NuGenTec
NuBrite CP 3 Page 1 of 7
PRD Number: SCH 204 ___ May 30, 2007
MATERIAL SAFETY DATA SHEET
1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Product Identification
----------------------
Product Name: NuBrite CP 3
Product Number: SCH204
CAS Number: Blend
Company Identification
----------------------
NuGeneration Technologies, LLC www.nugentec.com
100 Professional Center Drive Suite 101
Rohnert Park, CA 94928 USA
(707) 820-4080 (For product information)
1-800-424-9300 or 1-202-483-7616 (CHEMTREC) (For emergencies)
SPECIAL NOTES:
This product is Biodegradable. This product contains NO Chelates.
2. COMPOSITION/INFORMATION ON INGREDIENTS
100.0% NuBrite CP 3
CONTAINING:
HAZARDOUS AND/OR REGULATED COMPONENTS
Chemical Name Amount CAS Number
------------- -------- ----------
MONOETHANOLAMINE < 8.0 % 141-43-5
CITRIC ACID < 25.0 % 77-92-9
NON-HAZARDOUS COMPONENTS
Chemical Name Amount CAS Number
------------- -------- ----------
NONIONIC SURFACTANT BLEND < 12.0 % TRADESECRET
(See Section 8 for exposure guidelines)
(See Section 15 for regulatory information)
HAZARDS DISCLOSURE
This product contains hazardous materials as defined by the OSHA Hazard
Communication Standard 29 CFR 1910.1200.
As defined under Sara 311 and 312, this product contains no known
hazardous materials.
NuGenTec
NuBrite CP 3 Page 2 of 7
PRD Number: SCH 204 ___ May 30, 2007
MISCELLANEOUS:
Contains Citric Acid.
3. HAZARDS IDENTIFICATION
***************** EMERGENCY OVERVIEW *****************
* *
* CAUTION *
* *
* Can cause skin and eye irritation. *
* *
**********************************************************
HMIS Rating - Health: 1
Flammability: 0
Reactivity: 0
Personal Protection Index: C
NFPA Rating - Health: 1
Flammability: 0
Reactivity: 0
Special Hazard: None
NFPA/HMIS Definitions: (0-Least, 1-Slight, 2-Moderate, 3-High,
4-Extreme). These values are obtained using the guidelines or published
evaluations prepared by the National Fire Protection Association (NFPA) or
the National Paint and Coating Association (for HMIS ratings).
POTENTIAL HEALTH EFFECTS
EYE:
Contact may cause eye irritation.
SKIN:
Contact may causes skin irritation.
INHALATION:
No known hazards in normal industrial use.
INGESTION:
Ingestion is not considered a potential route of exposure. May cause
diarrhea, nausea, abdominal cramps.
SIGNS AND SYMPTOMS OF EXPOSURE:
If exposed areas are flushed promptly and thoroughly with water, there
should be little or no harm.
CARCINOGENICITY INFORMATION:
No known cancer hazards.
NuGenTec
NuBrite CP 3 Page 3 of 7
PRD Number: SCH 204 ___ May 30, 2007
MISCELLANEOUS:
Slippery, can cause falls if walked on.
4. FIRST AID MEASURES
EYE CONTACT FIRST AID:
Flush eye with water for 15 minutes. Get medical attention if irritation
develops or persists.
SKIN CONTACT FIRST AID:
Immediately flush skin with plenty of water. Remove contaminated clothing
and shoes. Get medical attention if irritation develops or persists.
INHALATION FIRST AID:
Although this product is not known to cause respiratory problems, if
breathing is difficult, remove to fresh air and provide oxygen.
INGESTION FIRST AID:
Get medical attention immediately. Do not induce vomiting.
STATEMENT OF PRACTICAL TREATMENT:
Always have plenty of water available for first aid.
NOTES TO PHYSICIAN:
Treat patient symptomatically.
5. FIRE FIGHTING MEASURES
FLAMMABLE PROPERTIES
COC Flash Point: None
TCC Flash Point: None
Autoignition Temperature: None
FLAMMABLE LIMITS IN AIR
LEL: None
UEL: None
EXTINGUISHING MEDIA:
Will not burn.
FIRE FIGHTING INSTRUCTIONS:
Contaminated extinguishing water must be disposed of in accordance with
applicable regulations.
6. ACCIDENTAL RELEASE MEASURES
SAFEGUARDS (PERSONNEL):
Protect skin and eyes from exposure.
NuGenTec
NuBrite CP 3 Page 4 of 7
PRD Number: SCH 204 ___ May 30, 2007
INITIAL CONTAINMENT:
Contain spilled material.
LARGE SPILLS PROCEDURE:
Forms smooth, slippery surfaces on floors, posing an accident risk.
Dilute with water and wash to waste water treatment system. Large spills
may be neutralized with dilute alkaline solutions of soda ash, or lime.
Treat or dispose of waste material in accordance with all local,
state/provincial, and national requirements.
SMALL SPILLS PROCEDURE:
Floor may become slippery. Dispose into waste water treatment facility.
