Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

0360-01-1

File Name: cpd_ca---03600_nspremix.asp
CPD庐 NON-SHRINK GROUT (PRE-MIX)
Hole Depth Hole Diameter Load Failure
DESCRIPTION
CPD庐 Non-Shrink Grout is a pre-blended, ready-to-use 125mm (4.89in) 38mm(1.48in) 89.5 kn
cement base grout containing non-ferrous fluidifiers and 190mm (7.41in) 38mm 122.4 kn
anti-shrinkage compounds accurately blended with graded 250mm (9.75in) 38mm 139.8 kn
siliceous aggregate and Portland cement. It is pre-blended
and requires only the addition of water at the job site. Set Time . . . . . . . 6 hours, 10 minutes @ 21掳C (70掳F)
(10 mm/0.39in penetration)
WHERE TO USE
CPD庐 Non-Shrink Grout is used for grouting structural The above information is representative of actual
steel column base plates, anchor bolts, bridge bearing production runs. Independent test results may vary from
seats, machinery bases and reinforced masonry walls. the above by approximately 卤 10%.

BENEFITS APPLICATION
鈥? can be placed in different consistencies ranging from SURFACE PREPARATION
All surfaces that will be in contact with the grout must be
plastic to self-leveling
clean and free of grease, oil, standing water, laitance, loose
鈥? flowability facilitates placement in confirmed areas
material or any other contaminant that could impair
鈥? complete bearing surface contact ensures uniform load
substrate bond. Prior to grouting, foundation concrete
distribution
should be roughened, cleaned and thoroughly wetted down
鈥? no ferrous additives to cause staining
for 12 hours. Free standing water should be blown clear
鈥? expansive agents ensure uniform, consistent expansion
for over one hour just prior to grouting using oil free compressed air.
鈥? excellent freeze-thaw resistance, even if pourable Forms must be rigid and water tight. Construct them with
consistency sides one to two inches above the base plate allowing a
鈥? does not contain corrosive additives, such as calcium 鈥渉ead鈥? of grout to flow to the proper level. Vent high
chloride points to permit the escape of entrapped air. Grout must be
鈥? resistant to oil, some chemicals and moisture placed from one side only and allowed to flow to opposite
form. Use only a minimum amount of water, consistent
with flowability required. Do not exceed 4.0 L of water
PROPERTIES
Compressive Strength (ASTM C109-77, 2" cubes per 25 kg bag of grout (1.06 U.S. gal/55lb). Mix
confined) @ 20掳 C (68掳F) thoroughly and place within an hour of mixing. Keep
grout agitated in mixer at all times. As the grout sets, cure
exposed surfaces with CPD庐 Acrylic Cure & Seal or damp
Flowable*
1 day . . . . . . . . . . . . . . . . . . . . . . 40 MPa (5,800 psi) burlap.
3 days . . . . . . . . . . . . . . . . . . . . . . 51 MPa (7,395 psi) Ideal grouting temperature is 10掳C to 25掳C (50-77掳F).
7 days . . . . . . . . . . . . . . . . . . . . . . 60 MPa (8,700 psi)
28 days . . . . . . . . . . . . . . . . . . . . . 64 MPa (9,280 psi) Cooler temperatures will retard the rate of strength gain in
90 days . . . . . . . . . . . . . . . . . . . . 74 MPa (10,730 psi) all mixes. Keep surrounding concrete and contact steel
above 4.5掳C (40掳F) for at least 72 hours after completion
*150% flow (ASTM C230-90) 4.0L/25kg (1.06 U.S. of grout pour.
gal/55lb).
MIXING AND PLACING
CPD庐 Non-Shrink Grout may be pumped or poured in
Pull Out Tests
Mix Ratio 4L/25 kg (1.06 U.S. gal/55 lb) place. In all cases, no foreign materials are to be added
without first contacting your CPD庐 Technical
Test conducted using a 15mm/0.59in (grade 400) for
epoxy coated rebar. Representative.


