Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

79-06-1

File Name: ambion_com---msds_9520.asp
       Linear Acrylamide Solution
Material Safety Data Sheet




Cat.# 9520
PHYSICAL DATA
This acrylamide has been linearized by polymerization and therefore, is no longer carcinogenic.
Appearance and Odor Clear, colorless, odorless liquid
o
Boiling Point 98-104 C
Specific Gravity N/A
Solubility in H2O Soluble
CAS Number 79-06-1, 110-26-9

FIRE AND EXPLOSION HAZARD DATA
Flash Point Not flammable
Extinguishing Media Water, CO2, Foam, Dry Chemical
Special Fire Fighting Wear self-contained breathing apparatus and protective clothing.
Fire/Explosion Hazards N/A

HEALTH HAZARD DATA
This acrylamide has been linearized by polymerization and therefore, is no longer carcinogenic.
Effects of Overexposure All overexposure should receive medical immediate attention.
Emergency First Aid Flush affected area with water, use safety shower Remove to fresh air.
Irrigate eyes and skin for at least 15 minutes. Notify physician immediately
and give information concerning exposure, state that you have been exposed
to polymerized acrylamide. (Should not be the same hazardousnous as a
aqueous buffer).

REACTIVITY DATA
Stability Stable
Incompatibility Strong oxidizing agents and high temperatures.
Hazardous Decomp. Products Thermal decomposition may produce CO2 and CO and nitrogen oxides.
Hazardous Polymerization N/A

SPILL OR LEAK PROCEDURES
If released or spilled Absorb with inert material.Wash spill area thoroughly.
Waste Disposal Method Dispose according to federal, local and state regulations.

SPECIAL PROTECTION INFORMATION
Respiratory Protection Not expected to require personal respirator usage.
Ventilation Not expected to require any special ventilation. General lab hood if
necessary.
Protective Gloves Laboratory aprons and gloves.
Eye Protection Use general eye protection-goggles
Precautionary Labeling None




This bulletin is for your guidance and is based upon information and tests believed to be reliable. Ambion makes no guarantee of the accuracy or completeness of the
data and shall not be liable for any damages thereto. The data are offered solely for your consideration, investigation, and verification. These suggestions should not be
confused with either state, municipal, or insurance requirements, or with national safety codes and constitute no warranty. Any use of these data and information must be
determined by the user to be in accordance with applicable federal, state, and local regulations.042000 msds\linacryl.msd




Ambion, Inc. 鈥? 2130 Woodward St. 鈥? Austin, TX USA 78744-1832 鈥? International Tel: +1 512 651 0200
US Toll-free Tel: 800 888 8804 鈥? E-mail: techserv@ambion.com 鈥? www.ambion.com
www.ambion.com/techlib/msds/msds_9520.pdf

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
ambion_com---msds_7151.asp 75-12-7
ambion_com---msds_7155.asp N/A
ambion_com---msds_7323.asp N/A
ambion_com---msds_7790.asp N/A
ambion_com---msds_7800.asp N/A
ambion_com---msds_8450.asp N/A
ambion_com---msds_8452.asp N/A
ambion_com---msds_8500.asp N/A
ambion_com---msds_8504.asp N/A
ambion_com---msds_8547.asp 75-12-7
ambion_com---msds_8551.asp 107-22-2
ambion_com---msds_8552.asp 75-12-7
ambion_com---msds_8640.asp N/A
ambion_com---msds_8666.asp 75-12-7
ambion_com---msds_8667.asp N/A
ambion_com---msds_8669.asp N/A
ambion_com---msds_8676.asp 75-12-7
ambion_com---msds_8990.asp N/A
ambion_com---msds_9015.asp N/A
ambion_com---msds_9022.asp 79-06-1
ambion_com---msds_9030.asp 79-06-1 57-13-6
ambion_com---msds_9040.asp 39346-81-1
ambion_com---msds_9044.asp N/A
ambion_com---msds_9071.asp 631-61-8
ambion_com---msds_9162.asp 7647-17-8
ambion_com---msds_9342.asp 75-12-7
ambion_com---msds_9420.asp 593-84-0
ambion_com---msds_9462.asp 19165-11-8
ambion_com---msds_9480.asp 7447-41-8 6381-92-6
ambion_com---msds_9515.asp N/A
ambion_com---msds_9520.asp 79-06-1
ambion_com---msds_9570.asp 1132-61-2
ambion_com---msds_9624.asp N/A
ambion_com---msds_9640G.asp 7447-40-7
ambion_com---msds_9690.asp N/A
ambion_com---msds_9710.asp 108-95-2 77-86-1 6381-92-6
ambion_com---msds_9720.asp 108-95-2 67-66-3
ambion_com---msds_9730.asp 108-95-2 67-66-3
ambion_com---msds_9738.asp 108-95-2
ambion_com---msds_9759.asp 7647-14-5
ambion_com---msds_9763.asp 7647-14-5 6132-04-3
ambion_com---msds_9775.asp N/A
ambion_com---msds_9780.asp N/A
ambion_com---msds_9785.asp N/A
ambion_com---msds_9820.asp 151-21-3
ambion_com---msds_9849.asp N/A
ambion_com---msds_9856.asp 77-86-1
ambion_com---msds_9860.asp N/A
ambion_com---msds_9863.asp 77-86-1 10043-35-3
ambion_com---msds_9900.asp 57-13-6

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC