Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

2216-51-5

File Name: xenexlabs_com---msds.me100x.asp
                                   MATERIAL SAFETY DATA SHEET
SECTION 1 - PRODUCT IDENTIFICATION AND USE
PRODUCT IDENTIFICATION NUMBER (PIN):
PRODUCT IDENTIFIER
Menthol Crystals USP ME100X
PRODUCT USE
in cough drops and perfumery
MANUFACTURERS NAME: SUPPLIERS NAME:
Xenex Labs XENEX LABORATORIES INC.
STREET ADDRESS: STREET ADDRESS:
2402 CANOE AVENUE
CITY: PROVINCE: CITY: PROVINCE:
COQUITLAM B.C.
POSTAL CODE: EMERGENCY TELEPHONE NO: POSTAL CODE: EMERGENCY TELEPHONE NO:
SPE100 V3K 6C2 (CHEMTREC) 1-800-424-9300
SECTION 2 - HAZARDOUS INGREDIENTS
HAZARDOUS INGREDIENTS
% CAS NUMBER LD50 / LC50 OF INGREDIENT
/ CHEMICAL FORMULA
(SPECIFY SPECIES) (SPECIFY ROUTE AND DOSE)

Menthol Crystals USP 100 2216-51-5 RAT ORAL 3300mg/kg
MOUSE ORAL 3400mg/kg
CAT ORAL 800mg/kg
RABBIT DERMAL 5001mg/kg


SECTION 3 - PHYSICAL DATA
PHYSICAL STATE AND APPEARANCE ODOR TASTE ODOR THRESHOLD (ppm)
Solid (Crystals) Translucent Characteristic Not Available Not Available
MELTING POINT (C) BOILING POINT (C) VOLATILITY VAPOR PRESSURE VAPOR DENSITY
42掳C (107掳F) 212掳C (413.6掳F) Not Available Not Available 5.38
pH SPECIFIC GRAVITY COEFF. WATER/OIL DIST. DISPERSION PROPERTIES / SOLUBILITY
Not Available 0.89 (Water=1) Not Available Insoluble in cold water
SECTION 4 - FIRE AND EXPLOSION DATA
NO YES
FLAMMABILITY IF YES, UNDER WHAT CONDITIONS?
May be combustible at high temperatures

MEANS OF EXTINCTION
SMALL: Use DRY chemical powder.
LARGE: Use water spray, fog or foam. Do NOT use water jet.
FLASHPOINT (C) AND METHOD FLAMMABLE LIMITS (% BY VOLUME) CRITICAL TEMPERATURE
(CC 93掳C / 199.4掳F) UPPER: Not Available LOWER: Not Available
AUTOIGNITION TEMPERATURE (C) HAZARDOUS COMBUSTION PRODUCTS
Not Available (CO,CO2) Oxides of carbon. Acrid smoke and fume
SECTION 5 - REACTIVITY DATA
YES NO IF NO, UNDER WHICH CONDITIONS?
CHEMICAL STABILITY
The product is stable

NO YES
INCOMPATIBILITY WITH OTHER SUBSTANCES IF SO, WHICH ONES?
Not Available

REACTIVITY, AND UNDER WHAT CONDITIONS
Not Available

HAZARDOUS DECOMPOSITION PRODUCTS
The products of degradation are more toxic
MATERIAL SAFETY DATA SHEET
ME100X
PRODUCT IDENTIFIER
Menthol Crystals USP
SECTION 6 - TOXICOLOGICAL PROPERTIES
ROUTE OF ENTRY
INGESTION
INHALATION
SKIN CONTACT SKIN ABSORPTION EYE CONTACT
EFFECTS OF ACUTE EXPOSURE TO PRODUCT
Effects Hazardous in case of skin contact (irritant), of eye contact (irritant), of ingestion, of inhalation. Slightly hazardous in case of skin contact (permeator)

EFFECTS OF CHRONIC EXPOSURE TO PRODUCT
Repeated or prolonged exposure is not known to aggravate medical condition.
EXPOSURE LIMITS IRRITANCY OF PRODUCT SENSITIZATION OF PRODUCT CARCINOGENICITY
Not Available YES Not Available Not Available
REPRODUCTIVE TOXICITY MUTAGENICITY SYNERGISTIC PRODUCTS
TERATOGENICITY
Not Available Not Available Not Available Not Available
SECTION 7 - PREVENTATIVE MEASURE
PERSONAL PROTECTIVE EQUIPMENT
GLOVES (SPECIFY) RESPIRATOR (SPECIFY) EYE (SPECIFY)
Yes ( impervious ) Approved / Certified respirator Safety goggles, face shield
FOOTWEAR (SPECIFY) CLOTHING (SPECIFY) OTHER (SPECIFY)
No Coveralls / Lab coat Eyewash equipment nearby
ENGINEERING CONTROLS (SPECIFY eg. VENTILATION, ENCLOSED PROCESS)
Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user
operations generate dust, fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.
LEAK AND SPILL PROCEDURE
Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface.


