NuGenTec                           MATERIAL SAFETY DATA SHEET                     Page 1 of 6
CAGE CODE: 1D6V1 KIT Containing Three Components/Items Feb 24, 2007

Contractor Identification
NuGeneration Technologies, LLC www.nugentec.com
100 Professional Center Drive, Rohnert Park, CA 94928
(707) 820-4080 (For product information)
1-800-424-9300 or 1-202-483-7616 (CHEMTREC: For emergencies)


DEVELOPER -- 6850-00-826-0981
===================== Product Identification =====================

Product ID: DEVELOPER
MSDS Date: 03/18/2005
FSC:6850
Kit Part: A
MSDS Number: 826-0981
PN: NGT-826-0981

============= Composition/Information on Ingredients =============

Ingred Name:ISOPROPYL ALCOHOL (SARA III)
CAS:67-63-0
RTECS #:NT8050000
Other REC Limits: NONE RECOMMENDED
OSHA PEL:400 PPM/500 STEL
ACGIH TLV:400 PPM/500STEL;9293

===================== Hazards Identification =====================

LD50 LC50 Mixture:TLV=400PPM (ISOPROPANOL)
Routes of Entry: Inhalation: YES Skin:YES Ingestion:NO
Reports of Carcinogenicity: NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic: INHAL:MAY CAUSE MILD IRRITATION, CNS
DEPRESSION. SKIN: MILDLY IRRITATING.INGEST: PRODUCT HAS A LOW ORDER OF
ORAL TOXICITY.
Explanation of Carcinogenicity:THERE ARE NO INGREDIENTS ABOVE 0.1%
WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure:INHAL:IRRITATION OF THE
EYES,SKIN,NOSE, RESPIRATORY TRACT, HEADACHE, GIDDINESS, HEADACHE, NAUSEA.
Medical Cond Aggravated by Exposure: PREEXISTING CONDITIONS OF THE
SKIN,EYES AND RESPIRATORY SYSTEM MAY BE AFFECTED BY EXPOSURE TO
THIS MATERIEL.

======================= First Aid Measures =======================

First Aid:EYES:FLUSH WITH WATER.SKIN:REMOVE CONTAMINATED CLOTHING;FLUSH
WITH WATER.INHAL:REMOVE TO FRESH AIR.GET MEDICAL ATTENTION.INGEST:IF
CONSCIOUS,INDUCE VOMITING.GET PROMPT QUALIFIED MEDICAL ATTENTION.

===================== Fire Fighting Measures =====================

Flash Point Method: TCC Flash Point:53.0F,11.7C
Lower Limits:2 Upper Limits:2
Extinguishing Media: WATER FOG,ALCOHOL FOAM,DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures: USE A SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE
EQUIPMENT.COOL FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:CONTAINERS MAY RUPTURE FROM PRESSURE BUILD-UP.



NuGeneration Technologies, LLC www.NuGenTec.com
NuGenTec MATERIAL SAFETY DATA SHEET Page 2 of 6
6850-00-826-0981 Updated: Feb 24, 2007

================== Accidental Release Measures ==================

Spill Release Procedures: WARNING! FLAMMABLE. ELIMINATE IGNITION
SOURCES. GROUND HANDLING EQUIPMENT. USE RESPIRATORY AND PROTECTIVE
EQUIPMENT. SOAK UP WITH CLAY,SAND OR OTHER NON-COMBUSTIBLE INERT
ADSORBANT; PLACE IN AN APPROPRIATE CONTAINER FOR DISPOSAL.
Neutralizing Agent: NONE

====================== Handling and Storage ======================

Handling and Storage Precautions:KEEP AWAY FROM HEAT,SPARKS AND FLAMES.
Other Precautions:DO NOT STORE OR HANDLE IN ALUMINUM EQUIPMENT ABOVE
120F.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A SELF-CONTAINED BREATHING APPARATUS.
Ventilation:LOCAL VENTILATION AT THE WORKSITE;MECHANICAL(GENERAL)
VENTILATION TO MAINTAIN TLV/PEL.
Protective Gloves:CHEMICALLY RESISTANT.
Eye Protection:GOGGLES
Other Protective Equipment:CLOTHING TO MINIMIZE SKIN CONTACT.EYE WASH
AND SAFETY SHOWERS SHOULD BE AVAILABLE.
Work Hygienic Practices:WASH HANDS.SEPERATE WORK CLOTHES FROM STREET CLOTHES.
LAUNDER WORK CLOTHES BEFORE REUSE.KEEP FOOD OUT OF THE WORK AREA.
Supplemental Safety and Health - NONE

================== Physical/Chemical Properties ==================

HCC:F2
Boiling Pt:B.P. Text:180F,82C
Melt/Freeze Pt:M.P/F.P Text:-127F,-88C
Vapor Pres:33
Vapor Density:2.1
Spec Gravity:0.8
Evaporation Rate & Reference:1.4
Solubility in Water:LIQUID PART SOLUBLE
Appearance and Odor:EMULSION;MILKY WHITE;MILD ODOR

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.DO NOT STORE OR HANDLE IN ALUMINUM CONTAINERS.
Stability Condition to Avoid:HEAT,SPARKS,FLAME,TEMPERATURES ABOVE 120F
Hazardous Decomposition Products:CARBON MONOXIDE AND UNIDENTIFIED ORGANIC COMPOUNDS.

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSE AS IGNITABLE HAZARDOUS WASTE IN
ACCORDANCE WITH FEDERAL,STATE AND LOCAL REGULATIONS.

NuGenTec provides the information contained herein in good faith but makes no representation as to its comprehensiveness or accuracy.
This document is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using
this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a
particular purpose. NUGENTEC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE
INFORMATION SET FORTH HEREIN OR THE PRODUCT TO WHICH THE INFORMATION REFERS. ACCORDINGLY, NUGENTEC WILL NOT
BE RESPONSIBLE FOR DAMAGES RESULTING FROM USE OF OR RELIANCE UPON THIS INFORMATION.


NuGeneration Technologies, LLC www.NuGenTec.com
NuGenTec MATERIAL SAFETY DATA SHEET Page 3 of 6
6850-00-826-0981 Updated: Feb 24, 2007

PENETRANT -- 6850-00-826-0981
===================== Product Identification =====================

Product ID: PENETRANT
MSDS Date: 03/18/2005
FSC:6850
Kit Part: B
MSDS Number: 826-0981
P/N: NGT-826-0981

============= Composition/Information on Ingredients =============

Ingred Name: HYDRO-TREATED MIDDLE PETROLEUM DISTILLATE
CAS:64742-46-7
RTECS #:JN9379645
Other REC Limits: NONE RECOMMENDED
OSHA PEL:5 MG/M3 OIL MIST
ACGIH TLV:5 MG/M3 OIL MIST

===================== Hazards Identification =====================

LD50 LC50 Mixture: TLV=5MG/M3 (PETROLEUM HYDROCARBONS)
Routes of Entry: Inhalation: YES Skin:YES Ingestion:YES
Reports of Carcinogenicity: NTP: NO IARC: NO OSHA: NO
Health Hazards Acute and Chronic:EYES:PRESUMED
NON-IRRITATING.SKIN:SLIGHTLY IRRITATING.INGEST:IRRITATES GI
TRACT.MAY CAUSE LUNG DAMAGE IF VOMITED AFTER SWALLOWING.INHAL:MILD
IRRITATION TO THE UPPER RESPIRATORY TRACT.
Explanation of Carcinogenicity: THERE ARE NO INGREDIENTS ABOVE 0.1%
WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure: INGEST: VOMITING. SKIN: IRRITATION.
Medical Cond Aggravated by Exposure: PREEXISTING CONDITIONS AFFECTING
THE SKIN AND RESPIRATORY SYSTEM.

======================= First Aid Measures =======================

First Aid: EYES: FLUSH WITH WATER. SKIN: FLUSH WITH WATER; WASH WITH SOAP
AND WATER. INHAL: REMOVE TO FRESH AIR. GIVE OXYGEN OR ARTIFICIAL
RESPIRATION IF NEEDED. INGEST: DO NOT INDUCE VOMITING! GET PROMPT
QUALIFIED MEDICAL ATTENTION.

===================== Fire Fighting Measures =====================

Flash Point Method: PMCC
Flash Point:188F,87C
Extinguishing Media: WATER FOG,FOAM,DRY CHEMICAL OR CARBON DIOXIDE.DO
NOT USE A DIRECT STREAM OF WATER.
Fire Fighting Procedures: MATERIEL WILL NOT BURN UNLESS PREHEATED.USE A
SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard: MANUFACTURER STATES NONE.