7. HANDLING AND STORAGE
RECOMMENDED STORAGE TEMPERATURE
Minimum: 4.4 C (39.9 F)
Maximum: 48.9 C (120.0 F)
HANDLING (PERSONNEL):
Avoid contact with eyes, skin, and clothing.
STORAGE PRECAUTIONS:
Keep from freezing. Keep container closed when not in use.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS:
No special ventilation requirements.
EYE / FACE PROTECTION REQUIREMENTS:
When splashing of the material may occur, chemical goggles and a face
shield are recommended.
SKIN PROTECTION REQUIREMENTS:
Wear protective gloves to minimize skin contamination.
RESPIRATORY PROTECTION REQUIREMENTS:
Under normal use conditions, with adequate ventilation, no special
handling equipment is required.
MISCELLANEOUS:
Where an apron and protective clothing.
EXPOSURE GUIDELINES:
Monoethanolamine
OSHA TWA: 3 ppm
OSHA STEL: 6 ppm
NuGenTec
NuBrite CP 3 Page 5 of 7
PRD Number: SCH 204 ___ May 30, 2007
9. PHYSICAL AND CHEMICAL PROPERTIES
FORM .....................: Liquid
COLOR ....................: yellow
ODOR .....................: Mild
BOILING POINT ............: >212 F
SOLUBILITY IN WATER ......: Complete
SPECIFIC GRAVITY .........: 1.074 (Water = 1)
BULK DENSITY .............: 8.96
MELTING/FREEZING POINT ...: 32 F
PH .......................: 4.0
% VOLATILES ..............: 0.0 %
PH (1% B.V.) .............: 4.2
10. STABILITY AND REACTIVITY
STABILITY:
Stable.
POLYMERIZATION:
Hazardous polymerization will not occur.
INCOMPATIBILITY WITH OTHER MATERIALS:
None known.
DECOMPOSITION:
Decomposition will not occur if handled and stored properly.
CONDITIONS TO AVOID:
This material is safe under normal storage and handling conditions.
11. TOXICOLOGICAL INFORMATION
EYE EFFECTS:
Contact may cause eye irritation.
SKIN EFFECTS:
Contact may cause slight skin irritation.
ACUTE INHALATION EFFECTS:
No know hazards in normal industrial use.
12. ECOLOGICAL INFORMATION
No information available.
13. DISPOSAL CONSIDERATIONS
WASTE DISPOSAL:
Treat or dispose of waste material in accordance with all local,
NuGenTec
NuBrite CP 3 Page 6 of 7
PRD Number: SCH 204 ___ May 30, 2007
state/provincial, and national requirements. For additional waste
disposal information contact your local NuGenTec representative at (888)
99-NuGen. Uncleaned empty containers should be disposed of in the same
manner as the contents.
CONTAMINATED MATERIALS:
Wash contaminated clothing before reuse.
CONTAINER DISPOSAL:
Clean out containers prior to disposal.
14. TRANSPORTATION INFORMATION
PRODUCT LABEL .............: NuBrite CP 3
D.O.T. SHIPPING NAME ......: Cleaning Compound
TECHNICAL SHIPPING NAME ...: Non-Regulated Material
D.O.T. HAZARD CLASS .......: Non-Hazardous
UN NUMBER .................: N/A
PRODUCT RQ (LBS) ..........: N/A
D.O.T. LABEL ..............: NOBIN Non-Hazardous
D.O.T. PLACARD ............: N/A
BULK CLASS ................: N/A
PACKAGE CLASS .............: 55
MISCELLANEOUS:
Export Classification, organic surface active agents (other than soap),
washing preparations and cleaning preparations, schedule B # 3402.90.5030.
15. REGULATORY INFORMATION
EEC Symbols and Indications of Danger:
None
WHMIS Hazard Symbols:
None
Canadian Disclosure List
Citric Acid (77-92-9)
MISCELLANEOUS INFORMATION:
This material or all of its components are listed on the Inventory of
Existing Chemical Substances under the Toxic Substance Control Act
(TSCA). This material or all of its components are listed on the
Canadian Domestic Substances List (DSL). This material or all of its
components are listed on the Inventory of Existing Chemical Substances
under the Toxic Substance Control Act (TSCA).
NuGenTec
NuBrite CP 3 Page 7 of 7
PRD Number: SCH 204 ___ May 30, 2007
16. OTHER INFORMATION
PREPARED BY .......: Donato Polignone
APPROVAL DATE .....: May 30, 2007
SUPERCEDES DATE ...: July 10, 2002
PRD NUMBER ........: SCH204 (Official Copy)
ADDITIONAL INFORMATION:
The data in this Material Safety Data Sheet relates only to the specific
material designated herein. It does not relate to use in combination
with any other material or in any process.
**********************************************************************
This information is furnished without warranty, expressed or implied,
except that it is accurate to the best knowledge of NuGeneration
Technologies, LLC. The data on this sheet are related only to the
specific material designated herein. NuGeneration Technologies, LLC
assumes no legal responsibility for use or reliance upon these data.
**********************************************************************
END OF MSDS
**********************************************************************
|