0360-01-1105
The following is to be used as a guide. Always use the of such products for any particular purpose.
minimum water required.
CPD庐 makes no warranties with respect to this product,
Flowable - 4L water per 25kg bag (1.06 U.S. gal/55lb)
Non Shrink Concrete Mix expressed or implied, without limitation, the implied
50 kg (110 lb) CPD庐 Non-Shrink Grout warranties of merchantability or fitness for a particular
25 kg (55lb) 10mm (3/8") Pea Gravel purpose.
7-8 L (1.85-2.1 U.S. gal) water (depending on
CPD庐鈥? liability shall be limited in all events to supplying
consistency required) s
sufficient product to re-treat and/or repair the specific area
to which CPD庐 product has been applied. CPD庐 reserves
LIMITATIONS
? do not use in areas of high vibration the right to have the true cause of any difficulty determined
? where chemical attack is possible by accepted test methods. CPD庐 shall have no other
liability, including liability for incidental, consequential or
resultant damages, however caused, whether due to breach
COVERAGE
0.014m鲁 (0.47ft鲁) per 25 kg (55lb) bag (at the maximum of warranty, negligence, or strict liability.
4L (1.06 U.S. gal) water content).
THIS WARRANTY MAY NOT BE MODIFIED OR
EXTENDED BY REPRESENTATIVES OF CPD庐, ITS
STANDARDS
Formulated to comply with U.S. Corps of Engineers DISTRIBUTORS OR DEALERS.
CRD-C621-92 and ASTM C1107-91.
Approved for use on all MTO projects (Ministry of
Transportation).

PACKAGING
25 kg. (55 lb) multi-wall bag.

STORAGE
May be stored short term anywhere under tarp on pallets
as long as the product is kept dry. Dry heated warehouse
storage is recommended for extended storage.

SHELF LIFE
One year from the date of manufacture when stored in
original, unopened package and under normal warehouse
conditions.

SAFETY PRECAUTIONS
Consult Material Safety Data Sheet ( M.S.D.S.) for
specific instructions. MSDS # 4.

WARRANTY
The recommendations made and the information herein is
based on our own and independent laboratory experience,
and is believed to be accurate under controlled conditions.
However, no warranty or guarantee of accuracy is made
because we cannot cover every possible application of
product nor anticipate every variation encountered in
weather conditions, job-conditions, methods used and
types of surfaces on which the product is applied. The
users shall make their own tests to determine the suitability

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
cpd_ca---03150_pvc1.asp N/A
cpd_ca---03300_floorhdr.asp 0330-01-0
cpd_ca---03390_acryliccssilane.asp N/A
cpd_ca---03390_chlorrubber.asp N/A
cpd_ca---03390_clrgrncuring.asp 0339-01-1
cpd_ca---03390_clrmason&conc.asp 0339-11-1
cpd_ca---03390_cs20wb.asp N/A
cpd_ca---03390_cs21.asp N/A
cpd_ca---03390_cs25.asp N/A
cpd_ca---03390_cssolvent.asp N/A
cpd_ca---03390_hardcure.asp 0339-13-1
cpd_ca---03540_topcrete_sl.asp N/A
cpd_ca---03600_cipaditee500grout.asp N/A
cpd_ca---03600_nsdrypk.asp 0360-04-1
cpd_ca---03600_nsfibre.asp N/A
cpd_ca---03600_nshes.asp 0360-03-1
cpd_ca---03600_nspremix.asp 0360-01-1
cpd_ca---03900_cipadite35.asp N/A
cpd_ca---03900_latexconad.asp N/A
cpd_ca---03900_latex_adhesive.asp N/A
cpd_ca---03920_10minuteset.asp 0392-02-1
cpd_ca---03920_20minuteset.asp 0392-01-1
cpd_ca---03920_aquacrete.asp N/A
cpd_ca---03920_fastcretehs.asp N/A
cpd_ca---03920_fastcreteoh.asp N/A
cpd_ca---03920_fastcreteultra.asp N/A
cpd_ca---03920_rapidcrete.asp N/A
cpd_ca---03920_rapidcrete_fiber.asp 0392-09-1
cpd_ca---03920_topcrete.asp N/A
cpd_ca---03930_cipadite20.asp N/A
cpd_ca---03930_cipadite25.asp 0393-05-1
cpd_ca---03930_cipaditegel15.asp 0393-03-1
cpd_ca---03930_epoxflexltgrout.asp N/A
cpd_ca---03930_superplug.asp 0393-01-1
cpd_ca---04060_stovefurnace.asp N/A
cpd_ca---07190_cipadames40.asp N/A
cpd_ca---07190_paver.asp N/A
cpd_ca---07190_saltguard.asp 0719-02-1
cpd_ca---07190_saltultra.asp N/A
cpd_ca---07920_cipadame-13.asp N/A
cpd_ca---07920_clscellfoam.asp N/A
cpd_ca---09600_cipadeckblsystem.asp N/A
cpd_ca---09600_cipadeckmembrane100.asp N/A
cpd_ca---09600_cipadeckmembrane60lt.asp N/A
cpd_ca---09600_cipadeckmr.asp N/A
cpd_ca---09600_cipadeckt-coat.asp N/A
cpd_ca---09600_cipaditecondprimer.asp 0960-05-1
cpd_ca---09600_cipaditeprimhi.asp N/A
cpd_ca---09600_cipaditest.asp N/A
cpd_ca---09600_cipadomeconductive.asp N/A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC