION DATE: February 13, 2007
USAGE:
MANUFACTURER: Exchem Mining & Construction SUPPLIER: SIKA CANADA INC.
P.O. Box 7, Venture Crescent 601, avenue Delmar
Alfreton, Derbyshire Pointe Claire, QC
DE55 7RE England H9R 4A9, Canada
EMERGENCY TELEPHONE NUMBER: CANUTEC (collect) (613) 996-6666
TDG CLASSIFICATION: Not Regulated UN NUMBER: Not Regulated
TDG Class: Not Regulated Packaging Group: Not Regulated
WHMIS Classification: C, D2B
SECTION II: HAZARDOUS INGREDIENTS
Hazardous % T.L.V. # CAS LD50 (mg/kg) LC50
(species, route) (species, route)
Ingredients (mg/m3)
22.4 mg/L 4H
10-30 94-36-0
BENZOYL PEROXIDE 5.0 > 950 to > 5,000
(Inh., rat)
SECTION III: PHYSICAL CHARACTERISTICS
Physical State: Paste, solid Boiling Point: Not Established
Appearance and Odor: Black paste, no odor Freezing Point: Not Established
Density: Not Established
Odor Threshold: Not Established Solubility in water: Insoluble
Evaporation Rate: Not Established pH: Not Established
Vapor Density: Not Established % volatile: Not Established
Vapor Pressure: Not Established Coefficient water/oil: Not Established
Gravity: 1.5
AQ 191A
Page 2 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART B
SECTION IV: FIRE AND EXPLOSION HAZARDS
Flammability: Not known TDG Flammability Class: Not Regulated
If Yes, under what conditions: Flammable upper limits (% vol.): Not Established
Flammable lower limits (% vol.): Not Established
Flash Point (method used): Not Applicable
Extinguishing methods: CO2, alcohol or polymer Auto-ignition temperature: Not Established
foam, alcohol resistant
foam. Dangerous Combustion Products: Carbon oxides,
nitrogen oxides.
Fire and Explosion Hazards: During a fire, irritating
and/or toxic gases and Explosion Data :
aerosols from the
Protect from mechanical impact: No
decomposition /
combustion products may
Protect from static discharge: No
be present.
Special Methods: Fire fighters must wear
usual protective clothing
and NIOSH-approved self
contained breathing
respiratory equipment
with a full face piece
operated in the pressure
demand or other positive
pressure mode.
SECTION V: REACTIVITY DATA
Chemical stability: Stable, Dangerous decomposition products: Carbon oxides,
If not, under what conditions: Heat, sources of nitrogen oxides.
ignition
Polymerization Risks: Will not occur.
Incompatibility with other material: Yes
Conditions to avoids: Heat, sources of
If Yes, which ones: Strong oxidizing
ignition
materials, acids
and bases
AQ 191A
Page 3 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART B
SECTION VI: TOXIC PROPERTIES
ROUTE OF ENTRY / CONTACT
Eyes: Cause irritation. Carcinogenicity Benzoyl peroxide listed in
the IARC monographs.
Skin: May cause skin irritation. Prolonged
and/or repeated skin contact may cause Toxic effects on reproduction: Not established
an allergic reaction/sensitization.
Teratogenicity: Not established
Inhalation: May cause nose, throat and lung irritation.
Mutagenicity: Not established
Ingestion: May be harmful if swallowed.
Product with synergistic effect.: Not established
Conditions aggravated by exposure: eye disease, skin
disorders and allergies, chronic respiratory disease.
Chronic or acute exposure will increase the problems mentioned in this section.
AQ 191A
Page 4 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART B
SECTION VII: PREVENTIVE MEASURES
PERSONAL PROTECTIVE EQUIPMENT OTHERS
Gloves: Chemical resistant gloves. Ventilation: Use adequate local general and
local exhaust ventilation to keep
Respiratory equipment: In areas where the T.L.V. is employee below applicable
exceeded, use a fitted NIOSH- exposure limits.
approved respirator.
Procedure in
Eyes: Safety glasses or goggles. case of leaks: Wear proper protective
equipment. Avoid contact.
Shoes: Safety shoes Contain spill and collect with
absorbent material and transfer
Clothing: Lab coat or other work clothing. into suitable containers. Do not
Launder before reuse. flush to sewer or allow entering
waterways. Ventilated enclosed
Other: Eye wash station, shower area.
available closely. Wash hands
thoroughly before smoking or Handling and
eating. Equipment methods: Avoid skin, eye and clothing
contact. Wash thoroughly with
soap and water after handling.
Warehouse
Requirements: Keep all containers tightly closed.
Keep in a cool, dry and well
ventilated area.
Special Shipping
Instructions: See TDG class.
Waste Disposal: Dispose in accordance with
applicable municipal, provincial or
federal regulations. Follow in-
house procedure.
AQ 191A
Page 5 of 5
MATERIAL SAFETY DATA SHEET
Sika Canada Inc. Date:99/09/30
App. SG
Sika速 AnchorFix速-1
PRODUCT: PART B
SECTION VIII: FIRST AID
Skin : Remove contaminated clothing and shoes. Wash clothing before re-wearing.
Wash immediately with plenty of soap and water for at least 15 minutes.
Consult a physician if irritation (redness, rash, blistering) develops and persists.
Eyes : Rinse eyes immediately, holding eyelids apart, with plenty of water for at least 15
minutes.
Consult a physician immediately.
Inhalation : In the case of overexposure, evacuate to fresh air.
If breathing has stopped, institute artificial respiration.
Consult a physician.
Ingestion : Drink plenty of water.
Do not induce vomiting unless directed to do so by medical personnel.
Do not give anything by mouth to an unconscious person.
See a physician immediately.
SECTION IX: PREPARATION INFORMATION
Prepared By : Steve Gosselin
Telephone # : (514) 697-2610
Fax # : (514) 694-2792
Notice To Reader
The information contained in this Material Safety Data Sheet applies only to the actual Sika Canada product identified and described herein. This
information is not intended to address, nor does it address the use or application of the identified Sika product in combination with any other material,
product or process. All of the information set forth herein is based on technical data regarding the identified product that Sika believes to be reliable
as of the date hereof. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's
current Technical Data Sheet, product label and Material Safety Data Sheet for each Sika product, which are available at web site and/or telephone
number listed in Section 1 of this MSDS.
SIKA MAKES NO WARRANTIES EXPRESS OR IMPLIED AND ASSUMES NO LIABILITY ARISING FROM THIS INFORMATION OR ITS USE.
SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES AND SHALL NOT BE
RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL
PROPERTY RIGHTS HELD BY OTHERS.
All sales of Sika products are subject to its current terms and conditions of sale available at www.sikacanada.com or 514-697-2610.
|