================== Accidental Release Measures ==================

Spill Release Procedures: SOAK UP WITH CLAY,SAND OR OTHER
NON-COMBUSTIBLE INERT ADSORBENT; PLACE IN AN APPROPRIATE CONTAINER
FOR DISPOSAL.
Neutralizing Agent:NONE


NuGeneration Technologies, LLC www.NuGenTec.com
NuGenTec MATERIAL SAFETY DATA SHEET Page 4 of 6
6850-00-826-0981 Updated: Feb 24, 2007


====================== Handling and Storage ======================

Handling and Storage Precautions: KEEP AWAY FROM HEAT, FLAMES AND
OXIDIZING MATERIALS.
Other Precautions: NONE

============= Exposure Controls/Personal Protection =============

Respiratory Protection: WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A SELF-CONTAINED BREATHING APPARATUS.
Ventilation: LOCAL VENTILATION AT THE WORKSITE; MECHANICAL(GENERAL)
VENTILATION TO MAINTAIN TLV/PEL.
Protective Gloves:CHEMICALLY RESISTANT
Eye Protection:NO SPECIAL REQUIRENENTS
Other Protective Equipment:CLOTHING TO MINIMIZE SKIN CONTACT.
Work Hygienic Practices:WASH HANDS.SEPERATE WORK CLOTHES FROM STREET
CLOTHES.LAUNDER WORK CLOTHES BEFORE REUSE.KEEP FOOD OUT OF THE WORK
AREA.
Supplemental Safety and Health
FORMULA CHANGE FROM SAME NSN. THIS PART OF A 3 PART KIT.

================== Physical/Chemical Properties ==================

HCC:V4
Boiling Pt:B.P. Text:>400F,>204C
Melt/Freeze Pt:M.P/F.P Text:-75F,-59C
Spec Gravity:0.86
Solubility in Water: INSOLUBLE
Appearance and Odor: LIQUID; RED-PURPLE; HYDROCARBON ODOR.

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid: YES
OXIDIZING MATERIALS.
Stability Condition to Avoid: HEAT AND OPEN FLAMES.
Hazardous Decomposition Products: CARBON MONOXIDE AND OTHER UNIDENTIFIED
ORGANIC COMPOUNDS.

==================== Disposal Considerations ====================

Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.

NuGenTec provides the information contained herein in good faith but makes no representation as to its comprehensiveness or accuracy.
This document is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using
this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a
particular purpose. NUGENTEC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE
INFORMATION SET FORTH HEREIN OR THE PRODUCT TO WHICH THE INFORMATION REFERS. ACCORDINGLY, NUGENTEC WILL NOT
BE RESPONSIBLE FOR DAMAGES RESULTING FROM USE OF OR RELIANCE UPON THIS INFORMATION.




NuGeneration Technologies, LLC www.NuGenTec.com
NuGenTec MATERIAL SAFETY DATA SHEET Page 5 of 6
6850-00-826-0981 Updated: Feb 24, 2007

REMOVER -- 6850-00-826-0981
===================== Product Identification =====================

Product ID: REMOVER
MSDS Date:03/18/2005
FSC:6850
Kit Part: C
MSDS Number: 826-0981
P/N: NGT-826-0981

============= Composition/Information on Ingredients =============

Ingred Name:NAPHTHA, MEDIUM ALIPHATIC CAS:64742-88-7
Other REC Limits:NONE RECOMMENDED
OSHA PEL:100 PPM ACGIH TLV:100 PPM

===================== Hazards Identification =====================

LD50 LC50 Mixture:TLV=200PPM (ALIPHATIC PET.DISTILLATES)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:MINIMALLY
IRRITATING.SKIN:SLIGHTLY IRRITATING.INHAL:VAPOR CAN IRRITATE
NOSE,THROAT AND RESPIRATORY TRACT AND CAUSE CNS DEPRESSION.
Explanation of Carcinogenicity:THERE ARE NO INGREDIENTS ABOVE 0.1%
WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure:INHAL:IRRITATION OF THE EYES,SKIN,NOSE,THROAT
OR RESPIRATORY TRACT.GIDDINESS,HEADACHE.INGEST:VOMITING.
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS OF THE
EYES,SKIN AND RESPIRATORY DISORDERS MAY BE AGGRAVATED BY EXPOSURE
TO THIS PRODUCT.

======================= First Aid Measures =======================

First Aid: EYES: FLUSH WITH WATER. SKIN: REMOVE CONTAMINATED CLOTHING; FLUSH WITH
WATER. INHAL: REMOVE TO FRESH AIR. GIVE OXYGEN OR ARTIFICIAL RESPIRATION IF NEEDED.
INGEST: DO NOT INDUCE VOMITING. GET PROMPT QUALIFIED MEDICAL ATTENTION.

===================== Fire Fighting Measures =====================

Flash Point Method:TCC
Flash Point:140F,60C
Lower Limits:1
Upper Limits:6
Extinguishing Media:WATER FOG,FOAM,DRY CHEMICAL,CARBON DIOXIDE.DO NOT
USE A DIRECT STREAM OF WATER.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.COOL FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:PRESSURE BUILD-UP COULD RUPTURE CONTAINER.

================== Accidental Release Measures ==================

Spill Release Procedures: ELIMINATE SOURCES OF IGNITION. WEAR PROTECTIVE
CLOTHING. SOAK UP WITH CLAY, SAND OR OTHER ADSORBANT; PLACE IN AN
APPROPRIATE CONTAINER FOR DISPOSAL.
Neutralizing Agent: NONE



NuGeneration Technologies, LLC www.NuGenTec.com
NuGenTec MATERIAL SAFETY DATA SHEET Page 6 of 6
6850-00-826-0981 Updated: Feb 24, 2007

====================== Handling and Storage ======================

Handling and Storage Precautions:KEEP AWAY FROM HEAT SPARKS AND
FLAMES.KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:USE WITH ADEQUATE VENTILATION.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A SELF-CONTAINED BREATHING APPARATUS.
Ventilation:LOCAL VENTILATION AT THE WORKSITE; MECHANICAL(GENERAL)
VENTILATION TO MAINTAIN TLV/PEL.
Protective Gloves:CHEMICALLY RESISTANT
Eye Protection:SAFETY GLASSES;GOGGLES
Other Protective Equipment:CLOTHING TO AVOID SKIN CONTACT.
Work Hygienic Practices:WASH HANDS.SEPERATE WORK CLOTHES FROM STREET
CLOTHES.LAUNDER WORK CLOTHES BEFORE REUSE.KEEP FOOD OUT OF THE WORK
AREA.
Supplemental Safety and Health
FORMULA CHANGE FROM SAME NSN;PNIND-G.THIS IS PART OF A 3 PART KIT.

================== Physical/Chemical Properties ==================

HCC:F4
Boiling Pt:B.P. Text:355F,179C
Vapor Pres:5MM@68F
Vapor Density: 5.4
Spec Gravity:0.77
Evaporation Rate & Reference:<0.1
Solubility in Water: NEGLIGIBLE
Appearance and Odor:LIQUID;LIGHT COLOR;MINTY OR HYDROCARBON ODOR

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT,FLAMES.
Hazardous Decomposition Products: CARBON MONOXIDE AND UNIDENTIFIED
ORGANIC COMPOUNDS.

==================== Disposal Considerations ====================

Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.

NuGenTec provides the information contained herein in good faith but makes no representation as to its comprehensiveness or accuracy.
This document is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using
this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a
particular purpose. NUGENTEC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE
INFORMATION SET FORTH HEREIN OR THE PRODUCT TO WHICH THE INFORMATION REFERS. ACCORDINGLY, NUGENTEC WILL NOT
BE RESPONSIBLE FOR DAMAGES RESULTING FROM USE OF OR RELIANCE UPON THIS INFORMATION.