WASTE DISPOSAL
According to local, provincial, and federal regulations.
HANDLING PROCEDURES AND EQUIPMENT
Keep away from heat. Keep away from sources of ignition. Empty containers pose a fire risk, evaporate the residue under a fume hood. Ground all equipment
containing material. Do not ingest. Do not breathe dust. Wear suitable protective clothing In case of insufficient ventilation, wear suitable respiratory equipm
If ingested, seek medical advice immediately and show the container or the label. Avoid contact with skin and eyes


STORAGE REQUIREMENTS
Keep container tightly closed. Keep container in a cool, dry, well-ventilated area. Container may be hazardous when empty since they retain product residues
(Dust, Solids) observe all warnings and precautions listed for the product
SPECIAL SHIPPING INFORMATION
No special requirements
SECTION 8 - FIRST AID MEASURES
SPECIFIC MEASURES
SKIN After contact with skin, wash immediately with plenty of water. Gently and thoroughly wash the contaminated skin with running
water and non-abrasive soap. Be particularly careful to clean folds, crevices, creases and groin. Cover the irritated skin with an
emollient. If irritation persists, seek medical attention. Wash contaminated clothing before reusing.


Check for and remove any contact lenses. Do not use eye ointment. Get medical attention
EYES
Allow the victim to rest in a well ventilated area. Seek immediate medical attention.
INHALATION
INGESTION Do NOT induce vomiting. Examine the lips and mouth to ascertain whether the tissues are damaged, a possible indication that the
toxic material was ingested; the absence of such signs, however, is not conclusive. Loosen tight clothing such as a collar, tie, belt
or waistband. If the victim is not breathing, perform mouth-to-mouth resuscitation. Seek immediate medical attention.


IF IRRITATION PERSISTS AND IN ALL OTHER CASES, GET IMMEDIATE MEDICAL ATTENTION.
SECTION 9 - PREPARATION DATE OF M.S.D.S.
All chemicals may pose unknown hazards and should be used with caution. This Material Safety Data Sheet (MSDS) applies only to the material as packa
If this product is combined with other materials, deteriorates, or becomes contaminated, it may pose hazards not mentioned in this MSDS. It shall be the us
responsibility to develop proper methods of handling and personal protection based on the actual conditions of use. While this MSDS is based on technical
data judged to be reliable, Xenex Laboratories Inc. assumes no responsibility for the completeness or accuracy of the information contained herein.


PREPARED BY (GROUP, DEPARTMENT, ETC.) PHONE NUMBER DATE:
CONTROL DEPARTMENT (604) 552 3031 November 08 2006

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
xenexlabs_com---msds.as115x.asp 137-66-6
xenexlabs_com---msds.be120x.asp 1302-78-9
xenexlabs_com---msds.be150x.asp 65-85-0
xenexlabs_com---msds.be160x.asp 64-17-5 9000-05-9 8001-97-6
xenexlabs_com---msds.be184x.asp 100-51-6
xenexlabs_com---msds.ca110x.asp 66-22-7 58-08-2 77-92-9
xenexlabs_com---msds.ca135x.asp 21059-46-1
xenexlabs_com---msds.ch100x.asp 7440-44-0
xenexlabs_com---msds.de040x.asp 134-62-3
xenexlabs_com---msds.de105x.asp 99-26-3
xenexlabs_com---msds.de130x.asp 50-99-7
xenexlabs_com---msds.ed050x.asp 23411-34-9
xenexlabs_com---msds.ep110x.asp 10034-99-8
xenexlabs_com---msds.et100x.asp 60-29-7
xenexlabs_com---msds.et104x.asp 111-90-0
xenexlabs_com---msds.eu100x.asp 470-82-6
xenexlabs_com---msds.fe1140x.asp 7782-61-8
xenexlabs_com---msds.fl190x.asp 51-21-8
xenexlabs_com---msds.fo100x.asp N/A
xenexlabs_com---msds.fo110x.asp N/A
xenexlabs_com---msds.fo115x.asp N/A
xenexlabs_com---msds.fr100x.asp 64-17-5
xenexlabs_com---msds.fu099x.asp 569-61-9
xenexlabs_com---msds.fu110x.asp 8031-18-3
xenexlabs_com---msds.ge110x.asp 548-62-9
xenexlabs_com---msds.ge118x.asp 7732-18-5 548-62-9
xenexlabs_com---msds.gl080x.asp 29031-19-4
xenexlabs_com---msds.gl100x.asp 56-86-0
xenexlabs_com---msds.gl110x.asp 7732-18-5 111-30-8
xenexlabs_com---msds.gl140x.asp 31566-31-1 9004-99-3
xenexlabs_com---msds.gl155x.asp 56-40-6
xenexlabs_com---msds.gl170x.asp 7732-18-5 79-14-1
xenexlabs_com---msds.hy050x.asp 10034-93-2
xenexlabs_com---msds.hy111x.asp 7732-18-5 7722-84-1
xenexlabs_com---msds.ic105x.asp 133-32-4
xenexlabs_com---msds.id100x.asp 7553-56-2
xenexlabs_com---msds.id110x.asp 7732-18-5 7553-56-2 7681-82-5 64-17-5
xenexlabs_com---msds.is170x.asp 67-63-0
xenexlabs_com---msds.ka050x.asp 1332-58-7
xenexlabs_com---msds.ke100x.asp 65277-42-1
xenexlabs_com---msds.la120x.asp 8006-54-0
xenexlabs_com---msds.la121x.asp 8006-54-0 7732-18-5
xenexlabs_com---msds.lh050x.asp 71-00-1
xenexlabs_com---msds.me100x.asp 2216-51-5
xenexlabs_com---msds.me249x.asp 5026-62-0
xenexlabs_com---msds.me260x.asp 119-36-8
xenexlabs_com---msds.my110x.asp 64-17-5
xenexlabs_com---msds.na100x.asp 91-20-3
xenexlabs_com---msds.nn100x.asp 59-67-6
xenexlabs_com---msds.oa100x.asp 8007-69-0

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC