Guanidine Thiocyanate
Material Safety Data Sheet
Cat.# 9420 - 9422
PHYSICAL DATA
Appearance and Odor White Crystals
o
Boiling Point 116 C
3
Specific Gravity 1.288 cm
o
Solubility in H2O Soluble/ 1600 g/l(at 25 C)
CAS Number 593-84-0
FIRE AND EXPLOSION HAZARD DATA
Flash Point Does Not Flash
Flammable Limits in Air(% by Volume) No Data
Extinguishing Media Water, CO2, Foam, Dry Chemical
Special Fire Fighting Wear self-contained breathing apparatus and protective clothing. Use
water to cool exposed containers.
Unusual Fire/Explosion Hazards Irritating and/or toxic gases or fumes may be generated by thermal
decomposition or combustion. Closed containers may explode when
exposed to extreme heat.
HEALTH HAZARD DATA
Effects of Overexposure Acute overexposure may cause irritation.
Emergency First Aid Procedures Notify physician immediately. Wash affected area with soap and water.
Remove contaminated clothing. Remove to fresh air. Irrigate eyes for at
least 15 minutes. If ingested, induce vomiting.
REACTIVITY DATA
Stability Stable
Incompatibility Strong acids, bases or oxidants
Hazardous Decomposition Products Acrid fumes. Oxides of carbon, sulfur and nitrogen.
Hazardous Polymerization Will not occur.
SPILL OR LEAK PROCEDURES
If released or spilled Ventilate area. Prevent dust buildup. Place in containers with a lid. Wash
spill area with copious amounts of water.
Waste Disposal Method Dispose according to federal and local regulations.
SPECIAL PROTECTION INFORMATION
Respiratory Protection Use NIOSH approved respirator as needed
Ventilation Lab Hood as appropriate
Protective Gloves General lab gloves
Eye Protection Use general lab eye protection-goggles
Precautionary Labeling Avoid contact with skin, eyes and clothing.
Handling and Storage Considerations Laboratory aprons and gloves. Store at room temperature.
This bulletin is for your guidance and is based upon information and tests believed to be reliable. Ambion makes no guarantee of the accuracy or completeness of
the data and shall not be liable for any damages thereto. The data are offered solely for your consideration, investigation, and verification. These suggestions
should not be confused with either state, municipal, or insurance requirements, or with national safety codes and constitute no warranty. Any use of these data and
information must be determined by the user to be in accordance with applicable federal, state, and local regulations.042000 msds\guscn.msd
Ambion, Inc. 鈥? 2130 Woodward St. 鈥? Austin, TX USA 78744-1832 鈥? International Tel: +1 512 651 0200
US Toll-free Tel: 800 888 8804 鈥? E-mail: techserv@ambion.com 鈥? www.ambion.com
www.ambion.com/techlib/msds/msds_9420.pdf
|