COASTWIDE LABORATORIES Hazard Rating HMIS NFPA
CORPORATE EXPRESS Health 2 2
10000 SW Commerce Circle Flammability 0 0
Wilsonville, OR 97070 Reactivity 0 0
Office PHONE: 800-775-3289 or FAX 888-549-3344 Special None None
MEDICAL 800-808-4691 DOT CHEMTREC: 800-424-9300
24-HR EMERGENCIES:
MATERIAL SAFETY DATA SHEET
Complies with ANSI Z400.1 Format
SECTION 1: PRODUCT IDENTIFICATION
TM
HEPASTAT 256 CL4250.1006; CL4250QM; CL1064.1006
Product: MSDS CODES:
This MSDS is also for H n yMi鈩? and Quick Mix庐 10 Hepastat 256 Disinfectant-Cleaner
ad x
GENERIC DESCRIPTION DATE ISSUED SUPERSEDES PREPARED BY
Disinfectant Cleaner 10-1-06 3-1-06 Regulatory Department
SECTION 2: COMPOSITION AND INFORMATION ON INGREDIENTS
Components* % by Wt. CAS # Exposure Limit
Quaternary Ammonium Salts 10-20 NA None
Nonionic Surfactant 04-08 68439-46-3 TLV not established
Ethanol 01-03 64-17-5 1000 ppm OSHA PEL/STEL
Sodium Metasilicate 01-02 497-19-8 None
Sodium EDTA 04-08 64-02-8 None
Balance is water and similar non-hazardous ingredients.
*There are no components in this product that are currently reportable in either SARA Title III: Sections
313, 40 CFR part 372 or the California Proposition 65 requirements.
NA = Not applicable NSR = No Special Requirements ND = Not Determined PEL = OSHA TLV-TWA = ACGIH
SECTION 3: HAZARD IDENTIFICATION
Skin, eyes, inhalation and ingestion. Signs & Symptoms of Exposure: Direct contact of
Primary Entry Routes:
concentrated product with eyes or skin may cause burns. Prolonged or repeated contact of concentrated product
with skin may cause burns. May be harmful if swallowed! Prolonged inhalation of concentrated product vapor or
mist may cause respiratory discomfort.
Effects of Overexposure: Causes eye and skin burns. Harmful if swallowed.
SECTION 4: FIRST AID MEASURES
Wash skin with plenty of water. If irritation persists, seek medical aid. If eye contact
Emergency First Aid Procedures:
occurs, flush eyes with water for 15-20 minutes, then get prompt medical aid. If product is swallowed, drink large
amounts of water or milk and seek medical aid.24-HR MEDICAL PHONE: 800-808-4691
SECTION 5: FIRE FIGHTING MEASURES
Flash Point: NONE Flammable Limits: ND Extinguishing Media: Foam. CO2. Dry Chemical. Water or Fog.
Special Fire Fighting Procedures: Normal fire fighting procedures may be used.
Unusual Fire and Explosion Hazards: Container may melt and leak in heat of fire. Liquid run-off to sewers may
create fire and explosion hazard.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Before attempting clean-up, refer to Hazard Data above. Remove ignition sources. Contain spill.
Release or Spill:
Use mop, absorbent, or wet vacuum to collect material for proper disposal. Rinse area with water.
SECTION 7: HANDLING AND STORAGE
Store in a cool, dry place with adequate ventilation. Keep out of reach of children.
Coastwide Laboratories
Material Safety Data Sheet
Page 2 鈥揌EPASTAT 256TM MSDS CODES: CL4250.1006; CL4250QM; CL1064.1006
SECTION 8: EXPOSURE CONTROLS AND PERSONAL PROTECTION
Respiratory Protection: No special requirements under normal use conditions. Maintain adequate ventilation.
Protective Gloves: For undiluted product and where contact is possible, wear rubber or other impervious gloves.
Eye Protection: For undiluted product and where contact is possible, wear chemical workers splash-proof goggles
and/or face shield. Other Protective Measures: Use good personal hygiene practices. Launder contaminated
clothing/equipment.
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
Appearance/Odor: Red, clear liquid, mild fragrance Boiling Point: 212F Evap. Rate: NA pH: 11.5 and 8.5-9.5 (0.5%):
Vapor Density: ND Vapor Pressure: NA Specific Gravity: 1.04 Solubility in Water: Complete %Volatile: ND
SECTION 10: STABILITY AND REACTIVITY
Stability: Stable None known to Coastwide Laboratories Incompatibility: Acids, other
Conditions to Avoid:
detergents and chlorine.
Hazardous Decomposition Products: Thermal decomposition may yield hydrogen chloride and oxides of carbon.
Hazardous Polymerization: Will not occur. Conditions to Avoid: None known to Coastwide Laboratories.
SECTION 11: TOXICOLOGICAL INFORMATION
LD50 in rats is 5000 mg/kg of body weight.
Oral Toxicity:
SECTION 12: ECOLOGICAL INFORMATION
After this product is used as a disinfectant, the organic surfactants biodegrade in sewage systems and/or the
environment!
SECTION 13: DISPOSAL CONSIDERATIONS
PESTICIDAL WASTE - Observe all applicable Federal/State regulations and local
Waste Disposal Information:
ordinances regarding disposal of pesticide wastes. Waste from normal product use may be sewered to a
POTW. Pesticide wastes are acutely hazardous. Improper disposal of excess pesticides is a violation of Federal
Law. DISPOSAL AND/OR SPILL INFORMATION: Do not allow to soak into the ground or to enter a storm
drain.
SECTION 14: TRANSPORT INFORMATION
DOT EMERGENCY 24-HR: 800-424-9300 DOT Class: Limited quantity exemption for Handy Mix 陆 g ln
鈩? ao
l
and 1-gallon containers.
SECTION 15: REGULATORY INFORMATION
Ingredients in this product are not currently subject.
SARA Title III Section 313 and 40 CFR Part 372 Notification:
No ingredients in this product are currently listed as carcinogens by NTP, IARC or OSHA. All components of
this product are listed or are excluded from listing on the U.S. Toxic Substances Control Act (TSCA) Chemical
Substance Inventory.
SECTION 16: OTHER INFORMATION
Keep out of reach of children. Do not get in eyes, on skin or clothing. Harmful if swallowed. Avoid contamination
of food. Avoid inhalation of spray mist. Always follow label directions carefully when using this or any chemical
product. Keep MSDSs filed and organized in an area accessible to workers according to the Hazard
Communication Standards. If information about this product is required, please contact COASTWIDE
Laboratories at 800-775-3289.
All information appearing herein is given in good faith. No warranty is made, expressed or implied including
merchantability or fitness for a particular purpose. All conditions of use are beyond the control of Coastwide
Laboratories. Therefore, users are responsible for verifying the data under their own operating conditions to
determine whether the product is suitable for their particular purposes. The data contained herein is confidential
and intended solely for the user's internal use.
|