NuGeneration Technologies, LLC www.NuGenTec.com

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
nugentec_com---aquaklean_ef_115-nn_-_msds.asp 111-76-2 1310-73-2
nugentec_com---aquaklean_ef_145_-_msds.asp 64-02-8 1310-73-2
nugentec_com---aquaklean_green_-_msds.asp N/A
nugentec_com---aquaklean_ns_msds.asp 34590-94-8
nugentec_com---aquaklean__hds_40_-_msds.asp 13472-30-5 34274-30-1 27177-77-1
nugentec_com---aquaklean__hds_50_-_msds.asp 34274-30-1 27177-77-1
nugentec_com---aquakwik_lf6x_msds_windshield_washer_fliud_concentrate_20f_grade.asp 67-63-0
nugentec_com---autodishwash_liquid.asp 1310-73-2
nugentec_com---autodishwash_powder.asp 13472-30-5 7722-88-5
nugentec_com---automobile_polish_wax_msds_7930-00-985-6750.asp 7930-00-9 8052-41-3
nugentec_com---bug-kill_-_msds_new_user_v1.asp 4719-04-4 7732-18-5
nugentec_com---bug-kill_onyxide_200_msds.asp 4719-04-4 7732-18-5
nugentec_com---burnishing_fluid.asp N/A
nugentec_com---calcium_chloride_94-97_superflake--6810-00-082-2644_msds.asp 6810-00-0 10043-52-4
nugentec_com---car-wax_msds_7930-00-281-3267.asp 7930-00-2 8052-41-3
nugentec_com---caustic_soda_sodium_hydroxide_anhydrous_msds_6810-00-270-8177_6810-00-174-6581.asp 1310-73-2 6810-00-2
nugentec_com---citra-soy_2.asp 68647-72-3 67784-80-9 68603-25-8
nugentec_com---citraklean_msds.asp 5989-27-5 34590-94-8 27177-77-1 533-96-0 68603-25-8
nugentec_com---citrasolv.asp 68647-72-3
nugentec_com---citrasolv_plus.asp 68647-72-3 68603-25-8
nugentec_com---citric_acid_50.asp 77-92-9
nugentec_com---citruskleen_100-msds.asp 68647-72-3
nugentec_com---corrosion_inhibitor_msds_6850-00-142-9389.asp 6850-00-1 71-55-6 127-18-4 628-63-7 107-41-5 8008-20-6
nugentec_com---developer_penetrant_remover_msds_6850-00-826-0981.asp 6850-00-8 67-63-0
nugentec_com---dishmachine_de-limer_and_brightner.asp 7647-01-1 7664-39-3
nugentec_com---disinfectant_general_purpose_msds_6840-00-782-2691.asp 6840-00-7
nugentec_com---final_rinse_rp_-_msds.asp 7632-00-0 68603-25-8
nugentec_com---foam_rug_and_upholstery_cleaner_msds_7930-00-724-9556.asp 7930-00-7
nugentec_com---glass_and_window_cleaner_-_msds.asp 67-63-0
nugentec_com---grease_and_carbon_remover_-_msds.asp 1310-73-2 27177-77-1 68603-25-8 111-76-2
nugentec_com---grease_cutter_2_-_msds.asp 1310-73-2 27177-77-1 68603-25-8 111-76-2
nugentec_com---grease_cutter_3_-_msds.asp 111-76-2 1310-73-2 27177-77-1 68603-25-8 13472-30-5
nugentec_com---high_foam_truck_wash.asp 497-19-8 68603-25-8
nugentec_com---metal_polish_msds_7930-00-266-7136.asp 7930-00-2
nugentec_com---methyl_orange_indicator_solution_msds.asp 547-58-0
nugentec_com---neutralizer_1_-_msds.asp 7664-93-9 7732-18-5
nugentec_com---nubcr-msds.asp 112-34-5 141-43-5 13472-30-5
nugentec_com---nubrite_44s_-_msds.asp 7697-37-2 7664-39-3
nugentec_com---nubrite_55l_-_msds.asp 7697-37-2 7664-39-3
nugentec_com---nubrite_b_17.asp 34590-94-8
nugentec_com---nubrite_b_23.asp 141-43-5 69227-22-1
nugentec_com---nubrite_b_23_msds.asp 141-43-5 69227-22-1
nugentec_com---nubrite_b_30.asp N/A
nugentec_com---nubrite_c30-msds.asp 77-92-9 68603-25-8 7732-18-5
nugentec_com---nubrite_c50-msds.asp 77-92-9 68603-25-8 7732-18-5
nugentec_com---nubrite_ck_-_msds.asp 7664-38-2 34590-94-8 68603-25-8 7732-18-5
nugentec_com---nubrite_cp_3.asp 141-43-5 77-92-9
nugentec_com---nubrite_plasti-prep.asp 141-43-5
nugentec_com---nubuff_2_msds_non-regulated_material.asp 9016-45-9 7953-76-8 7732-18-5
nugentec_com---nuetch_e2_-_msds.asp 1310-73-2

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC